replacing faulty hd
Hi,
we have a raid5 with persistent superblock and need to replace one of the harddisks.
Currently 3 of 4 md-devices (each built from 5 partition of 5 disks) work fine and have full raid5 support, but for md0 only 4 partitions are active.
What happens if we shutdown the server and replace the faulty disk by a new unpartitioned one ? I'm a bit worried that due to the autostart due to the persistent superblock something could become destroyed.
Actually I would prever an kernel parameter to disable raid autostart and first partition the harddisk, but so far I havn't found something like this.
Thanks,
Bernd
Quoted 11 lines · On Friday October 25, [email protected] wrote:
Hi,
we have a raid5 with persistent superblock and need to replace one of the harddisks.
Currently 3 of 4 md-devices (each built from 5 partition of 5 disks) work fine and have full raid5 support, but for md0 only 4 partitions are active.
What happens if we shutdown the server and replace the faulty disk by a new unpartitioned one ? I'm a bit worried that due to the autostart due to the persistent superblock something could become destroyed.
It should work fine.
Quoted 4 lines
Actually I would prever an kernel parameter to disable raid autostart and first partition the harddisk, but so far I havn't found something like this.
raid=noautodetect
NeilBrown
Hi,
thanks all (Martin and Michael sent their mails directly to my) for answering my questions, we could replace the hd without any problems.
Quoted 3 lines
raid=noautodetect
This I was looking for, thanks !
Bernd