two minor c3k bugs
A message that is not in the archive (sent off-list or not yet received): [email protected]
Quoted 2 lines · Helge Deller
Forwarded to the list, since it may be of interest for others too:
sure.
Quoted 1 line · Grant Grundler
...
Quoted 2 lines
Hmm, I still have 2.4.16-pa4 here and it definately shows "2.4.16-pa4" for me. Maybe a SMP problem ?
No. I only build UP kernels for the C3k.
Quoted 2 lines
You could try to double the size of the
udelay()parameter inlcd_printto see if it cures your problem.
After a reboot it worked fine. Could be a timing problem. Since I can't reproduce it reliably and it's minor, I'm not going to chase this. Someday when I get bored and ate too much chocolate (dark, organic, Belgian from Trader Joe's), I might try to run IRC on the LCD... ;^)
...
Quoted 2 lines
Currently I use "
kill_proc(1, SIGINT, 0);" to kill the init-process - which is normally a reboot-command and gives the above messages.
Ok. that makes sense.
Quoted 2 lines
That's AFAICS not the right solution, but nfortunately I don't know how to do it correct right now.
./kernel/sys.c: printk(KERN_EMERG "Power down.\n");
That chunk of code seems to do the right thing:
case LINUX_REBOOT_CMD_POWER_OFF:
notifier_call_chain(&reboot_notifier_list, SYS_POWER_OFF, NULL);
printk(KERN_EMERG "Power down.\n");
machine_power_off();
do_exit(0);
break; I know that msg since I regularly "powerdown" my c3k. Perhaps replicate that code?
cheers,
grant
Hi Grant,
Quoted 13 lines · Grant Grundler
Quoted 2 lines
Currently I use "
kill_proc(1, SIGINT, 0);" to kill the init-process - which is normally a reboot-command and gives the above messages.Ok. that makes sense.
Quoted 2 lines
That's AFAICS not the right solution, but nfortunately I don't know how to do it correct right now.
./kernel/sys.c:printk(KERN_EMERG "Power down.\n");That chunk of code seems to do the right thing:
caseLINUX_REBOOT_CMD_POWER_OFF:
notifier_call_chain(&reboot_notifier_list,SYS_POWER_OFF,
Quoted 7 lines
NULL); printk(KERN_EMERG "Power down.\n"); machine_power_off(); do_exit(0); break;I know that msg since I regularly "powerdown" my c3k. Perhaps replicate that code?
Yes, that's the right code-path, but sadly calling this function would immediately power off the computer without doing a nice system shutdown.
I'll need to investigate how to first find the PID of the init process and then how to tell it to shut down the system cleanly.
Helge
Quoted 2 lines
cheers,
grant