I need to ask few questions, thats maybe better to ask somewhere like IRC. But mail is ok, if i can get answers...

Because i am not understanding well, how HTB works.
For example iproute2 over netlink sending various parameters. For me interesting now burst/cburst since they are seems incorrect.

It is some "tokens" that used to refill bucket each piece of time (related with get_hz and rate?)
Is there any place i can read about this?

#2 lore raw

PATCH 1/1 iproute2 : invalid burst/cburst calculation with hrtimers

Quoted 7 lines · On Thursday 22 January 2009 09:25:41 Jarek Poplawski wrote:

On 21-01-2009 15:33, Denys Fedoryschenko wrote:
...

Quoted 3 lines

It is some "tokens" that used to refill bucket each piece of time (related with get_hz and rate?)
Is there any place i can read about this?

Quoted 7 lines

http://en.wikipedia.org/wiki/Token_bucket

Jarek P.
--
To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html

Thanks a lot. Seems also Martin Devera pointed me, what can be issue. HZ=1000000000 is way too high.
Real tests shows, that HZ=1000 more than enough with hrtimers on.

By the way possible it is triggered deadlock bug in htb, it is not a fix of this bug, but a fix of very wrong behaviour, because of this bug
HTB will use very extensively resources.

If it's required, i can give more detailed explanation

------------->
iproute2 : invalid burst/cburst calculation with hrtimers

If hrtimers on, /proc/net/psched shows 4th variable
as 1000000000
Because burst calculated by division rate to this variable, it will be almost always zero. As result, we will get higher system load on low rates, and on high rates shaper will not able to process data. It is checked and proved. Core 2 Quad was not able to shape 200Mbps, and gave only 180-190. It is more safe to set it to 1000HZ. If user wants, he can set custom "env" HZ variable.

---

tc/q_htb.c +11 -3
diff -Naur iproute2/tc/q_htb.c iproute2-new/tc/q_htb.c
@@ -110,6 +110,7 @@
 	unsigned mtu;
 	unsigned short mpu = 0;
 	unsigned short overhead = 0;
+	unsigned int bursthz;
 	unsigned int linklayer  = LINKLAYER_ETHERNET; /* Assume ethernet */
 	struct rtattr *tail;
 
@@ -209,9 +210,16 @@
 	if (!opt.ceil.rate) opt.ceil = opt.rate;
 
 	/* compute minimal allowed burst from rate; mtu is added here to make
-	   sute that buffer is larger than mtu and to have some safeguard space */
-	if (!buffer) buffer = opt.rate.rate / get_hz() + mtu;
-	if (!cbuffer) cbuffer = opt.ceil.rate / get_hz() + mtu;
+	   sure that buffer is larger than mtu and to have some safeguard space 
+	   With hrtimers enabled, hz variable gets too high resolution. If we
+	   use it for computing burst, burst will be too low. In worst case 
+	   we will not reach specified rate/ceil, in best - load will be too 
+	   high.
+	*/
+	bursthz = get_hz() == 1000000000 ? 1000 : get_hz();	
+
+	if (!buffer) buffer = opt.rate.rate / bursthz + mtu;
+	if (!cbuffer) cbuffer = opt.ceil.rate / bursthz + mtu;
 
 	opt.ceil.overhead = overhead;
 	opt.rate.overhead = overhead;