hpt366: fix clock turnaround
PATCH 2/2 hpt366: fix clock turnaround
DPLL clock (0x21) should be used for writes and PCI clock (0x23) for reads, not vice versa.
Signed-off-by Sergei Shtylyov <[email protected]>
---
The patch is atop of ide-2.6.git tree.
Not sure why I didn't fix this back in 2007... well, nobody has ever complained. :-)
drivers/ide/hpt366.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
drivers/ide/hpt366.c +1 -1
@@ -838,7 +838,7 @@ static void hpt3xxn_set_clock(ide_hwif_tstatic void hpt3xxn_rw_disk (ide_drive_t *drive,struct request *rq) { -hpt3xxn_set_clock (drive->hwif,rq_data_dir (rq) ?0x23 :0x21 ); +hpt3xxn_set_clock (drive->hwif,rq_data_dir (rq) ?0x21 :0x23 ); }/**
From: Sergei Shtylyov <[email protected]>
Date: Mon, 27 Sep 2010 18:09:43 +0400
Quoted 4 lines
DPLL clock (
0x21) should be used for writes and PCI clock (0x23) for reads, not vice versa.Signed-off-by Sergei Shtylyov <[email protected]>
Also applied, thanks.