cluster/fence/man fenced.8
CVSROOT: /cvs/cluster
Module name: cluster
Changes by: teigland at sourceware.org 2007-08-16 21:02:24
Modified files:
fence/man : fenced.8
Log message:
mention fencing override, describe the structure of node fencing parameters in cluster.conf, point to web site for device-specific documentation
fence/man/fenced.8 +81 -8
@@ -108,6 +108,13 @@ are fenced by power cycling. If nodes are fenced by disabling their SAN access, then unnecessarily fencing a node is usually less disruptive. +.SS Fencing override + +If a fencing device fails, the agent may repeatedly return errors as +fenced tries to fence a failed node. In this case, the admin can manually +reset the failed node, and then use fence_ack_manual to tell fenced to +continue without fencing the node. + .SH CONFIGURATION FILE Fencing daemon behavior can be controlled by setting options in the cluster.conf file under the section <fence_daemon> </fence_daemon>. See
@@ -118,27 +125,93 @@ Post-join delay is the number of seconds the daemon will wait before fencing any victims after a node joins the domain. - <fence_daemon post_join_delay="6"> - </fence_daemon> + <fence_daemon post_join_delay="6"/> Post-fail delay is the number of seconds the daemon will wait before fencing any victims after a domain member fails. - <fence_daemon post_fail_delay="0"> - </fence_daemon> + <fence_daemon post_fail_delay="0"/> Clean-start is used to prevent any startup fencing the daemon might do. It indicates that the daemon should assume all nodes are in a clean state to start. - <fence_daemon clean_start="0"> - </fence_daemon> + <fence_daemon clean_start="0"/> Override-path is the location of a FIFO used for communication between fenced and fence_ack_manual. - <fence_daemon override_path="/var/run/cluster/fenced_override"> - </fence_daemon> + <fence_daemon override_path="/var/run/cluster/fenced_override"/> + +.SS Per-node fencing settings + +The per-node fencing configuration can become complex and is largely +specific to the hardware being used. The general framework begins like +this: + + <clusternodes> + + <clusternode name="node1" nodeid="1"> + <fence> + </fence> + </clusternode> + + <clusternode name="node2" nodeid="2"> + <fence> + </fence> + </clusternode> + + ... + </clusternodes> + +The simple fragment above is a valid configuration: there is no way to +fence these nodes. If one of these nodes is in the fence domain and +fails, fenced will repeatedly fail in its attempts to fence it. The admin +will need to manually reset the failed node and then use fence_ack_manual +to tell fenced to continue on without fencing it (see override above). + +There is typically a single method used to fence each node, where the +method refers to a specific device listed in the separate <fencedevices> +section and then lists any node-specific parameters related to using the +device. + + <clusternodes> + + <clusternode name="node1" nodeid="1"> + <fence> + <method name="single"> + <device name="myswitch" hw-specific-param="x"/> + </method> + </fence> + </clusternode> + + <clusternode name="node2" nodeid="2"> + <fence> + <method name="single"> + <device name="myswitch" hw-specific-param="y"/> + </method> + </fence> + </clusternode> + + ... + </clusternodes> + +.SS Fence device settings + +This section defines properties of the devices used to fence nodes. There +may be one or more devices listed. The per-node fencing sections above +reference one of these fence devices by name. + + <fencedevices> + <fencedevice name="myswitch" ipaddr="1.2.3.4" .../> + </fencedevices> + +.SS Hardware-specific settings + +Find documentation for configuring specific devices, multiple methods per +node, and redundant-power/dual-path hardware at +.BR +http://sources.redhat.com/cluster/ .SH OPTIONS Command line options override corresonding values in cluster.conf.