LVM2 ./WHATS_NEW lib/metadata/mirror.c test/t- ...
CVSROOT: /cvs/lvm2
Module name: LVM2
Changes by: jbrassow at sourceware.org 2010-04-21 13:55:08
Modified files:
. : WHATS_NEW lib/metadata : mirror.c test : t-lvconvert-mirror.sh t-mirror-lvconvert.sh
Log message:
Disallow the primary mirror image from being removed when the mirror is not in-sync. This restriction is not extended to repair operations (i.e. it will not limit what 'lvconvert --repair' can do).
Patches:
http://sourceware.org/cgi-bin/cvsweb.cgi/LVM2/WHATS_NEW.diff?cvsroot=lvm2&r1=1.1532&r2=1.1533
http://sourceware.org/cgi-bin/cvsweb.cgi/LVM2/lib/metadata/mirror.c.diff?cvsroot=lvm2&r1=1.113&r2=1.114
http://sourceware.org/cgi-bin/cvsweb.cgi/LVM2/test/t-lvconvert-mirror.sh.diff?cvsroot=lvm2&r1=1.2&r2=1.3
http://sourceware.org/cgi-bin/cvsweb.cgi/LVM2/test/t-mirror-lvconvert.sh.diff?cvsroot=lvm2&r1=1.23&r2=1.24
WHATS_NEW +1 -0
@@ -1,5 +1,6 @@ Version 2.02.64 - ================================= + Disallow primary mirror image removal when mirror is not in-sync. Remove obsolete --name parameter from vgcfgrestore. Add -S command to clvmd to restart the daemon preserving exclusive locks. Increment lvm2app version from 1 to 2.
lib/metadata/mirror.c +14 -4
@@ -751,7 +751,7 @@ uint32_t *removed) {uint32_t m; -uint32_t s; +int32_t s;int removable_pvs_specified;struct logical_volume *sub_lv;struct logical_volume *detached_log_lv =NULL ;
@@ -781,15 +781,25 @@/* Move removable_pvs to end of array */ if (removable_pvs_specified) { -for (s =0 ; s < mirrored_seg->area_count && - old_area_count - new_area_count < num_removed; s++) { +for (s = mirrored_seg->area_count -1 ; + s >=0 && old_area_count - new_area_count < num_removed; + s--) { sub_lv =seg_lv (mirrored_seg, s);if (!is_temporary_mirror_layer (sub_lv) &&_is_mirror_image_removable (sub_lv, removable_pvs)) { +/* +* Check if the user is trying to pull the +* primary mirror image when the mirror is +* not in-sync. +*/ +if ((s ==0 ) && !_mirrored_lv_in_sync (lv) && + !(lv->status &PARTIAL_LV )) { +log_error ("Unable to remove primary mirror image while mirror is not in-sync" ); + return_0; + }if (!shift_mirror_images (mirrored_seg, s)) return_0; - s--;/* adjust counter after shifting */ new_area_count--; } }
test/t-lvconvert-mirror.sh +12 -2
@@ -61,10 +61,20 @@ not lvconvert -m+1 --mirrorlog core $vg/$lv1 $dev1 lvremove -ff $vg -lvcreate -l2 -m2 -n $lv1 $vg $dev1 $dev2 $dev4 $dev3:0-1 +# Start w/ 3-way mirror +# Test pulling primary image before mirror in-sync (should fail) +# Test pulling primary image after mirror in-sync (should work) +# Test that the correct devices remain in the mirror +lvcreate -l8 -m2 -n $lv1 $vg $dev1 $dev2 $dev4 $dev3:0-1 +# FIXME: +# This is somewhat timing dependent - sync /could/ finish before +# we get a chance to have this command fail +not lvconvert -m-1 $vg/$lv1 $dev1 +while [ `lvs --noheadings -o copy_percent $vg/$lv1` != "100.00" ]; do + sleep 1 +done lvconvert -m-1 $vg/$lv1 $dev1 check mirror_images_on $lv1 $dev2 $dev4 lvconvert -m-1 $vg/$lv1 $dev2 check linear $vg $lv1 check lv_on $vg/$lv1 $dev4 -
test/t-mirror-lvconvert.sh +7 -0
@@ -98,6 +98,12 @@ while (lvs --noheadings -oattr "$lv" | grep -q '^ *c'); do sleep 1; done } +wait_sync_() +{ + local lv=$1 + while [ `lvs --noheadings -o copy_percent $lv` != "100.00" ]; do sleep 1; done +} + check_no_tmplvs_() { local lv=$1
@@ -404,6 +410,7 @@ lvs -a -o+devices $vg check_mirror_count_ $vg/$lv1 2 check_mirror_log_ $vg/$lv1 +wait_sync_ $vg/$lv1 # cannot pull primary unless mirror in-sync lvconvert -m0 $vg/$lv1 $dev1 lvs -a -o+devices $vg check_no_tmplvs_ $vg/$lv1