How to set serial console on 712 (fwd)
|How do I set the console on my 712 to be the serial port, not the graphics |display? | |Thanks |
Boot to ISL and use the conspath
command to change the console back to rs232. The command to use is:
serial
conspath 2/0/4.643
graphics
conspath 1/0/0.0Quoted 6 lines · Bill Katz William
|How do I set the console on my 712 to be the serial port, not the graphics |display? | |Thanks |
Quoted 7 lines
Boot to ISL and use the conspath
command to change the console back to rs232. The command to use is:serial
conspath 2/0/4.643 graphics conspath 1/0/0.0
This contradicts the PA-RISC Booting HOWTO:
-----
3.1.2.3.3. How can I change the boot console to serial on a 712?
Unfortunately, you can't. Although 712s are configured for in-house HP development to use serial console, this configuration isn't supported in the field. You have to use a graphics console for 712s.
-----
I'd like to know if this needs to be corrected.
Matthew Wilcox writes...
Quoted 2 lines · Bill Katz William
Quoted 1 line
|How do I set the console on my 712 to be the serial port, not the
graphics
Quoted 19 lines
Quoted 5 lines
|display? | |Thanks |Quoted 7 lines
Boot to ISL and use the conspath
command to change the console back to rs232. The command to use is:serial
conspath 2/0/4.643 graphics conspath 1/0/0.0This contradicts the PA-RISC Booting HOWTO:
-----
3.1.2.3.3. How can I change the boot console to serial on a 712?
Quoted 7 lines
Unfortunately, you can't. Although 712s are configured for in-house HP development to use serial console, this configuration isn't supported in the field. You have to use a graphics console for 712s.
-----
I'd like to know if this needs to be corrected.
The above statement about serial console not being "supported" on 712 is correct. That doesn't mean you can't do it. Here are the instructions,
-------------
CONFIGURING A RS-232 CONSOLE on a 712
An RS-232 console is not a supported feature in the 712 products. For this reason users cannot select the RS-232 port as a console from the BOOT_ADMIN prompt.
These instructions will configure an RS-232 console with 9600 Baud, 8 data bits, 1 stop bit, and no parity.
HOW-TO INSTRUCTIONS
NOTE: If the following instructions are not entered correctly, your system may be left in an un-usable state. Contact support to "dagger" your system in this case.
Power up the 712 system.
Press (ESCAPE) during boot to abort auto booting the system. At the BOOT_ADMIN> prompt, use the boot command and the isl keyword.
This will stop the boot sequence at ISL instead of booting to the
OS.
For example: 'boot scsi.6 isl'
At the ISL> prompt, type 'conspath 2/0/4.0x283'
At the ISL> prompt, type 'disp' and verify console path is:
(hex) 2/0/4.283.0.0.0.0.0
If necessary re-type the conspath command above.
Connect an RS-232 terminal to the system.
Power cycle the system to bring it up on an RS-232 console.
-------------
As it indicates above, *BE VERY CAREFUL* or you can hose your system. If you
do, I have one of the "dagger" cards that can be loaned out to fix it.
Signature · 2 lines
Matt Taggart [email protected]
Is there a way to use a serial console with a 715 however?
Quoted 82 lines · Matt Taggart
Matthew Wilcox writes...
Quoted 2 lines · Bill Katz William
Quoted 1 line
|How do I set the console on my 712 to be the serial port, not the
graphics
Quoted 19 lines
Quoted 5 lines
|display? | |Thanks |Quoted 7 lines
Boot to ISL and use the conspath
command to change the console back to rs232. The command to use is:serial
conspath 2/0/4.643 graphics conspath 1/0/0.0This contradicts the PA-RISC Booting HOWTO:
-----
3.1.2.3.3. How can I change the boot console to serial on a 712?
Quoted 7 lines
Unfortunately, you can't. Although 712s are configured for in-house HP development to use serial console, this configuration isn't supported in the field. You have to use a graphics console for 712s.
-----
I'd like to know if this needs to be corrected.
The above statement about serial console not being "supported" on 712 is correct. That doesn't mean you can't do it. Here are the instructions,
-------------
CONFIGURING A RS-232 CONSOLE on a 712An RS-232 console is not a supported feature in the 712 products. For this reason users cannot select the RS-232 port as a console from the
BOOT_ADMINprompt.These instructions will configure an RS-232 console with 9600 Baud, 8 data bits, 1 stop bit, and no parity.
HOW-TO INSTRUCTIONS
NOTE: If the following instructions are not entered correctly, your system may be left in an un-usable state. Contact support to "dagger" your system in this case.
Power up the 712 system.
Press (ESCAPE) during boot to abort auto booting the system. At theBOOT_ADMIN> prompt, use the boot command and the isl keyword.
This will stop the boot sequence at ISL instead of booting to the
OS.
For example: 'boot scsi.6 isl'
At the ISL> prompt, type 'conspath 2/0/4.0x283'
At the ISL> prompt, type 'disp' and verify console path is:
(hex) 2/0/4.283.0.0.0.0.0
If necessary re-type the conspath command above.
Connect an RS-232 terminal to the system.
Power cycle the system to bring it up on an RS-232 console.
-------------As it indicates above, *BE VERY CAREFUL* or you can hose your system. If you
do, I have one of the "dagger" cards that can be loaned out to fix it.Signature · 9 lines
Matt Taggart [email protected] --------------------------------------------------------------------------- To unsubscribe: send e-mail to [email protected] with `unsubscribe' as the subject.
MaShaun Jones writes...
Quoted 1 line
Is there a way to use a serial console with a 715 however?
As someone mentioned previously, just unplug the keyboard. Almost all HP-PA workstations will go to serial if they can't find a keyboard. The only one I know of that doesn't is the 712. If you want to force an HP-PA workstation to serial(even if a keyboard is plugged in) then set the console path in the firmware. It varies by machine but it's usually pretty easy. The "help" command should give you an example for the machine you're on. The 712 was purposely obfuscated so people wouldn't use serial console.
Signature · 2 lines
Matt Taggart [email protected]
Quoted 1 line · MaShaun Jones
Is there a way to use a serial console with a 715 however?
Yes, and it features in the HOWTO:
i've used a 715 in this configuration myself.
Quoted 1 line · MaShaun Jones
Is there a way to use a serial console with a 715 however?
Another method:
PDC will use serial port 1 as console if one holds TOC button (near the power button) for about 10 seconds while powering on.
grant
Grant Grundler
Unix Developement Lab
+1.408.447.7253