Skip to contentSkip to conversation

hwmon: vt1211 documentation update

PATCH New Juerg Haefliger 2 participants 4 messages Sep 2, 2006 – Sep 3, 2006

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 hwmon: vt1211 documentation update

This patch adds a description of the module load parameters to the documentation of the vt1211.

Signed-off-by Juerg Haefliger <juergh at gmail.com>

---

hwmon/vt1211 2006-09-02 14:56:02.000000000 -0700 renamed from hwmon/vt1211.orig 2006-09-02 14:38:59.000000000 -0700 +11 -0
@@ -16,6 +16,26 @@
 technical support.
 
 
+Module Parameters
+-----------------
+
+* uch_config: int      Override the BIOS default universal channel (UCH)
+                       configuration for channels 1-5.
+                       Legal values are in the range of 0-31. Bit 0 maps to
+                       UCH1, bit 1 maps to UCH2 and so on. Setting a bit to 1
+                       enables the thermal input of that particular UCH and
+                       setting a bit to 0 enables the voltage input.
+
+* int_mode: int                Override the BIOS default temperature

interrupt mode.

+                       The only possible value is 0 which forces interrupt
+                       mode 0. In this mode, any pending interrupt is cleared
+                       when the status register is read but is regenerated as
+                       long as the temperature stays above the hysteresis
+                       limit.

+
+Be aware that overriding BIOS defaults might cause some unwanted side effects! +
+
Description
-----------

@@ -88,9 +108,7 @@
hysteresis value with each temperature below which the temperature has to drop before the alarm is cleared (this is only true for interrupt mode 0). The interrupt mode can be forced to 0 in case the BIOS doesn't do it
-automatically. For that, the parameter int_mode=0 needs to be supplied when -loading the driver module. Be aware that overriding BIOS defaults might cause -some unwanted side effects!
+automatically. See the 'Module Parameters' section for details.

All temperature channels except temp2 are external. Temp2 is the VT1211 internal thermal diode and the driver does all the scaling for temp2 and

#1 lore raw

PATCH 1/1 hwmon: vt1211 documentation update

Hi Juerg,

Quoted 4 lines

This patch adds a description of the module load parameters to the documentation of the vt1211.

Signed-off-by Juerg Haefliger <juergh at gmail.com>

Eek, it appears that your mailer broke the patch by wrapping long lines. Please send it again. If your mailer can't deal with inline patches, just attach it instead, that's fine with me.

Thanks,

Quoted 44 lines

---

hwmon/vt1211 2006-09-02 14:56:02.000000000 -0700 renamed from hwmon/vt1211.orig 2006-09-02 14:38:59.000000000 -0700 +11 -0
@@ -16,6 +16,26 @@
 technical support.
 
 
+Module Parameters
+-----------------
+
+* uch_config: int      Override the BIOS default universal channel (UCH)
+                       configuration for channels 1-5.
+                       Legal values are in the range of 0-31. Bit 0 maps to
+                       UCH1, bit 1 maps to UCH2 and so on. Setting a bit to 1
+                       enables the thermal input of that particular UCH and
+                       setting a bit to 0 enables the voltage input.
+
+* int_mode: int                Override the BIOS default temperature

interrupt mode.

hwmon/vt1211 2006-09-02 14:56:02.000000000 -0700 renamed from hwmon/vt1211.orig 2006-09-02 14:38:59.000000000 -0700 +10 -3
+                       The only possible value is 0 which forces interrupt
+                       mode 0. In this mode, any pending interrupt is cleared
+                       when the status register is read but is regenerated as
+                       long as the temperature stays above the hysteresis
+                       limit.
+
+Be aware that overriding BIOS defaults might cause some unwanted side effects!
+
+
 Description
 -----------
@@ -88,9 +108,7 @@
 hysteresis value with each temperature below which the temperature has to drop
 before the alarm is cleared (this is only true for interrupt mode 0). The
 interrupt mode can be forced to 0 in case the BIOS doesn't do it
-automatically. For that, the parameter int_mode=0 needs to be supplied when
-loading the driver module. Be aware that overriding BIOS defaults might cause
-some unwanted side effects!
+automatically. See the 'Module Parameters' section for details.
 
 All temperature channels except temp2 are external. Temp2 is the VT1211
 internal thermal diode and the driver does all the scaling for temp2 and
Signature · 1 line
Jean Delvare
#2 lore raw

PATCH 1/1 hwmon: vt1211 documentation update

In reply to Juerg Haefliger

This patch adds a description of the module load parameters to the documentation of the vt1211.

Signed-off-by: Juerg Haefliger <juergh at gmail.com>
-------------- next part --------------
A non-text attachment was scrubbed...
Name: hwmon-vt1211-add-module-parameters-description.patch
Type: text/x-patch
Size: 1617 bytes
Desc: not available
Url : http://lists.lm-sensors.org/pipermail/lm-sensors/attachments/20060903/17f52def/attachment.bin

Applied
#3 lore raw

PATCH 1/1 hwmon: vt1211 documentation update

In reply to Juerg Haefliger
Quoted 4 lines

This patch adds a description of the module load parameters to the documentation of the vt1211.

Signed-off-by Juerg Haefliger <juergh at gmail.com>

Applied.

hwmon/vt1211

Quoted 2 lines
hwmon/vt1211 renamed from hwmon/vt1211.orig +0 -0

Next time, please make sure to send a p1-style patch.

Signature · 1 line
Jean Delvare