Skip to contentSkip to conversation

dt-bindings: hwmon: pwm-fan: Document start from dead stop properties

PATCH Superseded Marek Vasut 4 participants 12 messages Nov 5, 2024 – Nov 6, 2024

Subsystems (2)

v1 of 3 Superseded Latest is v3 →

lore
Share & tools
lore
#0 lore raw

PATCH 1/2 dt-bindings: hwmon: pwm-fan: Document start from dead stop properties

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]

---
 Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 +++++++++++
 1 file changed, 11 insertions(+)
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +11 -0
index 4e5abf7580cc6..f1042471b5176 100644
@@ -31,6 +31,17 @@ properties:
       it must be self resetting edge interrupts.
     maxItems: 1
 
+  fan-dead-stop-start-percent:
+    description:
+      Minimum fan RPM in percent to start from dead stop.
+    minimum: 0
+    maximum: 100
+
+  fan-dead-stop-start-usec:
+    description:
+      Time to wait in microseconds after start from dead stop.
+    $ref: /schemas/types.yaml#/definitions/uint32
+
   pulses-per-revolution:
     description:
       Define the number of pulses per fan revolution for each tachometer
Signature · 1 line
2.45.2
#1 lore raw

PATCH 2/2 hwmon: (pwm-fan) Introduce start from dead stop handling

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which need to start at higher PWM duty cycle first and can slow down next.

Introduce two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

Adjust the PWM setting code such that if the PWM duty cycle is below the minimum duty cycle needed by the fan to spin up from dead stop, then first set the PWM duty cycle to the minimum duty cycle needed by the fan to spin up from dead stop, then wait the time necessary for the fan to spin up from dead stop, and finally set the PWM duty cycle to the one desired by user.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]

---
 drivers/hwmon/pwm-fan.c | 33 ++++++++++++++++++++++++++++++++-
 1 file changed, 32 insertions(+), 1 deletion(-)
drivers/hwmon/pwm-fan.c +32 -1
index c434db4656e7d..264b7ddf8bb40 100644
@@ -7,6 +7,7 @@
  * Author: Kamil Debski <[email protected]>
  */
 
+#include <linux/delay.h>
 #include <linux/hwmon.h>
 #include <linux/interrupt.h>
 #include <linux/mod_devicetable.h>
@@ -60,6 +61,9 @@ struct pwm_fan_ctx {
 
 	struct hwmon_chip_info info;
 	struct hwmon_channel_info fan_channel;
+
+	u64 pwm_duty_cycle_from_dead_stop;
+	u32 pwm_usec_from_dead_stop;
 };
 
 /* This handler assumes self resetting edge triggered interrupt. */
@@ -199,7 +203,9 @@ static int pwm_fan_power_off(struct pwm_fan_ctx *ctx, bool force_disable)
 static int  __set_pwm(struct pwm_fan_ctx *ctx, unsigned long pwm)
 {
 	struct pwm_state *state = &ctx->pwm_state;
+	unsigned long final_pwm = pwm;
 	unsigned long period;
+	bool update = false;
 	int ret = 0;
 
 	if (pwm > 0) {
@@ -208,11 +214,22 @@ static int  __set_pwm(struct pwm_fan_ctx *ctx, unsigned long pwm)
 			return 0;
 
 		period = state->period;
-		state->duty_cycle = DIV_ROUND_UP(pwm * (period - 1), MAX_PWM);
+		update = state->duty_cycle < ctx->pwm_duty_cycle_from_dead_stop;
+		if (update)
+			state->duty_cycle = ctx->pwm_duty_cycle_from_dead_stop;
+		else
+			state->duty_cycle = DIV_ROUND_UP(pwm * (period - 1), MAX_PWM);
 		ret = pwm_apply_might_sleep(ctx->pwm, state);
 		if (ret)
 			return ret;
 		ret = pwm_fan_power_on(ctx);
+		if (!ret && update) {
+			pwm = final_pwm;
+			state->duty_cycle = DIV_ROUND_UP(pwm * (period - 1), MAX_PWM);
+			usleep_range(ctx->pwm_usec_from_dead_stop,
+				     ctx->pwm_usec_from_dead_stop * 2);
+			ret = pwm_apply_might_sleep(ctx->pwm, state);
+		}
 	} else {
 		ret = pwm_fan_power_off(ctx, false);
 	}
@@ -480,6 +497,7 @@ static int pwm_fan_probe(struct platform_device *pdev)
 	struct device *hwmon;
 	int ret;
 	const struct hwmon_channel_info **channels;
+	u32 pwm_min_from_dead_stop = 0;
 	u32 *fan_channel_config;
 	int channel_count = 1;	/* We always have a PWM channel. */
 	int i;
@@ -620,6 +638,19 @@ static int pwm_fan_probe(struct platform_device *pdev)
 		channels[1] = &ctx->fan_channel;
 	}
 
+	ret = of_property_read_u32(dev->of_node, "fan-dead-stop-start-percent",
+				   &pwm_min_from_dead_stop);
+	if (!ret && pwm_min_from_dead_stop) {
+		ctx->pwm_duty_cycle_from_dead_stop =
+			DIV_ROUND_UP(pwm_min_from_dead_stop *
+				     (ctx->pwm_state.period - 1),
+				     100);
+	}
+	ret = of_property_read_u32(dev->of_node, "fan-dead-stop-start-usec",
+				   &ctx->pwm_usec_from_dead_stop);
+	if (ret)
+		ctx->pwm_usec_from_dead_stop = 250000;
+
 	ctx->info.ops = &pwm_fan_hwmon_ops;
 	ctx->info.info = channels;
 
Signature · 1 line
2.45.2
maintainer
#2 lore raw

Re: [PATCH 2/2] hwmon: (pwm-fan) Introduce start from dead stop handling

Quoted 13 lines · Marek Vasut

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which need to start at higher PWM duty cycle first and can slow down next.

Introduce two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

Quoted 7 lines

Adjust the PWM setting code such that if the PWM duty cycle is below the minimum duty cycle needed by the fan to spin up from dead stop, then first set the PWM duty cycle to the minimum duty cycle needed by the fan to spin up from dead stop, then wait the time necessary for the fan to spin up from dead stop, and finally set the PWM duty cycle to the one desired by user.

As with the other patch, I don't think "dead" adds any value anywhere.

Guenter

Quoted 97 lines

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]

---
  drivers/hwmon/pwm-fan.c | 33 ++++++++++++++++++++++++++++++++-
  1 file changed, 32 insertions(+), 1 deletion(-)
drivers/hwmon/pwm-fan.c +32 -1
index c434db4656e7d..264b7ddf8bb40 100644
@@ -7,6 +7,7 @@
   * Author: Kamil Debski <[email protected]>
   */
 
+#include <linux/delay.h>
  #include <linux/hwmon.h>
  #include <linux/interrupt.h>
  #include <linux/mod_devicetable.h>
@@ -60,6 +61,9 @@ struct pwm_fan_ctx {
 
  	struct hwmon_chip_info info;
  	struct hwmon_channel_info fan_channel;
+
+	u64 pwm_duty_cycle_from_dead_stop;
+	u32 pwm_usec_from_dead_stop;
  };
 
  /* This handler assumes self resetting edge triggered interrupt. */
@@ -199,7 +203,9 @@ static int pwm_fan_power_off(struct pwm_fan_ctx *ctx, bool force_disable)
  static int  __set_pwm(struct pwm_fan_ctx *ctx, unsigned long pwm)
  {
  	struct pwm_state *state = &ctx->pwm_state;
+	unsigned long final_pwm = pwm;
  	unsigned long period;
+	bool update = false;
  	int ret = 0;
 
  	if (pwm > 0) {
@@ -208,11 +214,22 @@ static int  __set_pwm(struct pwm_fan_ctx *ctx, unsigned long pwm)
  			return 0;
 
  		period = state->period;
-		state->duty_cycle = DIV_ROUND_UP(pwm * (period - 1), MAX_PWM);
+		update = state->duty_cycle < ctx->pwm_duty_cycle_from_dead_stop;
+		if (update)
+			state->duty_cycle = ctx->pwm_duty_cycle_from_dead_stop;
+		else
+			state->duty_cycle = DIV_ROUND_UP(pwm * (period - 1), MAX_PWM);
  		ret = pwm_apply_might_sleep(ctx->pwm, state);
  		if (ret)
  			return ret;
  		ret = pwm_fan_power_on(ctx);
+		if (!ret && update) {
+			pwm = final_pwm;
+			state->duty_cycle = DIV_ROUND_UP(pwm * (period - 1), MAX_PWM);
+			usleep_range(ctx->pwm_usec_from_dead_stop,
+				     ctx->pwm_usec_from_dead_stop * 2);
+			ret = pwm_apply_might_sleep(ctx->pwm, state);
+		}
  	} else {
  		ret = pwm_fan_power_off(ctx, false);
  	}
@@ -480,6 +497,7 @@ static int pwm_fan_probe(struct platform_device *pdev)
  	struct device *hwmon;
  	int ret;
  	const struct hwmon_channel_info **channels;
+	u32 pwm_min_from_dead_stop = 0;
  	u32 *fan_channel_config;
  	int channel_count = 1;	/* We always have a PWM channel. */
  	int i;
@@ -620,6 +638,19 @@ static int pwm_fan_probe(struct platform_device *pdev)
  		channels[1] = &ctx->fan_channel;
  	}
 
+	ret = of_property_read_u32(dev->of_node, "fan-dead-stop-start-percent",
+				   &pwm_min_from_dead_stop);
+	if (!ret && pwm_min_from_dead_stop) {
+		ctx->pwm_duty_cycle_from_dead_stop =
+			DIV_ROUND_UP(pwm_min_from_dead_stop *
+				     (ctx->pwm_state.period - 1),
+				     100);
+	}
+	ret = of_property_read_u32(dev->of_node, "fan-dead-stop-start-usec",
+				   &ctx->pwm_usec_from_dead_stop);
+	if (ret)
+		ctx->pwm_usec_from_dead_stop = 250000;
+
  	ctx->info.ops = &pwm_fan_hwmon_ops;
  	ctx->info.info = channels;
 
#3 lore raw

Re: [PATCH 2/2] hwmon: (pwm-fan) Introduce start from dead stop handling

In reply to Marek Vasut
kernel test robot noticed the following build errors:

Hi Marek,

kernel test robot noticed the following build errors:

[auto build test ERROR on groeck-staging/hwmon-next]
[also build test ERROR on linus/master v6.12-rc6 next-20241105] [If your patch is applied to the wrong git tree, kindly drop us a note. And when submitting patch, we suggest to use '--base' as documented in
https://git-scm.com/docs/git-format-patch#_base_tree_information]

url:    https://github.com/intel-lab-lkp/linux/commits/Marek-Vasut/hwmon-pwm-fan-Introduce-start-from-dead-stop-handling/20241105-215454
base:   https://git.kernel.org/pub/scm/linux/kernel/git/groeck/linux-staging.git hwmon-next
patch link:    https://lore.kernel.org/r/20241105135259.101126-2-marex%40denx.de
patch subject: [PATCH 2/2] hwmon: (pwm-fan) Introduce start from dead stop handling
config: arm-defconfig (https://download.01.org/0day-ci/archive/20241106/[email protected]/config)
compiler: clang version 14.0.6 (https://github.com/llvm/llvm-project f28c006a5895fc0e329fe15fead81e37457cb1d1)
reproduce (this is a W=1 build): (https://download.01.org/0day-ci/archive/20241106/[email protected]/reproduce)

If you fix the issue in a separate patch/commit (i.e. not just a new version of the same patch/commit), kindly add following tags
| Reported-by: kernel test robot <[email protected]>
| Closes: https://lore.kernel.org/oe-kbuild-all/[email protected]/

All errors (new ones prefixed by >>, old ones prefixed by <<):

>> ERROR: modpost: "__aeabi_uldivmod" [drivers/hwmon/pwm-fan.ko] undefined!
Signature · 2 lines
0-DAY CI Kernel Test Service
https://github.com/intel/lkp-tests/wiki
#4 lore raw

Re: [PATCH 2/2] hwmon: (pwm-fan) Introduce start from dead stop handling

In reply to Marek Vasut
kernel test robot noticed the following build errors:

Hi Marek,

kernel test robot noticed the following build errors:

[auto build test ERROR on groeck-staging/hwmon-next]
[also build test ERROR on linus/master v6.12-rc6 next-20241106] [If your patch is applied to the wrong git tree, kindly drop us a note. And when submitting patch, we suggest to use '--base' as documented in
https://git-scm.com/docs/git-format-patch#_base_tree_information]

url:    https://github.com/intel-lab-lkp/linux/commits/Marek-Vasut/hwmon-pwm-fan-Introduce-start-from-dead-stop-handling/20241105-215454
base:   https://git.kernel.org/pub/scm/linux/kernel/git/groeck/linux-staging.git hwmon-next
patch link:    https://lore.kernel.org/r/20241105135259.101126-2-marex%40denx.de
patch subject: [PATCH 2/2] hwmon: (pwm-fan) Introduce start from dead stop handling
config: i386-randconfig-016-20241106 (https://download.01.org/0day-ci/archive/20241107/[email protected]/config)
compiler: clang version 19.1.3 (https://github.com/llvm/llvm-project ab51eccf88f5321e7c60591c5546b254b6afab99)
reproduce (this is a W=1 build): (https://download.01.org/0day-ci/archive/20241107/[email protected]/reproduce)

If you fix the issue in a separate patch/commit (i.e. not just a new version of the same patch/commit), kindly add following tags
| Reported-by: kernel test robot <[email protected]>
| Closes: https://lore.kernel.org/oe-kbuild-all/[email protected]/

All errors (new ones prefixed by >>, old ones prefixed by <<):

>> ERROR: modpost: "__udivdi3" [drivers/hwmon/pwm-fan.ko] undefined!
Signature · 2 lines
0-DAY CI Kernel Test Service
https://github.com/intel/lkp-tests/wiki
maintainer
#5 lore raw
In reply to Marek Vasut
Quoted 3 lines · Marek Vasut

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which

Doesn't this imply that a minimum pwm value is needed as well ? Super-IO chips such as the NCT67xx series typically have two separate registers, one for the pwm start value and one for the minimum pwm value.

Quoted 28 lines

need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]

---
  Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 +++++++++++
  1 file changed, 11 insertions(+)
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +0 -0
index 4e5abf7580cc6..f1042471b5176 100644

Documentation/devicetree/bindings/hwmon/pwm-fan.yaml properties: · line 34

Quoted 4 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +1 -0
@@ -31,6 +31,17 @@ properties:
        it must be self resetting edge interrupts.
      maxItems: 1
 
+  fan-dead-stop-start-percent:

Personally I don't think that "dead-stop" in the property name adds any value. On the contrary, I think it leads to confusion. I head to read the description to understand.

Documentation/devicetree/bindings/hwmon/pwm-fan.yaml properties: · line 36

Quoted 2 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +2 -0
+    description:
+      Minimum fan RPM in percent to start from dead stop.

"to start when stopped" should be sufficient.

Documentation/devicetree/bindings/hwmon/pwm-fan.yaml properties: · line 42

Quoted 6 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +6 -0
+    minimum: 0
+    maximum: 100
+
+  fan-dead-stop-start-usec:
+    description:
+      Time to wait in microseconds after start from dead stop.

Same as above for both name and description.

Quoted 5 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +2 -0
+    $ref: /schemas/types.yaml#/definitions/uint32
+
    pulses-per-revolution:
      description:
        Define the number of pulses per fan revolution for each tachometer
#6 lore raw
Quoted 6 lines · Guenter Roeck
Quoted 3 lines · Marek Vasut

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which

Doesn't this imply that a minimum pwm value is needed as well ?

It depends. For this fan, yes, it does stop at around 8% PWM duty cycle.

Quoted 2 lines

Super-IO chips such as the NCT67xx series typically have two separate registers, one for the pwm start value and one for the minimum pwm value.

I use plain SoC PWM output to operate the fan. This one needs to be set to higher PWM duty cycle first, to spin up, and can be reduced to lower PWM duty cycle afterward without stopping.

Quoted 23 lines
Quoted 23 lines

need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]
---
  Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 +++++++++++

  1 file changed, 11 insertions(+)
Quoted 12 lines
Quoted 8 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +0 -0
index 4e5abf7580cc6..f1042471b5176 100644
@@ -31,6 +31,17 @@ properties:

        it must be self resetting edge interrupts.
      maxItems: 1
+  fan-dead-stop-start-percent:

Personally I don't think that "dead-stop" in the property name adds any value. On the contrary, I think it leads to confusion. I head to read the description to understand.

The documentation refers to this behavior as a "dead stop" , hence the property name. I can change it to fan-stop-to-start-percent ?

maintainer
#7 lore raw
Quoted 6 lines · Marek Vasut
Quoted 5 lines · Guenter Roeck
Quoted 3 lines · Marek Vasut

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which

Quoted 9 lines
Quoted 1 line

Doesn't this imply that a minimum pwm value is needed as well ?

It depends. For this fan, yes, it does stop at around 8% PWM duty cycle.

Quoted 2 lines

Super-IO chips such as the NCT67xx series typically have two separate registers, one for the pwm start value and one for the minimum pwm value.

I use plain SoC PWM output to operate the fan. This one needs to be set to higher PWM duty cycle first, to spin up, and can be reduced to lower PWM duty cycle afterward without stopping.

Yes, exactly. That is what many fans require.

Quoted 36 lines
Quoted 23 lines
Quoted 23 lines

need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]
---
  Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 +++++++++++

  1 file changed, 11 insertions(+)
Quoted 12 lines
Quoted 8 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +0 -0
index 4e5abf7580cc6..f1042471b5176 100644
@@ -31,6 +31,17 @@ properties:

        it must be self resetting edge interrupts.
      maxItems: 1
+  fan-dead-stop-start-percent:

Personally I don't think that "dead-stop" in the property name adds any value. On the contrary, I think it leads to confusion. I head to read the description to understand.

Quoted 1 line

The documentation refers to this behavior as a "dead stop" , hence the property name. I can change it to fan-stop-to-start-percent ?

I do not understand the need for that much complexity in the property name, and I don't think it makes sense to name a property based on a specific chip documentation. I have seen that before, where different vendors use different names for the same functionality. That doesn't mean that the vendor-determined name has to make it into the property name.

As an example, Nuvoton calls the values "Start-Up Value" and "Stop Value". ITE calls the start value "start PWM value" (and as far as I can see doesn't have a separate stop value). I am sure pretty much every vendor uses a different description.

I am personally not a friend of long property names. Having said that, I'll let you use whatever DT maintainers accept. They may have a different opinion.

Guenter

#8 lore raw
Quoted 63 lines · Guenter Roeck
Quoted 6 lines · Marek Vasut
Quoted 5 lines · Guenter Roeck
Quoted 3 lines · Marek Vasut

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which

Quoted 9 lines
Quoted 1 line

Doesn't this imply that a minimum pwm value is needed as well ?

It depends. For this fan, yes, it does stop at around 8% PWM duty cycle.

Quoted 2 lines

Super-IO chips such as the NCT67xx series typically have two separate registers, one for the pwm start value and one for the minimum pwm value.

I use plain SoC PWM output to operate the fan. This one needs to be set to higher PWM duty cycle first, to spin up, and can be reduced to lower PWM duty cycle afterward without stopping.

Yes, exactly. That is what many fans require.

Quoted 36 lines
Quoted 23 lines
Quoted 23 lines

need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]
---
  Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 +++++++++++

  1 file changed, 11 insertions(+)
Quoted 12 lines
Quoted 8 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +0 -0
index 4e5abf7580cc6..f1042471b5176 100644
@@ -31,6 +31,17 @@ properties:

        it must be self resetting edge interrupts.
      maxItems: 1
+  fan-dead-stop-start-percent:

Personally I don't think that "dead-stop" in the property name adds any value. On the contrary, I think it leads to confusion. I head to read the description to understand.

Quoted 1 line

The documentation refers to this behavior as a "dead stop" , hence the property name. I can change it to fan-stop-to-start-percent ?

I do not understand the need for that much complexity in the property name, and I don't think it makes sense to name a property based on a specific chip documentation. I have seen that before, where different vendors use different names for the same functionality. That doesn't mean that the vendor-determined name has to make it into the property name.

Quoted 8 lines

As an example, Nuvoton calls the values "Start-Up Value" and "Stop Value". ITE calls the start value "start PWM value" (and as far as I can see doesn't have a separate stop value). I am sure pretty much every vendor uses a different description.

I am personally not a friend of long property names. Having said that, I'll let you use whatever DT maintainers accept. They may have a different opinion.

Do you have a different suggestion for the property name ? Else I'll just send a V2 .

maintainer
#9 lore raw
Quoted 69 lines · Marek Vasut
Quoted 68 lines · Guenter Roeck
Quoted 6 lines · Marek Vasut
Quoted 5 lines · Guenter Roeck
Quoted 3 lines · Marek Vasut

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which

Quoted 9 lines
Quoted 1 line

Doesn't this imply that a minimum pwm value is needed as well ?

It depends. For this fan, yes, it does stop at around 8% PWM duty cycle.

Quoted 2 lines

Super-IO chips such as the NCT67xx series typically have two separate registers, one for the pwm start value and one for the minimum pwm value.

I use plain SoC PWM output to operate the fan. This one needs to be set to higher PWM duty cycle first, to spin up, and can be reduced to lower PWM duty cycle afterward without stopping.

Yes, exactly. That is what many fans require.

Quoted 36 lines
Quoted 23 lines
Quoted 23 lines

need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]
---
  Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 +++++++++++

  1 file changed, 11 insertions(+)
Quoted 12 lines
Quoted 8 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +0 -0
index 4e5abf7580cc6..f1042471b5176 100644
@@ -31,6 +31,17 @@ properties:

        it must be self resetting edge interrupts.
      maxItems: 1
+  fan-dead-stop-start-percent:

Personally I don't think that "dead-stop" in the property name adds any value. On the contrary, I think it leads to confusion. I head to read the description to understand.

Quoted 1 line

The documentation refers to this behavior as a "dead stop" , hence the property name. I can change it to fan-stop-to-start-percent ?

I do not understand the need for that much complexity in the property name, and I don't think it makes sense to name a property based on a specific chip documentation. I have seen that before, where different vendors use different names for the same functionality. That doesn't mean that the vendor-determined name has to make it into the property name.

As an example, Nuvoton calls the values "Start-Up Value" and "Stop Value". ITE calls the start value "start PWM value" (and as far as I can see doesn't have a separate stop value). I am sure pretty much every vendor uses a different description.

Quoted 4 lines
Quoted 3 lines

I am personally not a friend of long property names. Having said that, I'll let you use whatever DT maintainers accept. They may have a different opinion.

Do you have a different suggestion for the property name ? Else I'll just send a V2 .

fan-start-percent and fan-stop-percent would be good enough for me. However, the existing cooling-levels property uses duty cycle values from 0 ..255. Using % for the new properties will create an inconsistency. It will be up to DT maintainers to decide how the properties should be defined.

Guenter

#10 lore raw
Quoted 74 lines · Guenter Roeck
Quoted 73 lines · Marek Vasut
Quoted 72 lines · Guenter Roeck
Quoted 6 lines · Marek Vasut
Quoted 5 lines · Guenter Roeck
Quoted 3 lines · Marek Vasut

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which

Quoted 9 lines
Quoted 1 line

Doesn't this imply that a minimum pwm value is needed as well ?

It depends. For this fan, yes, it does stop at around 8% PWM duty cycle.

Quoted 2 lines

Super-IO chips such as the NCT67xx series typically have two separate registers, one for the pwm start value and one for the minimum pwm value.

I use plain SoC PWM output to operate the fan. This one needs to be set to higher PWM duty cycle first, to spin up, and can be reduced to lower PWM duty cycle afterward without stopping.

Yes, exactly. That is what many fans require.

Quoted 37 lines
Quoted 24 lines
Quoted 24 lines

need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]
---
  Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 ++++++
+++++

  1 file changed, 11 insertions(+)
Quoted 12 lines
Quoted 8 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +0 -0
index 4e5abf7580cc6..f1042471b5176 100644
@@ -31,6 +31,17 @@ properties:

        it must be self resetting edge interrupts.
      maxItems: 1
+  fan-dead-stop-start-percent:

Personally I don't think that "dead-stop" in the property name adds any value. On the contrary, I think it leads to confusion. I head to read the description to understand.

Quoted 1 line

The documentation refers to this behavior as a "dead stop" , hence the property name. I can change it to fan-stop-to-start-percent ?

I do not understand the need for that much complexity in the property name, and I don't think it makes sense to name a property based on a specific chip documentation. I have seen that before, where different vendors use different names for the same functionality. That doesn't mean that the vendor-determined name has to make it into the property name.

As an example, Nuvoton calls the values "Start-Up Value" and "Stop Value". ITE calls the start value "start PWM value" (and as far as I can see doesn't have a separate stop value). I am sure pretty much every vendor uses a different description.

I am personally not a friend of long property names. Having said that, I'll let you use whatever DT maintainers accept. They may have a different opinion.

Quoted 8 lines
Quoted 1 line

Do you have a different suggestion for the property name ? Else I'll just send a V2 .

fan-start-percent and fan-stop-percent would be good enough for me. However, the existing cooling-levels property uses duty cycle values from 0 ..255. Using % for the new properties will create an inconsistency. It will be up to DT maintainers to decide how the properties should be defined.

All right, well ... I sent V2 with what I have in tree now, and let's see what happens.

#11 lore raw
In reply to Marek Vasut
Quoted 31 lines · Marek Vasut

Delta AFC0612DB-F00 fan has to be set to at least 30% PWM duty cycle to spin up from a dead stop, and can be afterward throttled down to lower PWM duty cycle. Introduce support for operating such fans which need to start at higher PWM duty cycle first and can slow down next.

Document two new DT properties, "fan-dead-stop-start-percent" and "fan-dead-stop-start-usec". The former describes the minimum percent of fan RPM at which it will surely spin up from dead stop. This value can be found in the fan datasheet and can be converted to PWM duty cycle easily. The "fan-dead-stop-start-usec" describes the minimum time in microseconds for which the fan has to be set to dead stop start RPM for the fan to surely spin up.

---
Cc: Conor Dooley <[email protected]>
Cc: Guenter Roeck <[email protected]>
Cc: Jean Delvare <[email protected]>
Cc: Krzysztof Kozlowski <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: [email protected]
Cc: [email protected]

---
 Documentation/devicetree/bindings/hwmon/pwm-fan.yaml | 11 +++++++++++
 1 file changed, 11 insertions(+)
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +0 -0
index 4e5abf7580cc6..f1042471b5176 100644

Documentation/devicetree/bindings/hwmon/pwm-fan.yaml properties: · line 40

Quoted 10 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +7 -0
@@ -31,6 +31,17 @@ properties:
       it must be self resetting edge interrupts.
     maxItems: 1
 
+  fan-dead-stop-start-percent:
+    description:
+      Minimum fan RPM in percent to start from dead stop.
+    minimum: 0
+    maximum: 100
+
+  fan-dead-stop-start-usec:

s/usec/us/ and you get the type from property-units.yaml automagically.

Quoted 10 lines
Documentation/devicetree/bindings/hwmon/pwm-fan.yaml +4 -0
+    description:
+      Time to wait in microseconds after start from dead stop.
+    $ref: /schemas/types.yaml#/definitions/uint32
+
   pulses-per-revolution:
     description:
       Define the number of pulses per fan revolution for each tachometer
Signature · 1 line
2.45.2