Fix regression in drivers/mtd/cfi_flash.c.
PATCH 1/1 Fix regression in drivers/mtd/cfi_flash.c.
Fix a regression in the 1.3.4 version of drivers/mtd/cfi_flash.c.
Add a case to the new switch statement in flash_real_protect() to make flash chips using the Intel extended command set work again. Also correct a debug printf format-string/argument mismatch.
--- drivers/mtd/cfi_flash.c | 3 ++- 1 files changed, 2 insertions(+), 1 deletions(-)
drivers/mtd/cfi_flash.c +2 -1
@@ -516,7 +516,7 @@ static int flash_isequal (flash_info_t * info, flash_sect_t sect, retval = (flash_read16 (addr) == cword.w);break ;case FLASH_CFI_32BIT : -debug ("is= %8.8lx %8.8lx\n" ,flash_read32 (addr), cword.l); +debug ("is= %8.8x %8.8lx\n" ,flash_read32 (addr), cword.l); retval = (flash_read32 (addr) == cword.l);break ;case FLASH_CFI_64BIT :
@@ -1357,6 +1357,7 @@ int flash_real_protect (flash_info_t * info, long sector, int prot)switch (info->vendor) {case CFI_CMDSET_INTEL_PROG_REGIONS :case CFI_CMDSET_INTEL_STANDARD : +case CFI_CMDSET_INTEL_EXTENDED :flash_write_cmd (info, sector,0 ,FLASH_CMD_CLEAR_STATUS );flash_write_cmd (info, sector,0 ,FLASH_CMD_PROTECT );
Signature · 1 line
1.5.5
PATCH 1/1 Fix regression in drivers/mtd/cfi_flash.c.
Quoted 5 lines · Andrew Klossner
Fix a regression in the 1.3.4 version of
drivers/mtd/cfi_flash.c.Add a case to the new switch statement in
flash_real_protect()to make flash chips using the Intel extended command set work again. Also correct a debug printf format-string/argument mismatch.
The Intel extended command set problem was fixed with another patch just yesterday:
[PATCH] Add CFI_CMDSET_INTEL_EXTENDED to fix flash_real_protect()
From Nick Spence.
It would be great though if you could send another patch to fix the debug printf problem.
Thanks.
Best regards,
Stefan
=====================================================================
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-0 Fax: +49-8142-66989-80 Email: office at denx.de
=====================================================================