fscache: kconfig tidying
PATCH 2/2 fscache: kconfig tidying
Use select for CONFIG_FSCACHE to fix the dependency mess
Signed-off-by Christoph Hellwig <[email protected]>
fs/Kconfig +4 -5
@@ -533,8 +533,7 @@ menu "Caches" config FSCACHE - tristate "General filesystem cache manager" - depends on EXPERIMENTAL + tristate help This option enables a generic filesystem caching manager that can be used by various network and other filesystems to cache data
@@ -545,7 +544,7 @@ config CACHEFILES tristate "Filesystem caching on files" - depends on FSCACHE + select FSCACHE help This permits use of a mounted filesystem as a cache for other filesystems - primarily networking filesystems - thus allowing fast
@@ -1527,7 +1526,7 @@ config NFS_FSCACHE bool "Provide NFS client caching support (EXPERIMENTAL)" depends on EXPERIMENTAL - depends on NFS_FS=m && FSCACHE || NFS_FS=y && FSCACHE=y + select FSCACHE help Say Y here if you want NFS data to be cached locally on disc through the general filesystem cache manager
@@ -1971,7 +1970,7 @@ config AFS_FSCACHE bool "Provide AFS client caching support (EXPERIMENTAL)" depends on EXPERIMENTAL - depends on AFS_FS=m && FSCACHE || AFS_FS=y && FSCACHE=y + select FSCACHE help Say Y here if you want AFS data to be cached locally on disk through the generic filesystem cache manager