ppc4xx: Initialize magnetic coupler on VOM405 boards
PATCH 1/1 ppc4xx: Initialize magnetic coupler on VOM405 boards
This patch fixes an ugly behavior of the IL712 magnetic coupler as used on VOM405. These parts will remember their last state over a power cycle which might cause unwanted behavior.
--- board/esd/vom405/vom405.c | 35 +++++++++++++++++++++++++++++++++++ 1 files changed, 35 insertions(+), 0 deletions(-)
board/esd/vom405/vom405.c +35 -0
@@ -26,11 +26,40 @@#include <asm/io.h> #include <command.h> #include <malloc.h> +#include <sja1000.h> DECLARE_GLOBAL_DATA_PTR ;extern void lxt971_no_sleep (void ); +/* +* generate a short spike on the CAN tx line +* to bring the couplers in sync +*/ +void init_coupler (u32 addr) +{ +struct sja1000_basic_s *ctrl = (struct sja1000_basic_s *)addr; + +/* reset */ +out_8 (&ctrl->cr,CR_RR ); + +/* dominant */ +out_8 (&ctrl->btr0,0x00 );/* btr setup is required */ +out_8 (&ctrl->btr1,0x14 );/* we use 1Mbit/s */ +out_8 (&ctrl->oc,OC_TP1 |OC_TN1 |OC_POL1 | +OC_TP0 |OC_TN0 |OC_POL0 |OC_MODE1 ); +out_8 (&ctrl->cr,0x00 ); + +/* delay */ +in_8 (&ctrl->cr); +in_8 (&ctrl->cr); +in_8 (&ctrl->cr); +in_8 (&ctrl->cr); + +/* reset */ +out_8 (&ctrl->cr,CR_RR ); +} +int board_early_init_f (void ) {/*
@@ -77,6 +106,12 @@ int misc_init_r (void) gd->bd->bi_flashstart =0 - gd->bd->bi_flashsize; gd->bd->bi_flashoffset =0 ; +/* +* Init magnetic coupler +*/ +if (!getenv ("noinitcoupler" )) +init_coupler (CAN_BA ); +return (0 ); }
Signature · 1 line
1.6.1
PATCH 1/1 ppc4xx: Initialize magnetic coupler on VOM405 boards
Quoted 3 lines · On Tuesday 27 October 2009 19:58:09 Matthias Fuchs wrote:
This patch fixes an ugly behavior of the IL712 magnetic coupler as used on VOM405. These parts will remember their last state over a power cycle which might cause unwanted behavior.
Applied to u-boot-ppc4xx/master. Thanks.
Cheers,
Stefan
--
DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-0 Fax: (+49)-8142-66989-80 Email: office at denx.de