3Ware 9500S-12 RAID controller -- poor performance
Dear list,
After almost two weeks of experimentation, google searches and reading of posts, bug reports and discussions I'm still far from an answer. I'm hoping someone on this list could shed some light on the subject.
I'm using a 3Ware 9500S-12 card and am able to produce up to 400MB/s sustained read from my 12-disk 4.1TB RAID5 SATA array, 128MB cache onboard, ext3 formatted.
All is well when performing a single read -- it
works nice and fast.
The system is a web server, serving mid-size files (50MB, each, on average). All hell breaks loose when doing many concurrent reads, anywhere between 200 to 400 concurrent streams things simply grind to a halt and the system transfers a maximum of 12-14MB/s.
I'm in the process of clearing up the array (this would take some time) and restructuring it to JBOD mode in order to use each disk individually. I will use a filesystem more suitable to streaming large files, such as XFS. But this would take time and I would very much appreciate the advice of people in the
know if this is going to help at all. It's hard for
me to make extreme experimentation (deleting, formatting, reformatting) as this is a productio n system with many files that I have no other place to dump until they can be safely removed. Though I'm working on dumping them slowly to other, remote, machines.
I'm running the latest kernel, 2.6.13.2 and the latest 3Ware driver, taken from the 3ware.com web site which upon insmod, updates the card's firmware to the latest version as well.
In my experiments, I've tried using larger readahead, currently at 16k (this helps, higher values do not seem to help much), using the deadline scheduler for this device, booting the system with the 'noapic' option and playing with a bunch of VM tunable parameters which I'm not sure that I should really be touching. At the moment only the readahead modification is used as the other stuff simply didn't help at all.
With the stock kernel shipped with my distribution, 2.6.8 and its old 3ware driver things were just as
worse but manifested themselves differently. The
system was visibly (top, vmstat...) spending most of its time in io-wait and load average was extremely
high, in the area of 10 to 20. With the recent
kernel and driver mentioned above, the excessive io-wait and load seems to have been resolved and observed loadavg is between 1 and 4.
I don't have much experience with systems that are supposed to stream many files concurrently off a hardware RAID of this configuration, but my gut feeling is that something is very wrong and I should be seeing a much higher read throughput.
Trying to preempt people's questions I've tried to include as much information as possible, a lot of stuff is pasted below.
I've just seen that the 3ware driver shares the same IRQ with my ethernet card, which has got me a little worried, should I be?
System uptime, exactly 1 day:
# cat /proc/interrupts
CPU0 CPU1
0: 21619638 0 XT-PIC timer
2: 0 0 XT-PIC cascade
8: 4 0 XT-PIC rtc
10: 268753224 0 XT-PIC 3w-9xxx,
eth0
14: 11 0 XT-PIC ide0
15: 337881 0 XT-PIC libata
NMI: 0 0
LOC: 21110402 21557685
ERR: 0
MIS: 0# free
total used free shared
buffers cached
Mem: 2075260 2024724 50536 0
5184 1388408
-/+ buffers/cache: 631132 1444128
Swap: 3903784 0 3903784# vmstat -n 1 (output of the last few seconds): procs -----------memory---------- ---swap-- -----io---- --system-- ----cpu---- 0 0 0 49932 4760 1392980 0 0 15636 32 3169 3697 4 6 30 60 0 0 0 50816 4752 1392376 0 0 5844 0 3114 3929 3 5 91 1 0 0 0 50924 4772 1391404 0 0 9360 0 3187 4348 6 6 76 13 0 2 0 50552 4780 1391532 0 0 24976 44 4077 3906 3 7 65 25 0 1 0 50444 4780 1392688 0 0 20192 0 5048 3914 7 8 56 30 0 1 0 50568 4756 1392508 0 0 21248 0 4060 3603 4 6 48 41 0 0 0 50704 4724 1392268 0 0 30004 0 3834 3369 4 9 65 22 0 3 0 50556 4728 1392468 0 0 3248 1832 2974 4514 2 5 58 35 0 3 0 50308 4724 1392200 0 0 1288 336 1766 1886 1 3 50 47 0 4 0 50308 4732 1391852 0 0 2300 408 1919 2158 0 3 51 46 0 4 0 50556 4736 1390692 0 0 1856 532 1488 1846 3 1 50 46 0 3 0 50680 4740 1390620 0 0 4016 1296 1577 1682 2 2 50 47 0 3 0 50432 4752 1391628 0 0 2180 72 1730 1945 2 2 51 46 2 2 0 49924 4772 1391540 0 0 44372 564 3403 2847 4 5 50 42 0 0 0 50684 4784 1391528 0 0 28640 216 3804 3847 7 8 69 16
# cat /proc/cpuinfo processor : 0 vendor_id : GenuineIntel cpu family : 15 model : 4 model name : Intel(R) Xeon(TM) CPU 3.00GHz stepping : 1 cpu MHz : 2993.035 cache size : 1024 KB physical id : 0 siblings : 2 core id : 0 cpu cores : 1 fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 5 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm pni monitor ds_c pl cid cx16 xtpr bogomips : 5993.68
processor : 1vendor_id : GenuineIntel
cpu family : 15
model : 4
model name : Intel(R) Xeon(TM) CPU 3.00GHz
stepping : 1
cpu MHz : 2993.035
cache size : 1024 KB
physical id : 3
siblings : 2
core id : 3
cpu cores : 1fdiv_bug : nohlt_bug : nof00f_bug : nocoma_bug : no
fpu : yesfpu_exception : yes
cpuid level : 5
wp : yes
flags : fpu vme de pse tsc msr pae mce cx8
apic sep mtrr pge mca cmov
pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm pni monitor ds_c
pl cid cx16 xtpr
bogomips : 5985.52
# lspci 0000:00:00.0 Host bridge: Intel Corporation E7520 Memory Controller Hub (rev 0c) 0000:00:00.1 ff00: Intel Corporation E7525/E7520 Error Reporting Registers (rev 0c) 0000:00:01.0 System peripheral: Intel Corporation E7520 DMA Controller (rev 0c) 0000:00:02.0 PCI bridge: Intel Corporation E7525/E7520/E7320 PCI Express Port A (rev 0c) 0000:00:04.0 PCI bridge: Intel Corporation E7525/E7520 PCI Express Port B (rev 0 c) 0000:00:05.0 PCI bridge: Intel Corporation E7520 PCI Express Port B1 (rev 0c) 0000:00:06.0 PCI bridge: Intel Corporation E7520 PCI Express Port C (rev 0c) 0000:00:1d.0 USB Controller: Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #1 (rev 02) 0000:00:1d.1 USB Controller: Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #2 (rev 02) 0000:00:1d.2 USB Controller: Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #3 (rev 02) 0000:00:1d.7 USB Controller: Intel Corporation 82801EB/ER (ICH5/ICH5R) USB2 EHCI Controller (rev 02) 0000:00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev c2) 0000:00:1f.0 ISA bridge: Intel Corporation 82801EB/ER (ICH5/ICH5R) LPC Interface Bridge (rev 02) 0000:00:1f.1 IDE interface: Intel Corporation 82801EB/ER (ICH5/ICH5R) IDE Contro ller (rev 02) 0000:00:1f.2 IDE interface: Intel Corporation 82801EB (ICH5) SATA Controller (re v 02) 0000:00:1f.3 SMBus: Intel Corporation 82801EB/ER (ICH5/ICH5R) SMBus Controller ( rev 02) 0000:01:00.0 PCI bridge: Intel Corporation 6700PXH PCI Express-to-PCI Bridge A ( rev 09) 0000:01:00.1 PIC: Intel Corporation 6700/6702PXH I/OxAPIC Interrupt Controller A (rev 09) 0000:01:00.2 PCI bridge: Intel Corporation 6700PXH PCI Express-to-PCI Bridge B ( rev 09) 0000:01:00.3 PIC: Intel Corporation 6700PXH I/OxAPIC Interrupt Controller B (rev 09) 0000:03:01.0 RAID bus controller: 3ware Inc 9xxx-series SATA-RAID 0000:05:00.0 Ethernet controller: Marvell Technology Group Ltd. 88E8050 Gigabit Ethernet Controller (rev 18) 0000:07:04.0 Ethernet controller: Intel Corporation 82541GI/PI Gigabit Ethernet Controller (rev 05) 0000:07:0c.0 VGA compatible controller: ATI Technologies Inc Rage XL (rev 27)
As you can see, this is a fairly recent motherboard that's supposed to perform well, though I don't know the manufacturer of this board as the machine is hosted and I don't have physical access, though I can ask them if anyone would like to know.
The ethernet card actually being used is the Intel E1000 with NAPI support compiled.
If there's any bit of information that's missing, please let me know and I'd he happy to provide it quickly.
If you can suggest a better (non Netapp, EMC, etc) solution that is somehow affordable and can provide the very high read throughputs please let me know, I'm very interested in solutions that can staturate multiple gigabit links (of course, using more than one machine ;)
Please CC me on any replies as I'm not subscribed to the list.
Thank you for listening!
__________________________________
Yahoo! Mail - PC Magazine Editors' Choice 2005
http://mail.yahoo.com
Why are you booting with 'noapic'.. in my experience that will seriously impact interrupt performance. Use the APIC if you've got it, which in this case you definitely do.
Yes, having your gigabit NIC and RAID controller on the same IRQ (in PIC mode) could definitely me a source of trouble.
In your web server testing, were you using an external traffic generator or an on-host process? If you try on-host (eliminating the network throughput and related interrupts) does performance improve?
So two biggest suggestions:
- Use the APIC. It is your friend.
- It looks like the 3ware card and gigabit nic are on different busses, but the pirq lines are being routed to the same legacy interrupt in PIC mode. So APIC mode should avoid that problem. If the controller and nic are actually on the same bus, separate them.
Regards,
Ian Morgan
Signature · 5 lines
-------------------------------------------------------------------
Ian E. Morgan Vice President & C.O.O. Webcon, Inc.
imorgan at webcon dot ca PGP: #2DA40D07 www.webcon.ca
* Customized Linux network solutions for your business *
-------------------------------------------------------------------Quoted 277 lines · subbie subbie
Dear list,
After almost two weeks of experimentation, google searches and reading of posts, bug reports and discussions I'm still far from an answer. I'm hoping someone on this list could shed some light on the subject.
I'm using a 3Ware 9500S-12 card and am able to produce up to 400MB/s sustained read from my 12-disk 4.1TB RAID5 SATA array, 128MB cache onboard, ext3 formatted.
All is well when performing a single read -- it
works nice and fast.The system is a web server, serving mid-size files (50MB, each, on average). All hell breaks loose when doing many concurrent reads, anywhere between 200 to 400 concurrent streams things simply grind to a halt and the system transfers a maximum of 12-14MB/s.
I'm in the process of clearing up the array (this would take some time) and restructuring it to JBOD mode in order to use each disk individually. I will use a filesystem more suitable to streaming large files, such as XFS. But this would take time and I would very much appreciate the advice of people in the
know if this is going to help at all. It's hard for
me to make extreme experimentation (deleting, formatting, reformatting) as this is a productio n system with many files that I have no other place to dump until they can be safely removed. Though I'm working on dumping them slowly to other, remote, machines.I'm running the latest kernel, 2.6.13.2 and the latest 3Ware driver, taken from the 3ware.com web site which upon insmod, updates the card's firmware to the latest version as well.
In my experiments, I've tried using larger readahead, currently at 16k (this helps, higher values do not seem to help much), using the deadline scheduler for this device, booting the system with the 'noapic' option and playing with a bunch of VM tunable parameters which I'm not sure that I should really be touching. At the moment only the readahead modification is used as the other stuff simply didn't help at all.
With the stock kernel shipped with my distribution, 2.6.8 and its old 3ware driver things were just as
worse but manifested themselves differently. The
system was visibly (top, vmstat...) spending most of its time in io-wait and load average was extremely
high, in the area of 10 to 20. With the recent
kernel and driver mentioned above, the excessive io-wait and load seems to have been resolved and observed loadavg is between 1 and 4.I don't have much experience with systems that are supposed to stream many files concurrently off a hardware RAID of this configuration, but my gut feeling is that something is very wrong and I should be seeing a much higher read throughput.
Trying to preempt people's questions I've tried to include as much information as possible, a lot of stuff is pasted below.
I've just seen that the 3ware driver shares the same IRQ with my ethernet card, which has got me a little worried, should I be?
System uptime, exactly 1 day:
# cat /proc/interrupts CPU0 CPU1 0: 21619638 0 XT-PIC timer 2: 0 0 XT-PIC cascade 8: 4 0 XT-PIC rtc 10: 268753224 0 XT-PIC 3w-9xxx, eth0 14: 11 0 XT-PIC ide0 15: 337881 0 XT-PIC libata NMI: 0 0 LOC: 21110402 21557685 ERR: 0 MIS: 0# free total used free shared buffers cached Mem: 2075260 2024724 50536 0 5184 1388408 -/+ buffers/cache: 631132 1444128 Swap: 3903784 0 3903784# vmstat -n 1 (output of the last few seconds): procs -----------memory---------- ---swap-- -----io---- --system-- ----cpu---- 0 0 0 49932 4760 1392980 0 0 15636 32 3169 3697 4 6 30 60 0 0 0 50816 4752 1392376 0 0 5844 0 3114 3929 3 5 91 1 0 0 0 50924 4772 1391404 0 0 9360 0 3187 4348 6 6 76 13 0 2 0 50552 4780 1391532 0 0 24976 44 4077 3906 3 7 65 25 0 1 0 50444 4780 1392688 0 0 20192 0 5048 3914 7 8 56 30 0 1 0 50568 4756 1392508 0 0 21248 0 4060 3603 4 6 48 41 0 0 0 50704 4724 1392268 0 0 30004 0 3834 3369 4 9 65 22 0 3 0 50556 4728 1392468 0 0 3248 1832 2974 4514 2 5 58 35 0 3 0 50308 4724 1392200 0 0 1288 336 1766 1886 1 3 50 47 0 4 0 50308 4732 1391852 0 0 2300 408 1919 2158 0 3 51 46 0 4 0 50556 4736 1390692 0 0 1856 532 1488 1846 3 1 50 46 0 3 0 50680 4740 1390620 0 0 4016 1296 1577 1682 2 2 50 47 0 3 0 50432 4752 1391628 0 0 2180 72 1730 1945 2 2 51 46 2 2 0 49924 4772 1391540 0 0 44372 564 3403 2847 4 5 50 42 0 0 0 50684 4784 1391528 0 0 28640 216 3804 3847 7 8 69 16# cat /proc/cpuinfo processor : 0 vendor_id : GenuineIntel cpu family : 15 model : 4 model name : Intel(R) Xeon(TM) CPU 3.00GHz stepping : 1 cpu MHz : 2993.035 cache size : 1024 KB physical id : 0 siblings : 2 core id : 0 cpu cores : 1 fdiv_bug : no hlt_bug : no f00f_bug : no coma_bug : no fpu : yes fpu_exception : yes cpuid level : 5 wp : yes flags : fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm pni monitor ds_c pl cid cx16 xtpr bogomips : 5993.68processor : 1
vendor_id: GenuineIntel
cpu family : 15
model : 4
model name : Intel(R) Xeon(TM) CPU 3.00GHz
stepping : 1
cpu MHz : 2993.035
cache size : 1024 KB
physical id : 3
siblings : 2
core id : 3
cpu cores : 1fdiv_bug: nohlt_bug: nof00f_bug: nocoma_bug: no
fpu : yesfpu_exception: yes
cpuid level : 5
wp : yes
flags : fpu vme de pse tsc msr pae mce cx8
apic sep mtrr pge mca cmov
pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe nx lm pni monitords_c
pl cid cx16 xtpr
bogomips : 5985.52# lspci 0000:00:00.0 Host bridge: Intel Corporation E7520 Memory Controller Hub (rev 0c) 0000:00:00.1 ff00: Intel Corporation E7525/E7520 Error Reporting Registers (rev 0c) 0000:00:01.0 System peripheral: Intel Corporation E7520 DMA Controller (rev 0c) 0000:00:02.0 PCI bridge: Intel Corporation E7525/E7520/E7320 PCI Express Port A (rev 0c) 0000:00:04.0 PCI bridge: Intel Corporation E7525/E7520 PCI Express Port B (rev 0 c) 0000:00:05.0 PCI bridge: Intel Corporation E7520 PCI Express Port B1 (rev 0c) 0000:00:06.0 PCI bridge: Intel Corporation E7520 PCI Express Port C (rev 0c) 0000:00:1d.0 USB Controller: Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #1 (rev 02) 0000:00:1d.1 USB Controller: Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #2 (rev 02) 0000:00:1d.2 USB Controller: Intel Corporation 82801EB/ER (ICH5/ICH5R) USB UHCI Controller #3 (rev 02) 0000:00:1d.7 USB Controller: Intel Corporation 82801EB/ER (ICH5/ICH5R) USB2 EHCI Controller (rev 02) 0000:00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev c2) 0000:00:1f.0 ISA bridge: Intel Corporation 82801EB/ER (ICH5/ICH5R) LPC Interface Bridge (rev 02) 0000:00:1f.1 IDE interface: Intel Corporation 82801EB/ER (ICH5/ICH5R) IDE Contro ller (rev 02) 0000:00:1f.2 IDE interface: Intel Corporation 82801EB (ICH5) SATA Controller (re v 02) 0000:00:1f.3 SMBus: Intel Corporation 82801EB/ER (ICH5/ICH5R) SMBus Controller ( rev 02) 0000:01:00.0 PCI bridge: Intel Corporation 6700PXH PCI Express-to-PCI Bridge A ( rev 09) 0000:01:00.1 PIC: Intel Corporation 6700/6702PXH I/OxAPIC Interrupt Controller A (rev 09) 0000:01:00.2 PCI bridge: Intel Corporation 6700PXH PCI Express-to-PCI Bridge B ( rev 09) 0000:01:00.3 PIC: Intel Corporation 6700PXH I/OxAPIC Interrupt Controller B (rev 09) 0000:03:01.0 RAID bus controller: 3ware Inc 9xxx-series SATA-RAID 0000:05:00.0 Ethernet controller: Marvell Technology Group Ltd. 88E8050 Gigabit Ethernet Controller (rev 18) 0000:07:04.0 Ethernet controller: Intel Corporation 82541GI/PI Gigabit Ethernet Controller (rev 05) 0000:07:0c.0 VGA compatible controller: ATI Technologies Inc Rage XL (rev 27)As you can see, this is a fairly recent motherboard that's supposed to perform well, though I don't know the manufacturer of this board as the machine is hosted and I don't have physical access, though I can ask them if anyone would like to know.
The ethernet card actually being used is the Intel E1000 with NAPI support compiled.
If there's any bit of information that's missing, please let me know and I'd he happy to provide it quickly.
If you can suggest a better (non Netapp, EMC, etc) solution that is somehow affordable and can provide the very high read throughputs please let me know, I'm very interested in solutions that can staturate multiple gigabit links (of course, using more than one machine ;)
Please CC me on any replies as I'm not subscribed to the list.
Thank you for listening!
Dear Ian,
'noapic' was a recommendation by 3Ware / AMCC tech
support. It did not help at all, as expected.
Unfortunately they did not have any other recommendations.
I've now removed 'noapic' and unfortunately nothing
has changed, really. See current stats below.
# cat /proc/interrupts
CPU0 CPU1
0: 64713875 355 IO-APIC-edge timer
2: 0 0 XT-PIC cascade
8: 3 1 IO-APIC-edge rtc
14: 7 6 IO-APIC-edge ide0
16: 176847225 191855106 IO-APIC-level eth0
18: 499139 336893 IO-APIC-level libata
48: 31491551 22761438 IO-APIC-level 3w-9xxx
NMI: 0 0
LOC: 64049632 64155206
ERR: 0
MIS: 0# uptime 08:39:14 up 2 days, 23:54, 8 users, load average: 0.16, 0.13, 0.07
I have also tried playing with the parameters our friend Ville has mentioned in his post, nothing has come out of it.
I'm willing to give any developer here access to my production machine so that they can see the situation
first hand. Performance is just aweful.
I'm planning to ditch RAID5 on this card and try JBOD and in spreading files evenly across my 12 disks, hopefully this would give some benifit.
Something is very wrong with this card / driver / firmware and or kernel combination, hopefully someone can help out.
Much appreciated
Quoted 29 lines · --- Ian Morgan
Why are you booting with 'noapic'.. in my experience that will seriously
impact interrupt performance. Use the APIC if you've got it, which in this
case you definitely do.Yes, having your gigabit NIC and RAID controller on the same IRQ (in PIC
mode) could definitely me a source of trouble.In your web server testing, were you using an external traffic generator or
an on-host process? If you try on-host (eliminating the network throughput
and related interrupts) does performance improve?So two biggest suggestions:
- Use the APIC. It is your friend.
- It looks like the 3ware card and gigabit nic are on different busses, but
the pirq lines are being routed to the same legacy interrupt in PIC mode. So
APIC mode should avoid that problem. If the controller and nic are actually
on the same bus, separate them.
Quoted 5 lines
Regards,
Ian Morgan
-------------------------------------------------------------------
Quoted 7 lines
Ian E. Morgan Vice President & C.O.O.
Webcon, Inc.
imorgan at webcon dot ca PGP: #2DA40D07
www.webcon.ca
* Customized Linux network solutions for your
business *
-------------------------------------------------------------------
Quoted 118 lines · subbie subbie
Quoted 6 lines
Dear list,
After almost two weeks of experimentation, google searches and reading of posts, bug reports and discussions I'm still far from an answer. I'm
hoping
Quoted 4 lines
someone on this list could shed some light on the subject.
I'm using a 3Ware 9500S-12 card and am able to
produce
Quoted 2 lines
up to 400MB/s sustained read from my 12-disk 4.1TB RAID5 SATA array, 128MB cache onboard, ext3
formatted.
Quoted 5 lines
All is well when performing a single read -- it
works nice and fast.The system is a web server, serving mid-size files (50MB, each, on average). All hell breaks loose
when
Quoted 1 line
doing many concurrent reads, anywhere between 200
to
Quoted 1 line
400 concurrent streams things simply grind to a
halt
Quoted 5 lines
and the system transfers a maximum of 12-14MB/s.
I'm in the process of clearing up the array (this would take some time) and restructuring it to JBOD mode in order to use each disk individually. I
will
Quoted 2 lines
use a filesystem more suitable to streaming large files, such as XFS. But this would take time and
I
Quoted 1 line
would very much appreciate the advice of people in
the
Quoted 1 line
know if this is going to help at all. It's hard
for
Quoted 3 lines
me to make extreme experimentation (deleting, formatting, reformatting) as this is a productio n system with many files that I have no other place
to
Quoted 5 lines
dump until they can be safely removed. Though I'm working on dumping them slowly to other, remote, machines.
I'm running the latest kernel, 2.6.13.2 and the
latest
Quoted 1 line
3Ware driver, taken from the 3ware.com web site
which
Quoted 1 line
upon insmod, updates the card's firmware to the
latest
Quoted 3 lines
version as well.
In my experiments, I've tried using larger
readahead,
Quoted 2 lines
currently at 16k (this helps, higher values do not seem to help much), using the deadline scheduler
for
Quoted 3 lines
this device, booting the system with the 'noapic' option and playing with a bunch of VM tunable parameters which I'm not sure that I should really
be
Quoted 2 lines
touching. At the moment only the readahead modification is used as the other stuff simply
didn't
Quoted 3 lines
help at all.
With the stock kernel shipped with my
distribution,
Quoted 2 lines
2.6.8 and its old 3ware driver things were just as worse but manifested themselves differently.
The
Quoted 1 line
system was visibly (top, vmstat...) spending most
of
Quoted 10 lines
its time in io-wait and load average was extremely
high, in the area of 10 to 20. With the recent
kernel and driver mentioned above, the excessive io-wait and load seems to have been resolved and observed loadavg is between 1 and 4.I don't have much experience with systems that are supposed to stream many files concurrently off a hardware RAID of this configuration, but my gut feeling is that something is very wrong and I
should
Quoted 7 lines
be seeing a much higher read throughput.
Trying to preempt people's questions I've tried to include as much information as possible, a lot of stuff is pasted below.
I've just seen that the 3ware driver shares the
same
Quoted 1 line
IRQ with my ethernet card, which has got me a
little
Quoted 10 lines
worried, should I be?
System uptime, exactly 1 day:
# cat /proc/interrupts CPU0 CPU1 0: 21619638 0 XT-PIC timer 2: 0 0 XT-PIC cascade 8: 4 0 XT-PIC rtc 10: 268753224 0 XT-PIC3w-9xxx,
Quoted 8 lines
eth0
14: 11 0 XT-PIC ide0 15: 337881 0 XT-PIC libata NMI: 0 0 LOC: 21110402 21557685 ERR: 0 MIS: 0
Quoted 43 lines
Quoted 4 lines
# free total used free shared buffers cached Mem: 2075260 2024724 505360
Quoted 37 lines
5184 1388408
-/+ buffers/cache: 631132 1444128
Swap: 3903784 0 3903784# vmstat -n 1 (output of the last few seconds): procs -----------memory---------- ---swap-- -----io---- --system-- ----cpu---- 0 0 0 49932 4760 1392980 0 0 15636 32 3169 3697 4 6 30 60 0 0 0 50816 4752 1392376 0 0 5844 0 3114 3929 3 5 91 1 0 0 0 50924 4772 1391404 0 0 9360 0 3187 4348 6 6 76 13 0 2 0 50552 4780 1391532 0 0 24976 44 4077 3906 3 7 65 25 0 1 0 50444 4780 1392688 0 0 20192 0 5048 3914 7 8 56 30 0 1 0 50568 4756 1392508 0 0 21248 0 4060 3603 4 6 48 41 0 0 0 50704 4724 1392268 0 0 30004 0 3834 3369 4 9 65 22 0 3 0 50556 4728 1392468 0 0 3248 1832 2974 4514 2 5 58 35 0 3 0 50308 4724 1392200 0 0 1288 336 1766 1886 1 3 50 47 0 4 0 50308 4732 1391852 0 0 2300 408 1919 2158 0 3 51 46 0 4 0 50556 4736 1390692 0 0 1856 532 1488 1846 3 1 50 46 0 3 0 50680 4740 1390620 0 0 4016 1296 1577 1682 2 2 50 47 0 3 0 50432 4752 1391628 0 0 2180 72 1730 1945 2 2 51 46 2 2 0 49924 4772 1391540 0 0 44372 564 3403 2847 4 5 50 42 0 0 0 50684 4784 1391528 0 0 28640 216 3804 3847 7 8 69 16
=== message truncated ===
__________________________________
Yahoo! Mail - PC Magazine Editors' Choice 2005
http://mail.yahoo.com
Quoted 3 lines
Something is very wrong with this card / driver / firmware and or kernel combination, hopefully someone can help out.
I think I have to agree; see my post from:
http://marc.theaimsgroup.com/?l=linux-kernel&m=112282837926689&w=2
I've got about 30MB/s from a single threaded version of my backup code - which seems rather on the low side for a modern RAID-5; with multiple writers I was seeing sub-5MB/s but that might be fair if it is seeking everywhere.
I'd be interested to hear how your experiments with jbod'ing them go.
Dave
--
-----Open up your eyes, open up your mind, open up your code -------
/ Dr. David Alan Gilbert | Running GNU/Linux on Alpha,68K| Happy \ \ gro.gilbert @ treblig.org | MIPS,x86,ARM,SPARC,PPC & HPPA | In Hex / \ _________________________|_____ http://www.treblig.org |_______/
A single thread writing at 30MB/s is still not on par with 3ware's specs.
I see that you're also running RAID5 and in this case 3ware did report bad write performance on RAID5 and that was fixed with recent firmwares.
The latest linux driver off their website also includes the latest firmware inside it and flashes the card upon load, make sure to use that.
I'm getting a little over 50MB/s when writing to my RAID volume when completely idle, there's no reason why you should get less.
As for read performance, nothing helps with many concurrent reads, what I get is simply aweful performance no matter what I do.
I'll let you guys know once I try JBOD (as soon as all the data is moved away).
According to Ville answering me privately:
Quoted 1 line
Unfortunately, it's not limited to just that
firmware version or kernel version or driver version. I've tried several firmwares, 2.4.x and 2.6.x kernels and driver version - no salvage.
I do agree, which leads me to believe this is something very specific with the RAID controller itself or its firmware.
Maybe something is so badly designed in this controller that it can't physically do better than that ? Anyone has experience with this controller and its performance on windoze?
Can someone in the know give us some input ?
Thanks
Quoted 8 lines · --- "Dr. David Alan Gilbert
Quoted 2 lines
Something is very wrong with this card / driver /
firmware and or kernel combination, hopefullysomeone
Quoted 1 line
can help out.
I think I have to agree; see my post from:
http://marc.theaimsgroup.com/?l=linux-kernel&m=112282837926689&w=2
Quoted 12 lines
I've got about 30MB/s from a single threaded version of my
backup code - which seems rather on the low side for a modern RAID-5; with multiple writers I was seeing sub-5MB/s
but that might be fair if it is seeking everywhere.I'd be interested to hear how your experiments with jbod'ing them
go.
Quoted 11 lines
Dave
--
-----Open up your eyes, open up your mind, open up
your code -------
/ Dr. David Alan Gilbert | Running GNU/Linux on
Alpha,68K| Happy \
\ gro.gilbert @ treblig.org | MIPS,x86,ARM,SPARC,PPC & HPPA | In Hex /
\ _________________________|_____
http://www.treblig.org |_______/
__________________________________
Yahoo! Mail - PC Magazine Editors' Choice 2005
http://mail.yahoo.com
Quoted 10 lines · * subbie subbie ([email protected]) wrote:
A single thread writing at 30MB/s is still not on par with 3ware's specs.
I see that you're also running RAID5 and in this case 3ware did report bad write performance on RAID5 and that was fixed with recent firmwares.
The latest linux driver off their website also includes the latest firmware inside it and flashes the card upon load, make sure to use that.
I've got driver/firmware that is about 2months old that certainly helped; prior to that I was getting card timeouts (although I also upgraded the e1000 driver at the same time so it might have been that rather than the 3ware that helped).
(Note: I don't expect a driver to perform a dangerous operation like firmware flashing on boot!)
Quoted 3 lines
I'm getting a little over 50MB/s when writing to my RAID volume when completely idle, there's no reason why you should get less.
Well my ~30MB/s is sucking over gig ether and writing in 10MB chunks; but still 50MB/s for RAID5 feels like it sucks.
Quoted 2 lines
I'll let you guys know once I try JBOD (as soon as all the data is moved away).
Nod.
Dave
--
-----Open up your eyes, open up your mind, open up your code -------
/ Dr. David Alan Gilbert | Running GNU/Linux on Alpha,68K| Happy \ \ gro.gilbert @ treblig.org | MIPS,x86,ARM,SPARC,PPC & HPPA | In Hex / \ _________________________|_____ http://www.treblig.org |_______/
Hi
Quoted 7 lines
I've got driver/firmware that is about 2months old that
certainly helped; prior to that I was getting card timeouts (although I also upgraded the e1000 driver at the same time so it might have been that rather than the 3ware that helped).
Two months old might be too old, make sure you have at least 9.2.1.1
Quoted 3 lines
(Note: I don't expect a driver to perform a dangerous
operation like firmware flashing on boot!)
I believe they are writing to NVRAM or similar so that makes it much less risky, otherwise they wouldn't have to write it on each load ... or I might be wrong and they do it once, not sure.
Quoted 11 lines
Quoted 1 line
I'm getting a little over 50MB/s when writing to
my
Quoted 1 line
RAID volume when completely idle, there's no
reason
Quoted 1 line
why you should get less.
Well my ~30MB/s is sucking over gig ether and writing
in 10MB chunks; but still 50MB/s for RAID5 feels like
it sucks.
Yes, that's terrible.
Reading the release notes for the latest one, 9.3.0 that also supports their very latest controller, 9550SX, I get the feeling that write performance is something of an on-going issue with this family of controllers even though they disguise it in this latest driver version as a tweak in write performance.
Another thing, the BBU (battery backup unit) that you are using was also a can of worms for them so this makes it even more important for you to upgrade to the very latest version ,they seem to be having ongoing issues with that one.
Good luck to us all.
__________________________________
Yahoo! Mail - PC Magazine Editors' Choice 2005
http://mail.yahoo.com
I have seen some systems on which IRQ load balancing can have a detrimental effect on some devices such as gigabit Ethernet etc.
You could try disabling both the irqbalance userspace daemon (if that's part of your distribution), and in-kernel IRQ balancing, if enabled (CONFIG_IRQBALANCE).
For your NIC, try enabling NAPI interrupt mitigation, if available. This will significantly reduce the interrupt load under high traffic volume.
I guess there's another obvious question that I forgot: Do you have the 3ware cache enabled or disabled? Are your ext3 filesystems mounted with the 'noatime' option?
Regards,
Ian Morgan
Signature · 5 lines
-------------------------------------------------------------------
Ian E. Morgan Vice President & C.O.O. Webcon, Inc.
imorgan at webcon dot ca PGP: #2DA40D07 www.webcon.ca
* Customized Linux network solutions for your business *
-------------------------------------------------------------------Quoted 251 lines · subbie subbie
Dear Ian,
'noapic' was a recommendation by 3Ware / AMCC tech
support. It did not help at all, as expected.
Unfortunately they did not have any other recommendations.I've now removed 'noapic' and unfortunately nothing
has changed, really. See current stats below.# cat /proc/interrupts CPU0 CPU1 0: 64713875 355 IO-APIC-edge timer 2: 0 0 XT-PIC cascade 8: 3 1 IO-APIC-edge rtc 14: 7 6 IO-APIC-edge ide0 16: 176847225 191855106 IO-APIC-level eth0 18: 499139 336893 IO-APIC-level libata 48: 31491551 22761438 IO-APIC-level 3w-9xxx NMI: 0 0 LOC: 64049632 64155206 ERR: 0 MIS: 0# uptime 08:39:14 up 2 days, 23:54, 8 users, load average: 0.16, 0.13, 0.07I have also tried playing with the parameters our friend Ville has mentioned in his post, nothing has come out of it.
I'm willing to give any developer here access to my production machine so that they can see the situation
first hand. Performance is just aweful.I'm planning to ditch RAID5 on this card and try JBOD and in spreading files evenly across my 12 disks, hopefully this would give some benifit.
Something is very wrong with this card / driver / firmware and or kernel combination, hopefully someone can help out.
Much appreciated
Quoted 29 lines · --- Ian Morgan
Why are you booting with 'noapic'.. in my experience that will seriously
impact interrupt performance. Use the APIC if you've got it, which in this
case you definitely do.Yes, having your gigabit NIC and RAID controller on the same IRQ (in PIC
mode) could definitely me a source of trouble.In your web server testing, were you using an external traffic generator or
an on-host process? If you try on-host (eliminating the network throughput
and related interrupts) does performance improve?So two biggest suggestions:
- Use the APIC. It is your friend.
- It looks like the 3ware card and gigabit nic are on different busses, but
the pirq lines are being routed to the same legacy interrupt in PIC mode. So
APIC mode should avoid that problem. If the controller and nic are actually
on the same bus, separate them.Quoted 5 lines
Regards,
Ian Morgan--
-------------------------------------------------------------------
Quoted 7 lines
Ian E. Morgan Vice President & C.O.O.
Webcon, Inc.
imorgan at webcon dot ca PGP: #2DA40D07
www.webcon.ca
* Customized Linux network solutions for your
business *-------------------------------------------------------------------
Quoted 160 lines · subbie subbie
Quoted 6 lines
Dear list,
After almost two weeks of experimentation, google searches and reading of posts, bug reports and discussions I'm still far from an answer. I'm
hoping
Quoted 4 lines
someone on this list could shed some light on the subject.
I'm using a 3Ware 9500S-12 card and am able to
produce
Quoted 2 lines
up to 400MB/s sustained read from my 12-disk 4.1TB RAID5 SATA array, 128MB cache onboard, ext3
formatted.
Quoted 5 lines
All is well when performing a single read -- it
works nice and fast.The system is a web server, serving mid-size files (50MB, each, on average). All hell breaks loose
when
Quoted 1 line
doing many concurrent reads, anywhere between 200
to
Quoted 1 line
400 concurrent streams things simply grind to a
halt
Quoted 5 lines
and the system transfers a maximum of 12-14MB/s.
I'm in the process of clearing up the array (this would take some time) and restructuring it to JBOD mode in order to use each disk individually. I
will
Quoted 2 lines
use a filesystem more suitable to streaming large files, such as XFS. But this would take time and
I
Quoted 1 line
would very much appreciate the advice of people in
the
Quoted 1 line
know if this is going to help at all. It's hard
for
Quoted 3 lines
me to make extreme experimentation (deleting, formatting, reformatting) as this is a productio n system with many files that I have no other place
to
Quoted 5 lines
dump until they can be safely removed. Though I'm working on dumping them slowly to other, remote, machines.
I'm running the latest kernel, 2.6.13.2 and the
latest
Quoted 1 line
3Ware driver, taken from the 3ware.com web site
which
Quoted 1 line
upon insmod, updates the card's firmware to the
latest
Quoted 3 lines
version as well.
In my experiments, I've tried using larger
readahead,
Quoted 2 lines
currently at 16k (this helps, higher values do not seem to help much), using the deadline scheduler
for
Quoted 3 lines
this device, booting the system with the 'noapic' option and playing with a bunch of VM tunable parameters which I'm not sure that I should really
be
Quoted 2 lines
touching. At the moment only the readahead modification is used as the other stuff simply
didn't
Quoted 3 lines
help at all.
With the stock kernel shipped with my
distribution,
Quoted 2 lines
2.6.8 and its old 3ware driver things were just as worse but manifested themselves differently.
The
Quoted 1 line
system was visibly (top, vmstat...) spending most
of
Quoted 10 lines
its time in io-wait and load average was extremely
high, in the area of 10 to 20. With the recent
kernel and driver mentioned above, the excessive io-wait and load seems to have been resolved and observed loadavg is between 1 and 4.I don't have much experience with systems that are supposed to stream many files concurrently off a hardware RAID of this configuration, but my gut feeling is that something is very wrong and I
should
Quoted 7 lines
be seeing a much higher read throughput.
Trying to preempt people's questions I've tried to include as much information as possible, a lot of stuff is pasted below.
I've just seen that the 3ware driver shares the
same
Quoted 1 line
IRQ with my ethernet card, which has got me a
little
Quoted 10 lines
worried, should I be?
System uptime, exactly 1 day:
# cat /proc/interrupts CPU0 CPU1 0: 21619638 0 XT-PIC timer 2: 0 0 XT-PIC cascade 8: 4 0 XT-PIC rtc 10: 268753224 0 XT-PIC3w-9xxx,
Quoted 8 lines
eth0
14: 11 0 XT-PIC ide0 15: 337881 0 XT-PIC libata NMI: 0 0 LOC: 21110402 21557685 ERR: 0 MIS: 0Quoted 4 lines
# free total used free shared buffers cached Mem: 2075260 2024724 505360
Quoted 37 lines
5184 1388408
-/+ buffers/cache: 631132 1444128
Swap: 3903784 0 3903784# vmstat -n 1 (output of the last few seconds): procs -----------memory---------- ---swap-- -----io---- --system-- ----cpu---- 0 0 0 49932 4760 1392980 0 0 15636 32 3169 3697 4 6 30 60 0 0 0 50816 4752 1392376 0 0 5844 0 3114 3929 3 5 91 1 0 0 0 50924 4772 1391404 0 0 9360 0 3187 4348 6 6 76 13 0 2 0 50552 4780 1391532 0 0 24976 44 4077 3906 3 7 65 25 0 1 0 50444 4780 1392688 0 0 20192 0 5048 3914 7 8 56 30 0 1 0 50568 4756 1392508 0 0 21248 0 4060 3603 4 6 48 41 0 0 0 50704 4724 1392268 0 0 30004 0 3834 3369 4 9 65 22 0 3 0 50556 4728 1392468 0 0 3248 1832 2974 4514 2 5 58 35 0 3 0 50308 4724 1392200 0 0 1288 336 1766 1886 1 3 50 47 0 4 0 50308 4732 1391852 0 0 2300 408 1919 2158 0 3 51 46 0 4 0 50556 4736 1390692 0 0 1856 532 1488 1846 3 1 50 46 0 3 0 50680 4740 1390620 0 0 4016 1296 1577 1682 2 2 50 47 0 3 0 50432 4752 1391628 0 0 2180 72 1730 1945 2 2 51 46 2 2 0 49924 4772 1391540 0 0 44372 564 3403 2847 4 5 50 42 0 0 0 50684 4784 1391528 0 0 28640 216 3804 3847 7 8 69 16
Quoted 9 lines · --- "Ian E. Morgan
I have seen some systems on which IRQ load balancing can have a detrimental
effect on some devices such as gigabit Ethernet etc.You could try disabling both the irqbalance userspace daemon (if that's part
of your distribution), and in-kernel IRQ balancing, if enabled
(CONFIG_IRQBALANCE).
I don't have a userspace daemon for that, but I'll try the kernel option.
Quoted 5 lines
For your NIC, try enabling NAPI interrupt mitigation, if available. This
will significantly reduce the interrupt load under high traffic volume.
It's always enabled in my configs.
Quoted 5 lines
I guess there's another obvious question that I
forgot: Do you have the
3ware cache enabled or disabled? Are your ext3
filesystems mounted with the
'noatime' option?
Write caching is enabled. I don't have much activity across thousands of files so noatime is less ciritical, but the RAID volume is still mounted noatime.
So basically I'll try the irq load balancing and see whath happens.
Thanks
__________________________________
Yahoo! Mail - PC Magazine Editors' Choice 2005
http://mail.yahoo.com
Quoted 7 lines · you [subbie subbie]
Dear list,
After almost two weeks of experimentation, google searches and reading of posts, bug reports and discussions I'm still far from an answer. I'm hoping someone on this list could shed some light on the subject.
Hi,
We're having similar problems with 9500S-4LP and two Hitachi 250GB SATA disks.
Currently we are running 2.6.12.5 and its 3w-9xxx driver. We have tried numerous 2.4 (Red Hat and kernel.org) and 2.6 kernels and 3w-9xxx drivers (kernel and 3ware.com).
The results it more or less the same: on 2.4 it corrupts data and is slow, on 2.6 it doesn't corrupt data, but is slow.
Our workload is VMWare GSX server. Multiple readers/writers will grind the performance to halt.
We've tried:
http://www.linux-mag.com/index2.php?option=com_content&task=view&id=2033&Itemid=2304&pop=1&page=0 blockdev -setra 16384 /dev/sda
- different kernel IO schedulers
- parameters such as
blockdev --setra 8192 /dev/vg0/root
echo 300 > /sys/block/sda/queue/iosched/read_expire echo 5 > /sys/block/sda/queue/iosched/writes_starved
None of this seems to make much difference.
Please drop me a note if you ever get any light on this issue...
-- v --
In article <[email protected]>,
Quoted 11 lines · subbie subbie
I'm using a 3Ware 9500S-12 card and am able to produce up to 400MB/s sustained read from my 12-disk 4.1TB RAID5 SATA array, 128MB cache onboard, ext3 formatted.
All is well when performing a single read -- it
works nice and fast.The system is a web server, serving mid-size files (50MB, each, on average). All hell breaks loose when doing many concurrent reads, anywhere between 200 to 400 concurrent streams things simply grind to a halt and the system transfers a maximum of 12-14MB/s.
There are a couple of things you should do:
1. Use the CFQ I/O scheduler, and increase nr-requests:
echo cfq > /sys/block/hda/queue/scheduler echo 1024 > /sys/block/hda/queue/nr_requests
2. Make sure that your filesystem knows about the stripe size and number of disks in the array. E.g. for a raid5 array with a stripe size of 64K and 6 disks (effectively 5, because in every stripe-set there is on disk doing parity):
# ext3 fs, 5 disks, 64K stripe, units in 4K blocks mkfs -text3 -E stride=$((64/4))
# xfs, 5 disks, 64K stripe, units in 512 bytes mkfs -txfs -d sunit=$((64*2)) -d swidth=$((5*64*2))
3. Don't use partitions. Partions do not start on a multiple of the (stripe_size * nr_disks), so your I/O will be misaligned and the settings in (2) will have no or an adverse effect. If you must use partitions, either build them manually with sfdisk so that partitions do start on that multiple, or use LVM.
4. Reconsider your stripe size for streaming large files. If you have say 4 disks, and a 64K
stripe size, then a read of a block of 256K will busy all 4 disks. Many simultaneous threads reading blocks of 256K will result in trashings disks as they all want to read from all 4 disks .. so in that case, using a stripesize of 256K will make things better. One read of 256K (in the ideal, aligned case) will just keep one disk busy. 4 reads can happen in parallel without trashing. Esp. in this case, you need the alignment I talked about in (3).
5. Defragment the files.
If the files are written sequentially, they will not be fragmented. But if they were stored by writing to thousands of them appending a few K at a time in round-robin fashion, you need to defragment.. in the case of XFS, run xfs_fsr every so often.
Good luck,
Mike.