Skip to contentSkip to conversation

RFC4303 (IPsec/ESP) auditing requirements

DISCUSSION Paul Moore 2 participants 4 messages Dec 5, 2007 – Dec 6, 2007

lore
Share & tools
lore

Paul Moore

author
#0 lore raw

Hello all,

I'm looking at RFC4303 at some of the auditing requirements and one of the gaps between what the specification requires and what we currently provide involves the SA's sequence number and the IPv6 flow ID. According the list of existing audit fields[1] there doesn't appear to any fields which are a good match. With that in mind I'd like to propose two new fields:

* seqno - sequence number
* flowid - flow id

Any comments, objections, suggestions?

[1] http://people.redhat.com/sgrubb/audit/audit-parse.txt

Signature · 2 lines
paul moore
linux security @ hp
author
#1 lore raw
Quoted 10 lines · Paul Moore

Hello all,

I'm looking at RFC4303 at some of the auditing requirements and one of the gaps between what the specification requires and what we currently provide involves the SA's sequence number and the IPv6 flow ID. According the list of existing audit fields[1] there doesn't appear to any fields which are a good match. With that in mind I'd like to propose two new fields:

* seqno - sequence number
* flowid - flow id

Scratch the 'flowid' name, the more I look at things we should probably go with 'flowlbl'.

Quoted 3 lines

Any comments, objections, suggestions?

[1] http://people.redhat.com/sgrubb/audit/audit-parse.txt

Signature · 2 lines
paul moore
linux security @ hp
#2 lore raw
In reply to Paul Moore
Quoted 8 lines · Paul Moore

Hello all,

I'm looking at RFC4303 at some of the auditing requirements and one of the gaps between what the specification requires and what we currently provide involves the SA's sequence number and the IPv6 flow ID. According the list of existing audit fields[1] there doesn't appear to any fields which are a good match. With that in mind I'd like to propose two new fields:

Quoted 4 lines

* seqno - sequence number
* flowid - flow id

Any comments, objections, suggestions?

I see a note from Sep 12 or so from Joy Latten that was talking about adding support for rfcs430[1-3] - are you two collaborating or working at cross purposes? Are any other fields/calls needed to complete the set? (Feel free to just handwave a "Somebody should add XYZ in 2.6.N+3" if warranted)

Other than that, the RFC looks sane, and has a rfc2119-SHOULD for those fields, so it certainly sounds like a good idea. Besides, I *know* that if we don't, at some point I'm going to be doing forensics or debugging, and cursing the fact that not all my sensors reported flowid to cross-correlate on :)

author
#3 lore raw
Quoted 10 lines · On Thursday 06 December 2007 1:25:50 pm [email protected] wrote:
Quoted 9 lines · Paul Moore

Hello all,

I'm looking at RFC4303 at some of the auditing requirements and one of the gaps between what the specification requires and what we currently provide involves the SA's sequence number and the IPv6 flow ID. According the list of existing audit fields[1] there doesn't appear to any fields which are a good match. With that in mind I'd like to propose two new fields:

Quoted 8 lines
Quoted 4 lines

* seqno - sequence number
* flowid - flow id

Any comments, objections, suggestions?

I see a note from Sep 12 or so from Joy Latten that was talking about adding support for rfcs430[1-3] - are you two collaborating or working at cross purposes?

Joy who?

;)

The Linux Foundation, of which both HP (my employer) and IBM (Joy's employer) are members, is currently going through an IPv6 "gap analysis" trying to bring the Linux IPv6 implementation more in line with the various IPv6 specifications. IPsec, including RFC4303, is part of this effort.

Needless to say there are several people involved (I only know a small handful) and I'm just trying to help out by taking care of the auditing requirements in RFC4303.

Quoted 3 lines

Are any other fields/calls needed to complete the set? (Feel free to just handwave a "Somebody should add XYZ in 2.6.N+3" if warranted)

Not according to RFC4303, but let's do some vague handwaving anyway :)

Quoted 5 lines

Other than that, the RFC looks sane, and has a rfc2119-SHOULD for those fields, so it certainly sounds like a good idea. Besides, I *know* that if we don't, at some point I'm going to be doing forensics or debugging, and cursing the fact that not all my sensors reported flowid to cross-correlate on :)

:)

Signature · 2 lines
paul moore