3ware 8006-2LP on Linux 2.6 drive error, seagate disks
Hello,
Recently I've come across a lot of problems with 3ware controller on Linux 2.6.15.4. Everything is in the Thomas-Krenn SR2400 server running on Debian.
3WARE DEVICE:
driver: 1.26.02.001
model: 8006-2LP
firmware: FE8S 1.05.00.068
bios: BE7X 1.08.00.048
DISKS:
2x Seagate ST3300831AS SATA 300GB
I used tw_cli (AMCC/3ware CLI (version 2.00.03.013)) to create RAID1 unit. After running cfdisk raid degraded and it can't be rebuilded. Next I tried to make JBOD units for testing. A 3ware driver was compiled into the kernel and also as a module.
ERRORS:
Apr 26 15:07:10 krenn kernel: 3w-xxxx: scsi2: Command failed: status = 0xc7, flags = 0xc, unit #0. Apr 26 15:07:14 krenn kernel: 3w-xxxx: scsi2: AEN: ERROR: Drive error: Port #0. Apr 26 15:07:15 krenn kernel: 3w-xxxx: scsi2: Command failed: status = 0xc7, flags = 0xc, unit #0. Apr 26 15:07:20 krenn kernel: 3w-xxxx: scsi2: Command failed: status = 0xc7, flags = 0xc, unit #0. Apr 26 15:07:25 krenn kernel: 3w-xxxx: scsi2: Command failed: status = 0xc7, flags = 0xc, unit #0. Apr 26 15:07:30 krenn kernel: 3w-xxxx: scsi2: Command failed: status = 0xc7, flags = 0xc, unit #0. Apr 26 15:07:35 krenn kernel: 3w-xxxx: scsi2: Command failed: status = 0xc7, flags = 0xc, unit #0. Apr 26 15:07:38 krenn kernel: sd 2:0:0:0: WARNING: Command (0x28) timed out,
resetting card.
It looks like some incompatibility with driver. Cables and disks are new, no badblocks. Tommorow I will try to compile driver from 3ware website with 2.4 kernel.
Thanks in advance.
Signature · 4 lines
Marcin Hlybin, [email protected] Sys/Net Administrator, tel. +48 12 2523 402 SoftwareMind, www.softwaremind.pl | Where quality meets the future
Quoted 2 lines · Marcin Hlybin
Apr 26 15:07:10 krenn kernel: 3w-xxxx: scsi2: Command failed: status = 0xc7,flags =
0xc, unit #0.
Ok, I've solved my problem by changing SATA cables. I have tested controller with massive I/O operations with both enabled and disabled write-caching. Admittedly next day TK server crashed with NMI, parity errors and so on, but now I have new mainboard, new riser and everything works just fine. I use tw_cli to maintain the RAID.
Regards
Signature · 4 lines
Marcin Hlybin, marcin.hlybin (at) swmind.com Sys/Net Administrator, tel. +48 12 2523 402 SoftwareMind, www.softwaremind.pl | Where quality meets the future