Not use absolute MBAR in MPC5200 Bestcomm firmware
PATCH 1/1 Not use absolute MBAR in MPC5200 Bestcomm firmware
I hope now everything is ok with the format.
Best Regards
Oliver Weber
Signed-off-by Oliver Weber <[email protected]>
cpu/mpc5xxx/firmware_sc_task_bestcomm.impl.S +4 -4
@@ -23,7 +23,7 @@ scEthernetRecv_Entry: /* Task 0 */ .long 0x00000000 .long 0x00000000 .long scEthernetRecv_CSave - taskTable /* Task 0 context save space */ -.long 0xf0000000 +.long CFG_MBAR .globl scEthernetXmit_Entry scEthernetXmit_Entry: /* Task 1 */ .long scEthernetXmit_TDT - taskTable /* Task 1 Descriptor Table */
@@ -33,7 +33,7 @@ scEthernetXmit_Entry: /* Task 1 */ .long 0x00000000 .long 0x00000000 .long scEthernetXmit_CSave - taskTable /* Task 1 context save space */ -.long 0xf0000000 +.long CFG_MBAR .globl scEthernetRecv_TDT
@@ -151,7 +151,7 @@ scEthernetRecv_VarTab: /* Task 0 Variabl .long 0x00000000 /* var[6] */ .long 0x00000000 /* var[7] */ .long 0x00000000 /* var[8] */ -.long 0xf0008800 /* var[9] */ +.long (CFG_MBAR + 0x8800) /* var[9] */ .long 0x00000008 /* var[10] */ .long 0x0000000c /* var[11] */ .long 0x80000000 /* var[12] */
@@ -190,7 +190,7 @@ scEthernetXmit_VarTab: /* Task 1 Variabl .long 0x00000000 /* var[8] */ .long 0x00000000 /* var[9] */ .long 0x00000000 /* var[10] */ -.long 0xf0008800 /* var[11] */ +.long (CFG_MBAR + 0x8800) /* var[11] */ .long 0x00000000 /* var[12] */ .long 0x80000000 /* var[13] */ .long 0x10000000 /* var[14] */
Signature · 2 lines
Der GMX SmartSurfer hilft bis zu 70% Ihrer Onlinekosten zu sparen! Ideal f?r Modem und ISDN: http://www.gmx.net/de/go/smartsurfer
Wolfgang Denk
AppliedPATCH 1/1 Not use absolute MBAR in MPC5200 Bestcomm firmware
Quoted 7 lines · In message <[email protected]> you wrote:
I hope now everything is ok with the format.
Best Regards
Oliver Weber
Signed-off-by Oliver Weber <[email protected]>
Applied, thanks.
Best regards,
Wolfgang Denk
Signature · 5 lines
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de Always try to do things in chronological order; it's less confusing that way.