PATCH 1/1 e1000e: do not initiate autonegotiation during OEM configuration

From: Bruce Allan <[email protected]>

When configuring the OEM bits in the PHY on 82577/82578, do not restart autonegotiation if the firmware is blocking it (e.g. when an IDE-R session is active) because the link must not go down.

---

 drivers/net/e1000e/ich8lan.c |    3 ++-
 1 files changed, 2 insertions(+), 1 deletions(-)
drivers/net/e1000e/ich8lan.c +2 -1
index 92cf103..eff3f47 100644
@@ -1118,7 +1118,8 @@ static s32 e1000_oem_bits_config_ich8lan(struct e1000_hw *hw, bool d0_state)
 			oem_reg |= HV_OEM_BITS_LPLU;
 	}
 	/* Restart auto-neg to activate the bits */
-	oem_reg |= HV_OEM_BITS_RESTART_AN;
+	if (!e1000_check_reset_block(hw))
+		oem_reg |= HV_OEM_BITS_RESTART_AN;
 	ret_val = hw->phy.ops.write_phy_reg_locked(hw, HV_OEM_BITS, oem_reg);
 