CPU usage for 10Gbps UDP transfers
Hello,
is it expected that application sending 8900bytes datagram through 10Gbps NIC utilizes CPU to 100% and similarly the receiver also utilizes CPU to 100%. Is it something wrong or this is quite OK?
(The box is dual single core Opteron 2.4GHz with Myricom 10GE NIC.)
Signature · 1 line
Lukáš Hejtmánek
Quoted 9 lines
Hello,
is it expected that application sending 8900bytes datagram through 10Gbps NIC
utilizes CPU to 100% and similarly the receiver also utilizes CPU to 100%. Is it something wrong or this is quite OK?(The box is dual single core Opteron 2.4GHz with Myricom 10GE NIC.)
It's extremely hard to understand what it is that you're saying. Perhaps if I explain the two things I first thought when you posted this, it will explain why your post is vague:
1) *Any* task will use the CPU to 100% while it's running. Even if you ask the computer to add 1 to 1, while it's doing that add for you, the task is using 100% of the CPU.
2) If you ask the CPU to do any task over and over again as quickly as it can, and it has nothing else to do, that task will get 100% of the CPU?
So what are you really asking?
DS
Quoted 14 lines · David Schwartz
Quoted 9 lines
Hello,
is it expected that application sending 8900bytes datagram through 10Gbps NIC
utilizes CPU to 100% and similarly the receiver also utilizes CPU to 100%. Is it something wrong or this is quite OK?(The box is dual single core Opteron 2.4GHz with Myricom 10GE NIC.)
It's extremely hard to understand what it is that you're saying. Perhaps if I explain the two things I first thought when you posted this, it will explain why your post is vague:
Quoted 8 lines
1) *Any* task will use the CPU to 100% while it's running. Even if you ask the computer to add 1 to 1, while it's doing that add for you, the task is using 100% of the CPU.
2) If you ask the CPU to do any task over and over again as quickly as it can, and it has nothing else to do, that task will get 100% of the CPU?
So what are you really asking?
I think he means that his application saturates the 10Gbps NIC with 8900 bytes datagrams and it consumes 100% of the CPU while doing this, and it's the same on the receiver side. I'm not surprized at all, considering that it means around 140kpps, or pauses of about 7 microseconds between each frame. Those pauses are too short to do anything else, resulting in the task to appear as taking 100% CPU. But IMHO, that does not mean that the machine is saturated; If the task had more work to do between each datagram, it would possibly be done. Same if it had to send shorter frames twice as fast.
Willy
Quoted 7 lines · Lukas Hejtmanek
Hello,
is it expected that application sending 8900bytes datagram through 10Gbps NIC utilizes CPU to 100% and similarly the receiver also utilizes CPU to 100%. Is it something wrong or this is quite OK?
(The box is dual single core Opteron 2.4GHz with Myricom 10GE NIC.)
Every time a new generation of ethernet comes out, its peak throughput exceeds the memory/CPU/IO capacity of commodity hardware available at the time. This is normal. Of course, you may not be saturating the link, and it may be possible to tune the driver to improve your throughput, but you'll still be saturating a CPU on that hardware.
-- Chris