phylib: phy_mii_ioctl() fixes
Subsystems (3)
PATCH 1/1 phylib: phy_mii_ioctl() fixes
Make the SIOCGMIIPHY case fall through properly (it is supposed to not only return the ID of the default PHY but also to read from that PHY), and make phy_mii_ioctl() return the same error code as generic_mii_ioctl() in case of an unsupported operation.
Signed-off-by Lennert Buytenhek <[email protected]>
drivers/net/phy/phy.c +3 -2
@@ -411,7 +411,8 @@ int phy_mii_ioctl(struct phy_device *physwitch (cmd) {case SIOCGMIIPHY : mii_data->phy_id = phydev->addr; -break ; +/* fall through */ +case SIOCGMIIREG : mii_data->val_out =phy_read (phydev, mii_data->reg_num);break ;
@@ -458,7 +459,7 @@ int phy_mii_ioctl(struct phy_device *phybreak ;default : -return -ENOTTY ; +return -EOPNOTSUPP ; }return 0 ;
Quoted 6 lines · Lennert Buytenhek
Make the SIOCGMIIPHY case fall through properly (it is supposed to not only return the ID of the default PHY but also to read from that PHY), and make
phy_mii_ioctl()return the same error code asgeneric_mii_ioctl()in case of an unsupported operation.Signed-off-by Lennert Buytenhek <[email protected]>
Acked-by Andy Fleming <[email protected]>