FB: sync with N800 tree (fix RFBI frequency lookup in tearing sync setup)
PATCH 4/4 FB: sync with N800 tree (fix RFBI frequency lookup in tearing sync setup)
Different DPLL multiplier / divider pairs can result in frequencies that are not exact matches of the values given by TI. When looking up the table of known L4 / DSS1 values allow for a small difference.
Signed-off-by Imre Deak <[email protected]>
--- drivers/video/omap/rfbi.c | 7 +++++-- 1 files changed, 5 insertions(+), 2 deletions(-)
drivers/video/omap/rfbi.c +5 -2
@@ -213,8 +213,11 @@ static unsigned long rfbi_get_max_tx_rate(void) dss1_rate =clk_get_rate (rfbi.dss1_fck) /1000000 ;for (i =0 ; i <ARRAY_SIZE (ftab); i++) { -if (ftab[i].l4_clk == l4_rate && - ftab[i].dss1_clk == dss1_rate) { +/* Use a window instead of an exact match, to account +* for different DPLL multiplier / divider pairs. +*/ +if (abs (ftab[i].l4_clk - l4_rate) <3 && +abs (ftab[i].dss1_clk - dss1_rate) <3 ) { min_l4_ticks = ftab[i].min_l4_ticks;break ; }
Signature · 1 line
1.4.4.3.GIT