Skip to contentSkip to conversation

phylib: phy_mii_ioctl() fixes

PATCH In review Lennert Buytenhek 2 participants 2 messages Sep 18, 2008

Subsystems (3)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 phylib: phy_mii_ioctl() fixes

Make the SIOCGMIIPHY case fall through properly (it is supposed to not only return the ID of the default PHY but also to read from that PHY), and make phy_mii_ioctl() return the same error code as generic_mii_ioctl() in case of an unsupported operation.

drivers/net/phy/phy.c +3 -2
Index: linux-2.6/drivers/net/phy/phy.c
===================================================================
@@ -411,7 +411,8 @@ int phy_mii_ioctl(struct phy_device *phy
 	switch (cmd) {
 	case SIOCGMIIPHY:
 		mii_data->phy_id = phydev->addr;
-		break;
+		/* fall through */
+
 	case SIOCGMIIREG:
 		mii_data->val_out = phy_read(phydev, mii_data->reg_num);
 		break;
@@ -458,7 +459,7 @@ int phy_mii_ioctl(struct phy_device *phy
 		break;
 
 	default:
-		return -ENOTTY;
+		return -EOPNOTSUPP;
 	}
 
 	return 0;