spi_s3c24xx driver must init completion
Subsystems (2)
PATCH 3/3 spi_s3c24xx driver must init completion
From: Ben Dooks <[email protected]>
The s3c24xx_spi_txrx() function should initialise the completion each time before using it, otherwise we end up with the possibility of returning success before the interrupt handler has processed all the data.
Signed-off-by Ben Dooks <[email protected]>
Signed-off-by David Brownell <[email protected]>
--- drivers/spi/spi_s3c24xx.c | 3 +++ 1 file changed, 3 insertions(+)
drivers/spi/spi_s3c24xx.c +3 -0
@@ -192,8 +192,11 @@ static int s3c24xx_spi_txrx(struct spi_d hw->len = t->len; hw->count =0 ; +init_completion (&hw->done); +/* send the first byte */ writeb (hw_txbyte (hw,0 ), hw->regs +S3C2410_SPTDAT ); +wait_for_completion (&hw->done);return hw->count;
-------------------------------------------------------------------------