ibmpex: Report temperatures in mC, not C.
PATCH 1/1 ibmpex: Report temperatures in mC, not C.
ibmpex's temperature sensors report incorrect units. Apply a conversion factor so that tempertures report correctly. Until now, no systems seemed to report temperatures this way, but evidently QS2x blades do.
Signed-off-by Darrick J. Wong <[email protected]>
---
drivers/hwmon/ibmpex.c | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-)
drivers/hwmon/ibmpex.c +1 -1
@@ -410,7 +410,7 @@ static int ibmpex_find_sensors(struct ibmpex_bmc_data *data) sensor_type =TEMP_SENSOR ; num_temp++; sensor_counter = num_temp; - data->sensors[i].multiplier =1 ; + data->sensors[i].multiplier =1000 ; }else continue ;