Use diag instead of ccw reipl.
From: Michael Holzheu <[email protected]>
[S390] Use diag instead of ccw reipl.
Since the diag 308 reipl method is superior to the ccw method, we should use it whenever it is possible. We can do that, if the user has not specified a new reipl ccw device and the system has been ipled from a ccw device.
Signed-off-by Michael Holzheu <[email protected]>
Signed-off-by Martin Schwidefsky <[email protected]>
---
arch/s390/kernel/ipl.c | 2 ++ 1 files changed, 2 insertions(+)
arch/s390/kernel/ipl.c +2 -0
@@ -664,6 +664,8 @@ void do_reipl(void)switch (reipl_method) {case IPL_METHOD_CCW_CIO : devid.devno = reipl_block_ccw->ipl_info.ccw.devno; +if (ipl_get_type () ==IPL_TYPE_CCW && devid.devno == ipl_devno) +diag308 (DIAG308_IPL ,NULL ); devid.ssid =0 ;reipl_ccw_dev (&devid);break ;