Catching NForce2 lockup with NMI watchdog
Quoted 3 lines
Having had cause to try and figure out all this, I vote for the following being included in the source somewhere...
-g
Please consider adding
2c. Alternatively the OUT0 output of the 8254 PIT (IOW the timer source) may be directly connected to the INTIN0 input of the first I/O APIC.
which we have found for nforce2 boards.
ref:
http://linux.derkeiler.com/Mailing-Lists/Kernel/2003-12/2375.html
Ross Dickson
Quoted 36 lines
Quoted 35 lines · bill davidsen
In article <[email protected]>, Maciej W. Rozycki <[email protected]> wrote:
| The I/O APIC NMI watchdog utilizes the property of being transparent to a | single IRQ source of a specially reconfigured 8259A PIC (the master one in | the IA32 PC architecture). There are more prerequisites that have to be | met and all indeed are for a 100% compatible PC as specified by the | Intel's Multiprocessor Specification. | | 1. The INT output of the master 8259A PIC has to be connected to the LINT0 | (or LINTIN0; the name varies by implementations) inputs of all local APICs | in the system. | | 2a. The OUT0 output of the 8254 PIT (IOW the timer source) has to be | directly connected to the INTIN2 input of the first I/O APIC. | | 2b. Alternatively the INT output of the master 8259A PIC has to be | connected to the INTIN0 input of the first I/O APIC. | | 3. There must be no glue logic that would change logical properties of the | signal between the INT output of the master 8259A PIC and the respective | APIC interrupt inputs. | | In practice, assuming the MP IRQ routing information provided the BIOS has | been correct (which is not always the case), prerequisites #1 and #2 have | been met so far, but #3 has proved to be occasionally problematic.In practice many system seem to take a good bit of guessing and testing. I have an old P-II which only works with acpi=force and nmi_watchdog=2, for instance.
It would be nice if there were a program which could poke at the hardware and suggest options which might work, as in eliminating the ones which can be determined not to work. Absent that trial and error rule, unfortunately.
Quoted 6 lines · Ross Dickson
Please consider adding
2c. Alternatively the OUT0 output of the 8254 PIT (IOW the timer source) may be directly connected to the INTIN0 input of the first I/O APIC.
which we have found for nforce2 boards.
Actually the code can handle routing to any INTIN pins, so the whole text
needs to be reworded. It's just that I've got used to INTIN0 and INTIN2 after that many years. ;-)
Signature · 3 lines
+ Maciej W. Rozycki, Technical University of Gdansk, Poland + +--------------------------------------------------------------+ + e-mail: [email protected], PGP key available +