Skip to contentSkip to conversation

Always call blkdev_put when destroying a vbd in device backend

PATCH In review Michael Vrable 3 participants 3 messages Aug 27, 2004 – Aug 28, 2004

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 Always call blkdev_put when destroying a vbd in device backend

The code for the block backend device in XenoLinux 2.6.8.1 doesn't call blkdev_put on all code paths that can destroy a vbd. Previously, blkdev_put was only called from vbd_shrink. I've added the call to vbd_destroy and destroy_all_vbds.

With the old code, the kernel running in domain-0 would believe the devices exported to another domain to still be in use, even after the other domain was shutdown. (This was obvious when using LVM, since the logical volumes were still listed as open, and a warning message was printed when shutting down LVM.) This patch should fix that.

--Michael Vrable

linux-2.6.8.1-xen-sparse/drivers/xen/blkback/vbd.c +6 -0
diff -urN orig/linux-2.6.8.1-xen-sparse/drivers/xen/blkback/vbd.c mod/linux-2.6.8.1-xen-sparse/drivers/xen/blkback/vbd.c
@@ -305,6 +305,9 @@
     while ( x != NULL )
     {
         t = x->next;
+#if LINUX_VERSION_CODE >= KERNEL_VERSION(2,6,0)
+        blkdev_put(x->bdev);
+#endif
         kfree(x);
         x = t;
     }
@@ -330,6 +333,9 @@
         while ( x != NULL )
         {
             t = x->next;
+#if LINUX_VERSION_CODE >= KERNEL_VERSION(2,6,0)
+            blkdev_put(x->bdev);
+#endif
             kfree(x);
             x = t;
         }          
#1 lore raw
Quoted 10 lines · Michael Vrable

The code for the block backend device in XenoLinux 2.6.8.1 doesn't call blkdev_put on all code paths that can destroy a vbd. Previously, blkdev_put was only called from vbd_shrink. I've added the call to vbd_destroy and destroy_all_vbds.

With the old code, the kernel running in domain-0 would believe the devices exported to another domain to still be in use, even after the other domain was shutdown. (This was obvious when using LVM, since the logical volumes were still listed as open, and a warning message was printed when shutting down LVM.) This patch should fix that.

Thanks. I've applied the patch.

christian

-------------------------------------------------------
This SF.Net email is sponsored by BEA Weblogic Workshop FREE Java Enterprise J2EE developer tools!
Get your free copy of BEA WebLogic Workshop 8.1 today.
http://ads.osdn.com/?ad_id=5047&alloc_id=10808&op=click

#2 lore raw
Quoted 6 lines · Christian Limpach
Quoted 5 lines · Michael Vrable

The code for the block backend device in XenoLinux 2.6.8.1 doesn't call blkdev_put on all code paths that can destroy a vbd. Previously, blkdev_put was only called from vbd_shrink. I've added the call to vbd_destroy and destroy_all_vbds.

Quoted 7 lines
Quoted 5 lines

With the old code, the kernel running in domain-0 would believe the devices exported to another domain to still be in use, even after the other domain was shutdown. (This was obvious when using LVM, since the logical volumes were still listed as open, and a warning message was printed when shutting down LVM.) This patch should fix that.

Thanks. I've applied the patch.

That patch is a bit ugly. Version checks scattered thruout the code is not something Linus likes.

Better to make a macro that expands to nothing when not needed, and place it in a header file.

-------------------------------------------------------
This SF.Net email is sponsored by BEA Weblogic Workshop FREE Java Enterprise J2EE developer tools!
Get your free copy of BEA WebLogic Workshop 8.1 today.
http://ads.osdn.com/?ad_id=5047&alloc_id=10808&op=click