3COM 3c905c-TX-M.... works, or not?
Hello, I've been fighting with various 10/100 NIC's for three days now, including a LinkSys NC100 & LNE100TX, Netgear FA311, and now, a 3com 3c905c-TX-M. The Netgear didn't work *at all*; the LinkSys cards worked, but were incredibly flaky; and now it appears the 3com *somewhat* works (ie, TX light flashes when I ping another machine on the network), but I can't actually ping any other machines on the network. A 'cat /proc/interrupts' shows that there have been no interrupts serviced for the card:
CPU0
1: 0 PMAC-PIC eth1 2: 0 PMAC-PIC MACE-txdma 3: 0 PMAC-PIC MACE-rxdma 4: 0 PMAC-PIC SCC-txdma 5: 4412 PMAC-PIC SCC-rxdma 6: 0 PMAC-PIC SCC-txdma 7: 0 PMAC-PIC SCC-rxdma 8: 0 PMAC-PIC AWACS out 12: 34 PMAC-PIC 53C94 13: 223409 PMAC-PIC MESH 14: 0 PMAC-PIC MACE 15: 133432 PMAC-PIC SCC 16: 0 PMAC-PIC SCC 17: 0 PMAC-PIC AWACS 18: 140 PMAC-PIC VIA 19: 0 PMAC-PIC SWIM3 20: 0 PMAC-PIC NMI - XMON 24: 9202 PMAC-PIC usb-ohci
BAD: 0
At bootup I get the following:
3c59x.c 16Aug00 Donald Becker and others http://www.scyld.com/network/vortex.html
The PCI BIOS has not enabled the device at 1/0. Updating PCI command 0014->0015.
eth1: 3Com 3c905C Tornado at 0x1000, 00:01:02:c1:88:c2, IRQ 1
8K byte-wide RAM 5:3 Rx:Tx split, autoselect/Autonegotiate interface. MII transceiver found at address 24, status 786d.
Enabling bus-master transmits and whole-frame receives.
And sometime after attempting to ping another machine, I get:
eth1: transmit timed out, tx_status 00 status e601.
eth1: Interrupt posted but not delivered -- IRQ blocked by another device?
Flags; bus-master 1, full 0; dirty 16 current 16.
Transmit list 00000000 vs. c0521a00.
0: @c0521a00 length 8000002a status 0001002a 1: @c0521a10 length 8000002a status 0001002a 2: @c0521a20 length 8000002a status 0001002a 3: @c0521a30 length 8000002a status 0001002a 4: @c0521a40 length 8000002a status 0001002a 5: @c0521a50 length 8000002a status 0001002a 6: @c0521a60 length 8000002a status 0001002a 7: @c0521a70 length 8000002a status 0001002a 8: @c0521a80 length 8000002a status 0001002a 9: @c0521a90 length 8000002a status 0001002a 10: @c0521aa0 length 8000002a status 0001002a 11: @c0521ab0 length 8000002a status 0001002a 12: @c0521ac0 length 8000002a status 0001002a 13: @c0521ad0 length 8000002a status 0001002a 14: @c0521ae0 length 8000002a status 8001002a 15: @c0521af0 length 8000002a status 8001002a
eth1: Resetting the Tx ring pointer.
Has anyone successfully gotten the 3C905-TX-M to work on a PowerPC box? Just FYI, the box in question is a UMAX S900 w/ Sonnet G3/350, and the NIC is located in PCI slot 4.
I'm sure someone here has attempted to install a second ethernet card in their PowerPC box, so if no one knows how to get this card to work, can anyone recommend a card that *does* work? This is driving me nuts...
Thanks in advance,
Jonathan
** Sent via the linuxppc-dev mail list. See http://lists.linuxppc.org/
Hi there,
On 2 Dec, this message from Jonathan Lane echoed through cyberspace:
Quoted 5 lines
A 'cat
/proc/interrupts' shows that there have
been no interrupts serviced for the card:CPU0
1: 0 PMAC-PIC eth1
Hmmm, IRQ 1? Weird for a PCI device....
Quoted 2 lines
20: 0 PMAC-PIC NMI - XMON 24: 9202 PMAC-PIC usb-ohci
I suppose your USB is on a PCI card in a PCI slot? I'd expect the other PCI slot's interrupts to be next to this one, then.
Quoted 1 line
eth1: 3Com 3c905C Tornado at
0x1000, 00:01:02:c1:88:c2, IRQ 1
Everything OK, except IRQ1...
Quoted 2 lines
eth1: transmit timed out,
tx_status00 status e601.
eth1: Interrupt posted but not delivered -- IRQ blocked by another device?
Yes, IRQ problem.... Could you send a complete lspci -vv along, together with lspci -bvv (bus view)?
Michel
-------------------------------------------------------------------------
Michel Lanners | " Read Philosophy. Study Art. 23, Rue Paul Henkes | Ask Questions. Make Mistakes. L-1710 Luxembourg | email [email protected] | http://www.cpu.lu/~mlan | Learn Always. "
** Sent via the linuxppc-dev mail list. See http://lists.linuxppc.org/