multipathd: sdc: readsector0 checker reports path is down

DISCUSSION Ray Van Dolson 4 participants 6 messages Jan 8, 2009 2 messages not in the archive Device mapper

lore
Share & tools
lore
#0 lore raw

I'm still getting the hang of iSCSI and multipath, so bear with me if this is a FAQ that I've missed...

I have a host attaching to an MD3000i via iSCSI/dm-multipath that is working but showing a lot of the following errors in syslog:

multipathd: sdc: readsector0 checker reports path is down

My initial impression is that sdc is likely the "passive" path (for failover) whereas sdd is my active path:

  # multipath -ll
  sdc: checker msg is "readsector0 checker reports path is down"
  mpath2 (36001ec9000f338370000000000000000) dm-2 DELL,Universal Xport
  [size=20M][features=0][hwhandler=0]
  \_ round-robin 0 [prio=0][enabled]
   \_ 4:0:0:31 sdf 8:80  [active][ready] 
  mpath1 (36001ec9000f337dd0000000000000000) dm-1 DELL,Universal Xport
  [size=20M][features=0][hwhandler=0]
  \_ round-robin 0 [prio=0][enabled]
   \_ 3:0:0:31 sde 8:64  [active][ready] 
  mpath0 (36001ec9000f337dd0000065b491854a4) dm-0 DELL,MD3000i
  [size=150G][features=0][hwhandler=1 rdac]
  \_ round-robin 0 [prio=3][active]
   \_ 3:0:0:0  sdd 8:48  [active][ready] 
  \_ round-robin 0 [prio=0][enabled]
   \_ 4:0:0:0  sdc 8:32  [failed][faulty]
  # iscsiadm -m discovery -t sendtargets -p 192.168.132.101:3260
  0.0.0.0:3260,1 iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
  0.0.0.0:3260,2 iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
  192.168.132.101:3260,1 iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
  192.168.132.102:3260,2 iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
  # iscsiadm -m session -P 1
  Target: iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
    Current Portal: 192.168.132.101:3260,1
    Persistent Portal: 192.168.132.101:3260,1
      **********
      Interface:
      **********
      Iface Name: default
      Iface Transport: tcp
      Iface Initiatorname: iqn.1994-05.com.redhat:2738e0d3bd21
      Iface IPaddress: 192.168.132.202
      Iface HWaddress: default
      Iface Netdev: default
      SID: 1
      iSCSI Connection State: LOGGED IN
      iSCSI Session State: Unknown
      Internal iscsid Session State: NO CHANGE
    Current Portal: 192.168.132.102:3260,2
    Persistent Portal: 192.168.132.102:3260,2
      **********
      Interface:
      **********
      Iface Name: default
      Iface Transport: tcp
      Iface Initiatorname: iqn.1994-05.com.redhat:2738e0d3bd21
      Iface IPaddress: 192.168.132.202
      Iface HWaddress: default
      Iface Netdev: default
      SID: 2
      iSCSI Connection State: LOGGED IN
      iSCSI Session State: Unknown
      Internal iscsid Session State: NO CHANGE

sde and sdf are the silly 20MB partition that the MD3000 creates and I'm not using either.

My ultimate goal is to not have so many of the path is down errors showing up in my syslog file (hundreds and hundreds of them). I'm not sure if their presence is normal (indicative of a passive path) or indicative of a problem.

Also, I'm not clear as to how I should identify which target corresponds with which drive (sdc or sdd).

Any thoughts? I don't have direct access to the MD3000i unfortunately... this is from a CentOS 5.2 system btw.

Ray

A message that is not in the archive (sent off-list or not yet received): [email protected]

#2 lore raw
Quoted 7 lines · Ray Van Dolson

I'm still getting the hang of iSCSI and multipath, so bear with me if this is a FAQ that I've missed...

I have a host attaching to an MD3000i via iSCSI/dm-multipath that is working but showing a lot of the following errors in syslog:

multipathd: sdc: readsector0 checker reports path is down

You are using the wrong path checker, wrong path priority program, and no hardware path checker :-(

Here is what you need in your multipath.conf file:

#
# DELL :D3000i :: Active-Passive RDAC
# Note: The same as the IBM DS3300
#
device {
vendor "DELL"
product "MD3000i"
product_blacklist "Universal Xport"
features "1 queue_if_no_path"
path_grouping_policy group_by_prio
hardware_handler "1 rdac"
path_checker rdac
prio "rdac"
failback immediate
}

Thought you might need to replace the 'prio "rdac"' with
'prio_callout "/sbin/mpath_prio_rdac" as I think RHEL5/CentOS5 uses
the old calling convention.

This should get rid of your down errors and show your passive/active path properly.

#3 lore raw
Quoted 32 lines · Konrad Rzeszutek
Quoted 7 lines · Ray Van Dolson

I'm still getting the hang of iSCSI and multipath, so bear with me if this is a FAQ that I've missed...

I have a host attaching to an MD3000i via iSCSI/dm-multipath that is working but showing a lot of the following errors in syslog:

multipathd: sdc: readsector0 checker reports path is down

You are using the wrong path checker, wrong path priority program, and no hardware path checker :-(

Here is what you need in your multipath.conf file:

#
# DELL :D3000i :: Active-Passive RDAC
# Note: The same as the IBM DS3300
#
device {
vendor "DELL"
product "MD3000i"
product_blacklist "Universal Xport"
features "1 queue_if_no_path"
path_grouping_policy group_by_prio
hardware_handler "1 rdac"
path_checker rdac
prio "rdac"
failback immediate
}

Quoted 6 lines

Thought you might need to replace the 'prio "rdac"' with
'prio_callout "/sbin/mpath_prio_rdac" as I think RHEL5/CentOS5 uses
the old calling convention.

This should get rid of your down errors and show your passive/active path properly.

Thanks. I had to remove the features line -- got an Unrecognised feature request error otherwise.

Thanks again,
Ray

#4 lore raw
In reply to Ray Van Dolson
Quoted 7 lines · Ray Van Dolson

I'm still getting the hang of iSCSI and multipath, so bear with me if this is a FAQ that I've missed...

I have a host attaching to an MD3000i via iSCSI/dm-multipath that is working but showing a lot of the following errors in syslog:

multipathd: sdc: readsector0 checker reports path is down

you should be using the rdac path checker. In addition to that you should be using rdac hardware handler and tpc priority checker.

If you have and entry for your MD3000i in /etc/multipath.conf, replace it with this. If not add this
-------------------
devices {
device {
vendor "DELL"
product "MD3000i"
hardware_handler "1 rdac"
path_checker rdac
failback immediate
path_grouping_policy group_by_prio
no_path_retry queue
prio_callout "/sbin/mpath_prio_tpc /dev/%n"
}
}
---------------------

After this change you have to do:
- multipath -F
- service multipathd restart

Let me know how it goes.

Quoted 3 lines

My initial impression is that sdc is likely the "passive" path (for failover) whereas sdd is my active path:

yes.

Quoted 80 lines
  # multipath -ll
  sdc: checker msg is "readsector0 checker reports path is down"
  mpath2 (36001ec9000f338370000000000000000) dm-2 DELL,Universal Xport
  [size=20M][features=0][hwhandler=0]
  \_ round-robin 0 [prio=0][enabled]
   \_ 4:0:0:31 sdf 8:80  [active][ready] 
  mpath1 (36001ec9000f337dd0000000000000000) dm-1 DELL,Universal Xport
  [size=20M][features=0][hwhandler=0]
  \_ round-robin 0 [prio=0][enabled]
   \_ 3:0:0:31 sde 8:64  [active][ready] 
  mpath0 (36001ec9000f337dd0000065b491854a4) dm-0 DELL,MD3000i
  [size=150G][features=0][hwhandler=1 rdac]
  \_ round-robin 0 [prio=3][active]
   \_ 3:0:0:0  sdd 8:48  [active][ready] 
  \_ round-robin 0 [prio=0][enabled]
   \_ 4:0:0:0  sdc 8:32  [failed][faulty]
  # iscsiadm -m discovery -t sendtargets -p 192.168.132.101:3260
  0.0.0.0:3260,1 iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
  0.0.0.0:3260,2 iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
  192.168.132.101:3260,1 iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
  192.168.132.102:3260,2 iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
  # iscsiadm -m session -P 1
  Target: iqn.1984-05.com.dell:powervault.6001ec9000f337dd0000000048bdc862
    Current Portal: 192.168.132.101:3260,1
    Persistent Portal: 192.168.132.101:3260,1
      **********
      Interface:
      **********
      Iface Name: default
      Iface Transport: tcp
      Iface Initiatorname: iqn.1994-05.com.redhat:2738e0d3bd21
      Iface IPaddress: 192.168.132.202
      Iface HWaddress: default
      Iface Netdev: default
      SID: 1
      iSCSI Connection State: LOGGED IN
      iSCSI Session State: Unknown
      Internal iscsid Session State: NO CHANGE
    Current Portal: 192.168.132.102:3260,2
    Persistent Portal: 192.168.132.102:3260,2
      **********
      Interface:
      **********
      Iface Name: default
      Iface Transport: tcp
      Iface Initiatorname: iqn.1994-05.com.redhat:2738e0d3bd21
      Iface IPaddress: 192.168.132.202
      Iface HWaddress: default
      Iface Netdev: default
      SID: 2
      iSCSI Connection State: LOGGED IN
      iSCSI Session State: Unknown
      Internal iscsid Session State: NO CHANGE

sde and sdf are the silly 20MB partition that the MD3000 creates and I'm not using either.

My ultimate goal is to not have so many of the path is down errors showing up in my syslog file (hundreds and hundreds of them). I'm not sure if their presence is normal (indicative of a passive path) or indicative of a problem.

Also, I'm not clear as to how I should identify which target corresponds with which drive (sdc or sdd).

Any thoughts? I don't have direct access to the MD3000i unfortunately... this is from a CentOS 5.2 system btw.

Ray

--~--~---------~--~----~------------~-------~--~----~
You received this message because you are subscribed to the Google Groups "open-iscsi" group. To post to this group, send email to [email protected]
To unsubscribe from this group, send email to [email protected] For more options, visit this group at http://groups.google.com/group/open-iscsi
-~----------~----~----~----~------~----~------~--~---

#5 lore raw
Quoted 30 lines · Chandra Seetharaman
Quoted 7 lines · Ray Van Dolson

I'm still getting the hang of iSCSI and multipath, so bear with me if this is a FAQ that I've missed...

I have a host attaching to an MD3000i via iSCSI/dm-multipath that is working but showing a lot of the following errors in syslog:

multipathd: sdc: readsector0 checker reports path is down

you should be using the rdac path checker. In addition to that you should be using rdac hardware handler and tpc priority checker.

If you have and entry for your MD3000i in /etc/multipath.conf, replace it with this. If not add this
-------------------
devices {
device {
vendor "DELL"
product "MD3000i"
hardware_handler "1 rdac"
path_checker rdac
failback immediate
path_grouping_policy group_by_prio
no_path_retry queue
prio_callout "/sbin/mpath_prio_tpc /dev/%n"
}
}
---------------------

Quoted 5 lines

After this change you have to do:
- multipath -F
- service multipathd restart

Let me know how it goes.

This appears to have done the trick. So, I guess the default path checker is readsector0 and rdac is another method -- I imagine it directly talks to my MD3000i to determine path status?

Quoted 5 lines
Quoted 3 lines

My initial impression is that sdc is likely the "passive" path (for failover) whereas sdd is my active path:

yes.

Thanks much!

Ray

A message that is not in the archive (sent off-list or not yet received): [email protected]

#7 lore raw
Quoted 35 lines · Ray Van Dolson
Quoted 34 lines · Chandra Seetharaman
Quoted 7 lines · Ray Van Dolson

I'm still getting the hang of iSCSI and multipath, so bear with me if this is a FAQ that I've missed...

I have a host attaching to an MD3000i via iSCSI/dm-multipath that is working but showing a lot of the following errors in syslog:

multipathd: sdc: readsector0 checker reports path is down

you should be using the rdac path checker. In addition to that you should be using rdac hardware handler and tpc priority checker.

If you have and entry for your MD3000i in /etc/multipath.conf, replace it with this. If not add this
-------------------
devices {
device {
vendor "DELL"
product "MD3000i"
hardware_handler "1 rdac"
path_checker rdac
failback immediate
path_grouping_policy group_by_prio
no_path_retry queue
prio_callout "/sbin/mpath_prio_tpc /dev/%n"
}
}
---------------------

After this change you have to do:
- multipath -F
- service multipathd restart

Quoted 5 lines
Quoted 1 line

Let me know how it goes.

This appears to have done the trick. So, I guess the default path checker is readsector0 and rdac is another method -- I imagine it directly talks to my MD3000i to determine path status?

Yes, it sends a C9 inquiry to the storage controller and determines the state.

Quoted 15 lines
Quoted 6 lines
Quoted 4 lines

My initial impression is that sdc is likely the "passive" path (for failover) whereas sdd is my active path:

yes.

Thanks much!

Ray

--
dm-devel mailing list
[email protected]