lp8000 and 2.6.18-rc6
Hello,
I have a problem with the Emulex LP8000 lpfc driver:
- the kernel module loads fine and reports 4 luns from the storage (Clariion 4700), also listed in /proc/scsi/scsi, but
- there is no way to have a SCSI device attached (sdb, sdc, ...), even runing rescan-scsi-bus. The disks are not listed with fdisk -l.
It's the first time I use this setup... Am I missing something?
Thank you for any help.
Alberto
==== Uname -a:
Linux novantatre 2.6.18-rc6 #1 SMP Sat Sep 9 09:46:54 CEST 2006 i686 GNU/Linux
==== lsmod:
Module Size Used by lpfc 145600 0 scsi_transport_fc 25568 1 lpfc iscsi_tcp 19808 1 libiscsi 17504 1 iscsi_tcp
scsi_transport_iscsi 23244 3 iscsi_tcp,libiscsi
skge 31312 0
[...]
==== From dmesg:
Emulex LightPulse Fibre Channel SCSI driver 8.1.9 Copyright(c) 2004-2006 Emulex. All rights reserved.
PCI: Enabling device 0000:04:01.0 (0158 -> 015b)
ACPI: PCI Interrupt 0000:04:01.0[A] -> GSI 52 (level, low) -> IRQ 23 scsi6 : on PCI bus 04 device 08 irq 23
lpfc 0000:04:01.0: 0:1303 Link Up Event x1 received Data: x1 x1 x0 x0
Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04
===== from /proc/scsi/scsi:
Host: scsi6 Channel: 00 Id: 00 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 01 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 02 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 03 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Signature · 3 lines
Alberto Cammozzo System/Network Manager Universita` di Padova -IT
It's not an LP8000 issue... It's a Clariion issue... The inquiry data for the 4 target ports looks only partially formed (no PID, odd SCSI rev). The guess is that the clariion isn't set up to export any real luns to you yet. See if there's lun-masking (or selective presentation) that you have to enable on the clariion based on the wwpn of the adapter.
-- james s
Quoted 57 lines · Alberto Cammozzo
Hello,
I have a problem with the Emulex LP8000 lpfc driver:
- the kernel module loads fine and reports 4 luns from the storage (Clariion 4700), also listed in/proc/scsi/scsi, but
- there is no way to have a SCSI device attached (sdb, sdc, ...), even runing rescan-scsi-bus. The disks are not listed with fdisk -l.It's the first time I use this setup... Am I missing something?
Thank you for any help.
Alberto
==== Uname -a:
Linux novantatre 2.6.18-rc6 #1 SMP Sat Sep 9 09:46:54 CEST 2006 i686 GNU/Linux==== lsmod:
Module Size Used by lpfc 145600 0 scsi_transport_fc 25568 1 lpfc iscsi_tcp 19808 1 libiscsi 17504 1 iscsi_tcp
scsi_transport_iscsi23244 3 iscsi_tcp,libiscsi
skge 31312 0 [...]==== From dmesg:
Emulex LightPulse Fibre Channel SCSI driver 8.1.9 Copyright(c) 2004-2006 Emulex. All rights reserved.
PCI: Enabling device 0000:04:01.0 (0158 -> 015b)
ACPI: PCI Interrupt 0000:04:01.0[A] -> GSI 52 (level, low) -> IRQ 23 scsi6 : on PCI bus 04 device 08 irq 23
lpfc 0000:04:01.0: 0:1303 Link Up Event x1 received Data: x1 x1 x0 x0Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04===== from
/proc/scsi/scsi:
Host: scsi6 Channel: 00 Id: 00 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 01 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 02 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 03 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Quoted 6 lines · James Smart
It's not an LP8000 issue... It's a Clariion issue... The inquiry data for the 4 target ports looks only partially formed (no PID, odd SCSI rev). The guess is that the clariion isn't set up to export any real luns to you yet. See if there's lun-masking (or selective presentation) that you have to enable on the clariion based on the wwpn of the adapter.
Thank you James,
I'll follow you suggestion.
I forgot to say that a Windows client sees the same luns and mounts them fine. Perhaps W. is less picky about permissions...
Alberto
Quoted 65 lines
-- james s
Quoted 61 lines · Alberto Cammozzo
Hello,
I have a problem with the Emulex LP8000 lpfc driver:
- the kernel module loads fine and reports 4 luns from the storage (Clariion 4700), also listed in/proc/scsi/scsi, but
- there is no way to have a SCSI device attached (sdb, sdc, ...), even runing rescan-scsi-bus. The disks are not listed with fdisk -l.It's the first time I use this setup... Am I missing something?
Thank you for any help.
Alberto
==== Uname -a:
Linux novantatre 2.6.18-rc6 #1 SMP Sat Sep 9 09:46:54 CEST 2006 i686 GNU/Linux==== lsmod:
Module Size Used by lpfc 145600 0 scsi_transport_fc 25568 1 lpfc iscsi_tcp 19808 1 libiscsi 17504 1 iscsi_tcp
scsi_transport_iscsi23244 3 iscsi_tcp,libiscsi
skge 31312 0
[...]==== From dmesg:
Emulex LightPulse Fibre Channel SCSI driver 8.1.9 Copyright(c) 2004-2006 Emulex. All rights reserved.
PCI: Enabling device 0000:04:01.0 (0158 -> 015b)
ACPI: PCI Interrupt 0000:04:01.0[A] -> GSI 52 (level, low) -> IRQ 23 scsi6 : on PCI bus 04 device 08 irq 23
lpfc 0000:04:01.0: 0:1303 Link Up Event x1 received Data: x1 x1 x0 x0Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04 Vendor: DGC Model: Rev: 0850 Type: Direct-Access ANSI SCSI revision: 04===== from
/proc/scsi/scsi:
Host: scsi6 Channel: 00 Id: 00 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 01 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 02 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Host: scsi6 Channel: 00 Id: 03 Lun: 00
Vendor: DGC Model: Rev: 0850
Type: Direct-Access ANSI SCSI revision: 04
Signature · 3 lines
Alberto Cammozzo V.Cesare Battisti 241/243. PADOVA ITALY System/Network Manager e-mail : [email protected] Universita` di Padova -IT tel : +39 49 8274175