acerhdf: Return temperature in milidegree

PATCH In review Peter Feuerer 4 participants 9 messages Oct 19, 2009 – Nov 2, 2009

Subsystems (2)
lore
Share & tools
lore

Peter Feuerer

author maintainer
#0 lore raw

PATCH 1/1 acerhdf: Return temperature in milidegree

Hi Boris,

what do you think about this patch?

regards,
--peter

--

Return temperature in milidegree instead of degree, as userspace applications expect the temperature in milidegree.

Cc Borislav Petkov <[email protected]>
Cc Andreas Mohr <[email protected]>
---
 drivers/platform/x86/acerhdf.c |   12 ++++++------
 1 files changed, 6 insertions(+), 6 deletions(-)
drivers/platform/x86/acerhdf.c +6 -6
index b713c6e..a588f96 100644
@@ -52,7 +52,7 @@
  */
 #undef START_IN_KERNEL_MODE
 
-#define DRV_VER "0.5.17"
+#define DRV_VER "0.5.18"
 
 /*
  * According to the Atom N270 datasheet,
@@ -61,7 +61,7 @@
  * measured by the on-die thermal monitor are within 0 <= Tj <= 90. So,
  * assume 89°C is critical temperature.
  */
-#define ACERHDF_TEMP_CRIT 89
+#define ACERHDF_TEMP_CRIT 89000
 #define ACERHDF_FAN_OFF 0
 #define ACERHDF_FAN_AUTO 1
 
@@ -69,7 +69,7 @@
  * No matter what value the user puts into the fanon variable, turn on the fan
  * at 80 degree Celsius to prevent hardware damage
  */
-#define ACERHDF_MAX_FANON 80
+#define ACERHDF_MAX_FANON 80000
 
 /*
  * Maximum interval between two temperature checks is 15 seconds, as the die
@@ -85,8 +85,8 @@ static int kernelmode;
 #endif
 
 static unsigned int interval = 10;
-static unsigned int fanon = 63;
-static unsigned int fanoff = 58;
+static unsigned int fanon = 63000;
+static unsigned int fanoff = 58000;
 static unsigned int verbose;
 static unsigned int fanstate = ACERHDF_FAN_AUTO;
 static char force_bios[16];
@@ -171,7 +171,7 @@ static int acerhdf_get_temp(int *temp)
 	if (ec_read(bios_cfg->tempreg, &read_temp))
 		return -EINVAL;
 
-	*temp = read_temp;
+	*temp = read_temp * 1000;
 
 	return 0;
 }
Signature · 1 line
1.6.4.4
#1 lore raw

Hi,

Quoted 4 lines · Peter Feuerer

Hi Boris,

what do you think about this patch?

Personally I'm hurting a bit due to the open-coded "* 1000" transition in all places.

I'd add a helper macro
#define TEMP_DEGREE_TO_SYS(x) ((x) * 1000)
and use that in all places where it matters.

Advantage:
- either no mistyping (10000 instead of 1000) _or_ bug occurring in _all_ places where this macro is used
- easily grepped-for
- easily changed once the system granularity gets updated

Andreas Mohr

author maintainer
#2 lore raw

Hi Andreas,

thank you very much for your brainstorming.

Quoted 15 lines · Andreas Mohr

Hi,

Quoted 4 lines · Peter Feuerer

Hi Boris,

what do you think about this patch?

Personally I'm hurting a bit due to the open-coded "* 1000" transition in all places.

I'd add a helper macro
#define TEMP_DEGREE_TO_SYS(x) ((x) * 1000)
and use that in all places where it matters.

Quoted 5 lines

Advantage:
- either no mistyping (10000 instead of 1000) _or_ bug occurring in _all_ places where this macro is used
- easily grepped-for
- easily changed once the system granularity gets updated

I agree with you in these points, but I have also some disadvantages to discuss:

Disadvantages:
- Thinking about the implemenation such a macro would require, users may get confused. They would still set the fanon / fanoff trip points in degree, but when they read documentation or the current temperature, millidegree is used.
- I think "TEMP_DEGREE_TO_SYS(59)" in code is not
as good readable as "59000"

what about writing something like "59 * 1000" insead of "59000"?

Or something like that:

#define FACTOR_MILLIDEGREE 1000
59 * FACTOR_MILLIDEGREE

this solution has all your listed advantages and eliminates the disadvantages I see in the "TEMP_DEGREE_TO_SYS" solution.

--peter

#3 lore raw

Hi,

Quoted 11 lines · Peter Feuerer

I agree with you in these points, but I have also some disadvantages to discuss:

Disadvantages:
- Thinking about the implemenation such a macro would require, users may get confused. They would still set the fanon / fanoff trip points in
degree, but when they read documentation or the current temperature, millidegree is used. - I think "TEMP_DEGREE_TO_SYS(59)" in code is not as good readable as "59000"

what about writing something like "59 * 1000" insead of "59000"?

Quoted 7 lines

Or something like that:

#define FACTOR_MILLIDEGREE 1000
59 * FACTOR_MILLIDEGREE

this solution has all your listed advantages and eliminates the disadvantages I see in the "TEMP_DEGREE_TO_SYS" solution.

Well, yes, much better, in fact TEMP_DEGREE_TO_SYS is simple overengineering (using a generic, _cryptic_ name in order to keep using it in the somewhat unlikely case of having the factor change when you could just as well have mass-renamed the couple places that use the macro name)

Andreas

#4 lore raw
In reply to Peter Feuerer

Hi,

Quoted 1 line · Peter Feuerer

what do you think about this patch?

I don't think it is worth the trouble. Just compare the changes your patch introduces with a simple

temp * 1000

you can do in userspace.

If this were a standard interface then maybe the changes could be warranted but it doesn't seem like so...

Signature · 2 lines
Regards/Gruss,
Boris
author maintainer
#5 lore raw

Hi Boris,

Quoted 8 lines · Borislav Petkov

Hi,

Quoted 1 line · Peter Feuerer

what do you think about this patch?

I don't think it is worth the trouble. Just compare the changes your patch introduces with a simple

Quoted 7 lines

temp * 1000

you can do in userspace.

If this were a standard interface then maybe the changes could be warranted but it doesn't seem like so...

I just had a look at the documentation concerning this topic:

Documentation/thermal/sysfs-api.txt:162

temp Current temperature as reported by thermal zone (sensor)
Unit: millidegree Celsius
RO
Required

It is expected to be in millidegree, so I think we should discuss, modify and apply the patch.

regards,
--peter

#6 lore raw
Quoted 4 lines · Peter Feuerer

I just had a look at the documentation concerning this topic:

Documentation/thermal/sysfs-api.txt:162

Quoted 8 lines

temp Current temperature as reported by thermal zone (sensor)
Unit: millidegree Celsius
RO
Required

It is expected to be in millidegree, so I think we should discuss, modify and apply the patch.

Well well, looka here, it is an interface! I guess the temperature has to be in millidegrees for better granularity or similar. Now userspace has to do temp / 1000.0 and so on.

In that case, the patch should be applied. I'll give it a run later.

Minor nitpick: Add the sysfs-api requirement to the commit message instead of "userspace applications."

Thanks.

Signature · 2 lines
Regards/Gruss,
    Boris.
#7 lore raw

Hi Boris,

Quoted 11 lines · Borislav Petkov
Quoted 10 lines · Peter Feuerer

I just had a look at the documentation concerning this topic:

Documentation/thermal/sysfs-api.txt:162

temp Current temperature as reported by thermal zone (sensor)
Unit: millidegree Celsius
RO
Required

Quoted 6 lines
Quoted 2 lines

It is expected to be in millidegree, so I think we should discuss, modify and apply the patch.

Well well, looka here, it is an interface! I guess the temperature has to be in millidegrees for better granularity or similar. Now userspace has to do temp / 1000.0 and so on.

This is what the userspace applications like thermal-plugin of xfce-panel do.

Quoted 2 lines

In that case, the patch should be applied. I'll give it a run later.

Did you already give it a try?

Quoted 3 lines

Minor nitpick: Add the sysfs-api requirement to the commit message instead of "userspace applications."

will change this, when submitting the patch to Andrew.

kind regards,
--peter