Skip to contentSkip to conversation

e1000e: Fix for offline diag test failure at first call

PATCH Applied Jeff Kirsher 2 participants 2 messages Oct 16, 2010 – Oct 18, 2010

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 e1000e: Fix for offline diag test failure at first call

From: Carolyn Wyborny <[email protected]>

Move link test call to later in the offline sequence, move the restore settings block to afterwards and add another reset to ensure the hardware is in a known state afterwards.

---

 drivers/net/e1000e/ethtool.c |   19 ++++++++-----------
 1 files changed, 8 insertions(+), 11 deletions(-)
drivers/net/e1000e/ethtool.c +8 -11
index b7f15b3..8984d16 100644
@@ -1717,13 +1717,6 @@ static void e1000_diag_test(struct net_device *netdev,
 
 		e_info("offline testing starting\n");
 
-		/*
-		 * Link test performed before hardware reset so autoneg doesn't
-		 * interfere with test result
-		 */
-		if (e1000_link_test(adapter, &data[4]))
-			eth_test->flags |= ETH_TEST_FL_FAILED;
-
 		if (if_running)
 			/* indicate we're in test mode */
 			dev_close(netdev);
@@ -1747,15 +1740,19 @@ static void e1000_diag_test(struct net_device *netdev,
 		if (e1000_loopback_test(adapter, &data[3]))
 			eth_test->flags |= ETH_TEST_FL_FAILED;
 
+		/* force this routine to wait until autoneg complete/timeout */
+		adapter->hw.phy.autoneg_wait_to_complete = 1;
+		e1000e_reset(adapter);
+		adapter->hw.phy.autoneg_wait_to_complete = 0;
+
+		if (e1000_link_test(adapter, &data[4]))
+			eth_test->flags |= ETH_TEST_FL_FAILED;
+
 		/* restore speed, duplex, autoneg settings */
 		adapter->hw.phy.autoneg_advertised = autoneg_advertised;
 		adapter->hw.mac.forced_speed_duplex = forced_speed_duplex;
 		adapter->hw.mac.autoneg = autoneg;
-
-		/* force this routine to wait until autoneg complete/timeout */
-		adapter->hw.phy.autoneg_wait_to_complete = 1;
 		e1000e_reset(adapter);
-		adapter->hw.phy.autoneg_wait_to_complete = 0;
 
 		clear_bit(__E1000_TESTING, &adapter->state);
 		if (if_running)
maintainer Applied
#1 lore raw

From: Jeff Kirsher <[email protected]>
Date: Fri, 15 Oct 2010 20:35:31 -0700

Quoted 10 lines

From: Carolyn Wyborny <[email protected]>

Move link test call to later in the offline sequence, move the restore settings block to afterwards and add another reset to ensure the hardware is in a known state afterwards.

Applied.