ibmpex: Correct power use multipliers for QS2x blade
PATCH 1/1 ibmpex: Correct power use multipliers for QS2x blade
The QS2x blades ships with v2.54 of the firmware, which use the same multiplier for all power meters.
Signed-off-by Darrick J. Wong <[email protected]>
---
drivers/hwmon/ibmpex.c | 11 ++++++++--- 1 files changed, 8 insertions(+), 3 deletions(-)
drivers/hwmon/ibmpex.c +8 -2
@@ -327,10 +327,14 @@ static int is_temp_sensor(const char *sensor_id, int len)return 0 ; } -static int power_sensor_multiplier (const char *sensor_id,int len) +static int power_sensor_multiplier (struct ibmpex_bmc_data *data, +const char *sensor_id,int len) {int i; +if (data->sensor_major =2 ) +return 1000000 ; +for (i =PEX_SENSOR_TYPE_LEN ; i < len -1 ; i++)if (!memcmp (&sensor_id[i], watt_sensor_sig,PEX_MULT_LEN ))return 1000000 ;
@@ -398,8 +402,9 @@ static int ibmpex_find_sensors(struct ibmpex_bmc_data *data) num_power++; sensor_counter = num_power; data->sensors[i].multiplier -power_sensor_multiplier (data->rx_msg_data, - data->rx_msg_len); +power_sensor_multiplier (data, + data->rx_msg_data, + data->rx_msg_len); }else if (is_temp_sensor (data->rx_msg_data, data->rx_msg_len)) { sensor_type =TEMP_SENSOR ;
_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
Quoted 3 lines · On Wed, 12 Mar 2008 18:15:38 -0700 "Darrick J. Wong" <[email protected]> wrote:
The QS2x blades ships with v2.54 of the firmware, which use the same multiplier for all power meters.
Mark has been quiet lately, so I'll scoot these two into 2.6.25.
_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors