Hello,

when writing an alsa driver, in the info callback of the control I can specify which range of values this control does accept (uinfo->value.integer.min and .max). If I put 1 as minimum and 10 as maximum for example, I would expect that the default value of this control is something in between the range, e.g. 1, after the driver is loaded.

But I figured out, that ALSA initializes the control with a value of 0, which is not in between the range.

Can someone please tell me why ALSA initializes the Control with a value of zero, even if the minimum in the info callback is 1 ?

Is there any way to initialize the control with some "default" values, aside of snd_ctl_add()?

Best regards and thanks for your help!
Max

Signature · 2 lines
"Feel free" - 10 GB Mailbox, 100 FreeSMS/Monat ...
Jetzt GMX TopMail testen: http://www.gmx.net/de/go/topmail
#1 lore raw
Quoted 3 lines · Max Klein

Can someone please tell me why ALSA initializes the Control with a value of zero, even if the minimum in the info callback is 1 ?

Is there any way to initialize the control with some "default" values, aside of snd_ctl_add()?

What is the problem here? The driver is responsible for the default values - where do you believe that ALSA is overwriting the values you're looking for?

A message that is not in the archive (sent off-list or not yet received): [email protected]

#3 lore raw
Quoted 3 lines · Max Klein

thanks for fast reply, may you tell me how the driver can set the defaults?

EDIT: whoops, I guess it was an error in reasoning from myself...as I have the control of all those variables outputted by the get and put callbacks, I just have to initialize those variables before initializing the control interface, right?

Yes, the driver just needs to make sure that whatever it uses to return the current setting when queried is going to give the right answer from the time the control is set up, normally by initialising variables though if you're doing things like read data back from hardware then you may be able to rely on the hardware defaults.

[Re-adding CC to alsa-devel - it's normal to do a reply to all for Linux lists.]