Hello,

I'm doing fail over testing with a Qlogic 2344 (only using ports 1 and 2). I've successfully failed over from 1 port to 2, then failed back to port 1, however, when I pull both cables, then plug in port 2 or 1, fail over will not take affect. I am required to plug in both cables in order to get the devices back online.

I got the following messages from the qla2xxx driver when I plugged a single cable back in after pulling both:

Dec  6 23:05:26 fe-nntp-07 kernel: qla2x00: no more failovers for

request - pid= 2210820

This message would scroll continuously.

Any comments or ideas? Is this a bug or a feature?

Thanks,
Ben

#1 lore raw
Quoted 7 lines
Dec  6 23:05:26 fe-nntp-07 kernel: qla2x00: no more failovers for

request - pid= 2210820

This message would scroll continuously.

Any comments or ideas? Is this a bug or a feature?

There's not such printk in the kernel qla2xxx driver, so the bugs is in front of the computer as you patched in a bogus vendor driver.

author
#2 lore raw
Quoted 3 lines

There's not such printk in the kernel qla2xxx driver, so the bugs is in front of the computer as you patched in a bogus vendor driver.

I apologize, the version of the qla2xxx driver was obtained from qlogic's ftp site. I assumed it was the beta versions being developed at the qla2xxx sourceforge site as their ftp was referenced for updated version (which I understand is the ones that get worked into the kernel?). I will contact qlogic directly.

Thanks,
Ben