Testing the adeos-ipipe-2.6.13-ppc-1.0-00.patch
Wolfgang Grandegger wrote:
[...]
Quoted 6 lines
Quoted 2 lines
Load for klatency/latency was ping flooding on FCC (piece of cake), and cache calibrator. IMHO, we can do nastier.
You mean the cache calibrator from http://monetdb.cwi.nl/Calibrator/? I tried it on my Ocotea board and it increased the max latency for 25 to 30 us.
Yes, that very one. In this case, it has been used as a cache trashing load generator. But IMHO, this Calibrator should be better used in the Benchmarking Plan to get L1/L2/RAM access latency figures (w/o RT running),
and offer one more correlation against RT latency results.
We can afford a better cache trashing load generator. Earlier this year, I proposed flushy(tm) [1], but as Philippe suggested, we can do better. Flushy should be rewritten as an ADEOS layer, inserted just in front of Xenomai in the pipeline. This way, we would be sure the caches are dead cold when Xenomai enter its domain. Using tools like OProfile, it should be possible then to track cache misses, and fix them by prefetching, where available.
[1] http://rtai.dk/cgi-bin/gratiswiki.pl?Latency_Killer (bottom of page)
Here is the result of my 1.0-01 tests on e500:
$ cat /proc/ipipe/version 1.0-01
SWITCH without load:
RTH| lat min| lat avg| lat max| lost RTD| 3660| 3690| 8070| 0 1.0-00 RTD| 4620| 4740| 8730| 0 1.0-01
KLATENCY with load:
RTH|-----lat min|-----lat avg|-----lat max|-overrun| RTS| -7350| -5715| 6420| 0| 00:03:17 1.0-00 RTS| -6150| -4384| 12180| 0| 00:03:13 1.0-01
LATENCY with load:
== Sampling period: 100 us
RTH|-----lat min|-----lat avg|-----lat max|-overrun| RTS| -6930| -4260| 8700| 0| 00:08:06 1.0-00 RTS| -5670| -4620| 12930| 0| 00:12:39 1.0-01
That's weird. Figures are worse, but since the load (ping -f + calibrator)
was executed manually, it may not be the same.
Signature · 1 line
Stephane
Quoted 43 lines · Fillod Stephane
Wolfgang Grandegger wrote:
[...]Quoted 6 lines
Quoted 2 lines
Load for klatency/latency was ping flooding on FCC (piece of cake), and cache calibrator. IMHO, we can do nastier.
You mean the cache calibrator from http://monetdb.cwi.nl/Calibrator/? I tried it on my Ocotea board and it increased the max latency for 25 to 30 us.
Yes, that very one. In this case, it has been used as a cache trashing load generator. But IMHO, this Calibrator should be better used in the Benchmarking Plan to get L1/L2/RAM access latency figures (w/o RT running),
and offer one more correlation against RT latency results.We can afford a better cache trashing load generator. Earlier this year,
I proposed flushy(tm) [1], but as Philippe suggested, we can do better.
Flushy should be rewritten as an ADEOS layer, inserted just in front of Xenomai in the pipeline. This way, we would be sure the caches are dead cold when Xenomai enter its domain. Using tools like OProfile,
it should be possible then to track cache misses, and fix them by prefetching, where available.[1] http://rtai.dk/cgi-bin/gratiswiki.pl?Latency_Killer (bottom of page)
Here is the result of my 1.0-01 tests on e500:
$ cat /proc/ipipe/version 1.0-01SWITCH without load:
RTH| lat min| lat avg| lat max| lost RTD| 3660| 3690| 8070| 0 1.0-00 RTD| 4620| 4740| 8730| 0 1.0-01KLATENCY with load:
RTH|-----lat min|-----lat avg|-----lat max|-overrun| RTS| -7350| -5715| 6420| 0| 00:03:17 1.0-00 RTS| -6150| -4384| 12180| 0| 00:03:13 1.0-01LATENCY with load:
== Sampling period: 100 us
Quoted 8 lines
RTH|-----lat min|-----lat avg|-----lat max|-overrun| RTS| -6930| -4260| 8700| 0| 00:08:06 1.0-00 RTS| -5670| -4620| 12930| 0| 00:12:39 1.0-01That's weird. Figures are worse, but since the load (ping -f + calibrator)
was executed manually, it may not be the same.
Ok, I now suspect that another change regarding the size of the interrupt counters made this worse. I'm going to revert it and upload -02, just to make sure.
Signature · 1 line
Philippe.
Quoted 51 lines · Philippe Gerum
Quoted 49 lines · Fillod Stephane
Wolfgang Grandegger wrote:
[...]Quoted 7 lines
Quoted 2 lines
Load for klatency/latency was ping flooding on FCC (piece of cake), and cache calibrator. IMHO, we can do nastier.
You mean the cache calibrator from http://monetdb.cwi.nl/Calibrator/? I tried it on my Ocotea board and it increased the max latency for 25 to 30 us.
Yes, that very one. In this case, it has been used as a cache trashing load generator. But IMHO, this Calibrator should be better used in the Benchmarking Plan to get L1/L2/RAM access latency figures (w/o RT running),
and offer one more correlation against RT latency results.We can afford a better cache trashing load generator. Earlier this year,
I proposed flushy(tm) [1], but as Philippe suggested, we can do better.
Flushy should be rewritten as an ADEOS layer, inserted just in front of Xenomai in the pipeline. This way, we would be sure the caches are dead cold when Xenomai enter its domain. Using tools like OProfile,
it should be possible then to track cache misses, and fix them by prefetching, where available.[1] http://rtai.dk/cgi-bin/gratiswiki.pl?Latency_Killer (bottom of page)
Here is the result of my 1.0-01 tests on e500:
$ cat /proc/ipipe/version 1.0-01SWITCH without load:
RTH| lat min| lat avg| lat max| lost RTD| 3660| 3690| 8070| 0 1.0-00 RTD| 4620| 4740| 8730| 0 1.0-01KLATENCY with load:
RTH|-----lat min|-----lat avg|-----lat max|-overrun| RTS| -7350| -5715| 6420| 0| 00:03:17 1.0-00 RTS| -6150| -4384| 12180| 0| 00:03:13 1.0-01LATENCY with load:
== Sampling period: 100 usRTH|-----lat min|-----lat avg|-----lat max|-overrun| RTS| -6930| -4260| 8700| 0| 00:08:06 1.0-00 RTS| -5670| -4620| 12930| 0| 00:12:39 1.0-01
Quoted 8 lines
Quoted 4 lines
That's weird. Figures are worse, but since the load (ping -f + calibrator)
was executed manually, it may not be the same.Ok, I now suspect that another change regarding the size of the interrupt counters made this worse. I'm going to revert it and upload -02, just to make sure.
http://download.gna.org/adeos/patches/v2.6/adeos/ppc/adeos-ipipe-2.6.13-ppc-1.0-02.patch
Signature · 1 line