Problems Compiling 2_4 for 860
Hello:
I have been compiling using the MVISTA tools the kernel 2_4 from bitkeeper.
The CPU is = XPC860TZP50B5
I have follow the following Steps.
- make mrproper
- make rpxcllf_config
- make oldconfig
- make dep zImage
Finally I may compile the zImage, but when I try to load from the Board, doesnt Recognize the file, the message is :
load_tftp(): ** E_RPX_NOT_SREC
What should be error ??
Regards
Arturo Nunez
** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/
Arturo,
You did not convert the output from make zImage to an s-records file. This can be done through objcopy. Then you load the s-records file and you should not get the error you see.
Cal Erickson
Quoted 10 lines · Arturo Nunez
Hello:
I have been compiling using the MVISTA tools the kernel 2_4 from bitkeeper.
The CPU is = XPC860TZP50B5
I have follow the following Steps.
- make mrproper
- makerpxcllf_config
- make oldconfig
- make dep zImage
Quoted 9 lines
Finally I may compile the zImage, but when I try to load from the Board, doesnt Recognize the file, the message is :
load_tftp(): **E_RPX_NOT_SREC
What should be error ??
RegardsArturo Nunez
--
===========================================================================
Cal Erickson MontaVista Software Inc. Linux Consultant 1237 E. Arques Ave. Phone (408) 328-0304 Sunnyvale CA 94085 Fax (408) 328-9204 web http://www.mvista.com
eCode: http://[email protected]
===========================================================================
** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/
Hello:
Quoted 4 lines
Arturo,
You did not convert the output from make zImage to an s-records file. This can be done through objcopy. Then you load the s-records file and you should not get the error you see.
Thanks.
Also I have used "zsrec",as:
$zsrec arch/ppc/mbxboot/zImage > vmlinuz.srec
BUT what I cant manage is the 100mbits port.
Even its recognized through the Kernel as eth1, I cant manage it. I have defined 2 Ip adresses, each one for the 10 and the 100 Mbits ports All its OK.
But when I disconnect the cable from the FEC port is the other port that answers the Pings ???
Thats Wierd.
Suggestions Welcome...
Regards
Arturo Nunez
** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/