mpt2sas : WarpDrive New product SSS6200 support added
PATCH 1/1 mpt2sas : WarpDrive New product SSS6200 support added
Introduction
This patch has
Support for the new solid state device product SSS6200 from LSI and relavent features w.r.t SSS6200.
The major feature added in this driver is supporting Direct-I/O to the SSS6200 storage.There are some additional changes done to avoid exposing the RAID member disks to the OS and hiding/exposing drives based on the OEM Specific Flag in Manufacturing Page10 (this is required to handle specific changes in the SSS6200 firmware).
Each and every changes are listed below.
1. Hiding IR related messages.
For SSS6200, the driver is modified not to print IR related events. Even if the debugging is enabled the IR related messages will not be displayed. In some places if there is a need to display a message related to IR the string "IR" is replaced with string "DD" and the string "volume" is replaced with "direct drive". But the function names are not changed hence there are some places where the reference to volume can be seen if debug level is set.
2. Removed RAID transport support
In Linux the user can retrieve RAID volume information from the sysfs directory. This support is removed for SSS6200.
3. Direct I/O support.
The driver tries to enable direct I/O when a volume is reported to the driver by the firmware through IRCC events and the driver does this just before reporting to the OS, hence all the OS issued I/O can go through direct path if they can, The first validation is to see whether the manufacturing page10 flag is set to expose all drives always. If that is set, the driver will not enable direct I/O and displays the message "DDIO" is disabled globally as drives are exposed. The driver checks whether there is more than one volume in the controller, if so the direct I/O will be disabled globally for all volumes in the controller and the message displayed will be "DDIO is disabled globally as number of drives > 1.
If retrieving number of PD is failed the driver will not enable direct I/O and displays the message Failure in computing number of drives DDIO disabled. If memory allocation for RAIDVolumePage0 is failed, the driver will not enable direct I/O and displays the message Memory allocation failure for RVPG0 DDIO disabled. If retrieving RAIDVolumePage0 is failed the driver will not enable direct I/O and displays the message Failure in retrieving RVPG0 DDIO disabled
If the number of PD in a volume is greater than 8, then the direct I/O will be disabled.
If any of individual drives handle retrieval is failed then the DD-IO will be disabled.
If the volume is not RAID0 or if the block size is not 512 then the DD-IO will be disabled.
If the volume size is greater than 2TB then the DD-IO will be disabled. If the driver is not able to find a valid stripe exponent using the configured stripe size then the DD-IO will be disabled
When the DD-IO is enabled the driver will check every I/O request issued to the storage and checks whether the request is either READ6/WRITE6/READ10/WRITE10, if it is and if the complete I/O transfer is within a stripe size then the I/O is redirected to
the drive directly instead of the volume.
On completion of every I/O, if the completion is failure means if the reply is address reply with a reply frame associated with it, then the type of I/O will be checked, if the I/O is direct then the I/O will be retried to the volume once.
---
mpt2sas_base.c +32 -10
@@ -522,7 +522,8 @@ _base_display_event_data(struct MPT2SAS_ desc ="Device Status Change" ;break ;case MPI2_EVENT_IR_OPERATION_STATUS : - desc ="IR Operation Status" ; +if (!ioc->hide_ir_msg) + desc ="IR Operation Status" ;break ;case MPI2_EVENT_SAS_DISCOVERY : {
@@ -553,16 +554,20 @@ _base_display_event_data(struct MPT2SAS_ desc ="SAS Enclosure Device Status Change" ;break ;case MPI2_EVENT_IR_VOLUME : - desc ="IR Volume" ; +if (!ioc->hide_ir_msg) + desc ="IR Volume" ;break ;case MPI2_EVENT_IR_PHYSICAL_DISK : - desc ="IR Physical Disk" ; +if (!ioc->hide_ir_msg) + desc ="IR Physical Disk" ;break ;case MPI2_EVENT_IR_CONFIGURATION_CHANGE_LIST : - desc ="IR Configuration Change List" ; +if (!ioc->hide_ir_msg) + desc ="IR Configuration Change List" ;break ;case MPI2_EVENT_LOG_ENTRY_ADDED : - desc ="Log Entry Added" ; +if (!ioc->hide_ir_msg) + desc ="Log Entry Added" ;break ; }
@@ -616,7 +621,10 @@ _base_sas_log_info(struct MPT2SAS_ADAPTE originator_str ="PL" ;break ;case 2 : - originator_str ="IR" ; +if (!ioc->hide_ir_msg) + originator_str ="IR" ; +else + originator_str ="WarpDrive" ;break ; }
@@ -1508,6 +1516,7 @@ mpt2sas_base_free_smid(struct MPT2SAS_AD } ioc->scsi_lookup[i].cb_idx =0xFF ; ioc->scsi_lookup[i].scmd =NULL ; + ioc->scsi_lookup[i].direct_io =0 ;list_add_tail (&ioc->scsi_lookup[i].tracker_list, &ioc->free_list);spin_unlock_irqrestore (&ioc->scsi_lookup_lock, flags);
@@ -1795,10 +1804,12 @@ _base_display_ioc_capabilities(struct MPprintk ("), " );printk ("Capabilities=(" ); -if (ioc->facts.IOCCapabilities & -MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID ) { -printk ("Raid" ); - i++; +if (!ioc->hide_ir_msg) { +if (ioc->facts.IOCCapabilities & +MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID ) { +printk ("Raid" ); + i++; + } }if (ioc->facts.IOCCapabilities &MPI2_IOCFACTS_CAPABILITY_TLR ) {
@@ -3631,6 +3642,7 @@ _base_make_ioc_operational(struct MPT2SAu32 reply_address;u16 smid;struct _tr_list *delayed_tr, *delayed_tr_next; +u8 hide_flag;dinitprintk (ioc,printk (MPT2SAS_INFO_FMT "%s\n" , ioc->name, __func__));
@@ -3657,6 +3669,7 @@ _base_make_ioc_operational(struct MPT2SA ioc->scsi_lookup[i].cb_idx =0xFF ; ioc->scsi_lookup[i].smid = smid; ioc->scsi_lookup[i].scmd =NULL ; + ioc->scsi_lookup[i].direct_io =0 ;list_add_tail (&ioc->scsi_lookup[i].tracker_list, &ioc->free_list); }
@@ -3717,6 +3730,15 @@ _base_make_ioc_operational(struct MPT2SAif (sleep_flag ==CAN_SLEEP )_base_static_config_pages (ioc); +if (ioc->wait_for_port_enable_to_complete && ioc->is_warpdrive) { +if (ioc->manu_pg10.OEMIdentifier ==0x80 ) { + hide_flag = (u8) (ioc->manu_pg10.OEMSpecificFlags0 & +MFG_PAGE10_HIDE_SSDS_MASK ); +if (hide_flag !=MFG_PAGE10_HIDE_SSDS_MASK ) + ioc->mfg_pg10_hide_flag = hide_flag; + } + } +if (ioc->wait_for_port_enable_to_complete) {if (diag_buffer_enable !=0 )mpt2sas_enable_diag_buffer (ioc, diag_buffer_enable);
mpt2sas_base.h +44 -5
137 lines not on this page · raw message
mpt2sas_ctl.c +4 -1
@@ -1034,7 +1034,10 @@ _ctl_getiocinfo(void __user *arg) __func__));memset (&karg,0 ,sizeof (karg)); - karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2 ; +if (ioc->is_warpdrive) + karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2_SSS6200 ; +else + karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2 ;if (ioc->pfacts) karg.port_number = ioc->pfacts[0 ].PortNumber;pci_read_config_byte (ioc->pdev,PCI_CLASS_REVISION , &revision);
mpt2sas_ctl.h +1 -0
@@ -133,6 +133,7 @@ struct mpt2_ioctl_pci_info {#define MPT2_IOCTL_INTERFACE_FC_IP (0x02)#define MPT2_IOCTL_INTERFACE_SAS (0x03)#define MPT2_IOCTL_INTERFACE_SAS2 (0x04) +#define MPT2_IOCTL_INTERFACE_SAS2_SSS6200 (0x05)#define MPT2_IOCTL_VERSION_LENGTH (32)/**
mpt2sas_scsih.c +556 -58
869 lines not on this page · raw message
James,
Any feedback on this patch submission? I observe that this patch is not following relative depth. It has "mpt2sas-phase8.0_wd/mpt2sas_base.c" path, so need to apply using -p1 instead of -p4.
Is there any need to resend patch with correct relative depth? Please let me know I will resend in that case.
~ Kashyap
Quoted 1,383 lines
-----Original Message-----
From: [email protected] [mailto:linux-scsi- [email protected]] On Behalf Of Kashyap, Desai
Sent: Thursday, February 03, 2011 3:38 PM
To: [email protected]
Cc: [email protected]; Moore, Eric; Prakash, Sathya
Subject: [PATCH] mpt2sas : WarpDrive New product SSS6200 support addedIntroduction
This patch has
Support for the new solid state device product SSS6200 from LSI and relavent
features w.r.t SSS6200.The major feature added in this driver is supporting Direct-I/O to the SSS6200 storage.There are some additional changes done to avoid exposing
the RAID member disks to the OS and hiding/exposing drives based on the OEM Specific Flag in Manufacturing Page10 (this is required to handle specific changes in the SSS6200 firmware).Each and every changes are listed below.
1. Hiding IR related messages.
For SSS6200, the driver is modified not to print IR related events. Even if the debugging is enabled the IR related messages will not be displayed.
In some places if there is a need to display a message related to IR the
string "IR" is replaced with string "DD" and the string "volume" is replaced
with "direct drive". But the function names are not changed hence there are
some places where the reference to volume can be seen if debug level is set.2. Removed RAID transport support
In Linux the user can retrieve RAID volume information from the sysfs directory.
This support is removed for SSS6200.3. Direct I/O support.
The driver tries to enable direct I/O when a volume is reported to the driver
by the firmware through IRCC events and the driver does this just before
reporting to the OS, hence all the OS issued I/O can go through direct path
if they can, The first validation is to see whether the manufacturing page10
flag is set to expose all drives always. If that is set, the driver will not
enable direct I/O and displays the message "DDIO" is disabled globally as
drives are exposed. The driver checks whether there is more than one volume
in the controller, if so the direct I/O will be disabled globally for all
volumes in the controller and the message displayed will be "DDIO is disabled
globally as number of drives > 1.
If retrieving number of PD is failed the driver will not enable direct I/O
and displays the message Failure in computing number of drives DDIO disabled.
If memory allocation for RAIDVolumePage0 is failed, the driver will not enable
direct I/O and displays the message Memory allocation failure for RVPG0 DDIO disabled. If retrieving RAIDVolumePage0 is failed the driver will
not enable direct I/O and displays the message Failure in retrieving RVPG0 DDIO disabledIf the number of PD in a volume is greater than 8, then the direct I/O will
be disabled.
If any of individual drives handle retrieval is failed then the DD-IO will
be disabled.
If the volume is not RAID0 or if the block size is not 512 then the DD- IO will
be disabled.
If the volume size is greater than 2TB then the DD-IO will be disabled. If the driver is not able to find a valid stripe exponent using the configured
stripe size then the DD-IO will be disabledWhen the DD-IO is enabled the driver will check every I/O request issued to
the storage and checks whether the request is either READ6/WRITE6/READ10/WRITE10, if it is and if the complete I/O transfer is within a stripe size then the I/O is redirected to
the drive directly instead of the volume.On completion of every I/O, if the completion is failure means if the reply
is address reply with a reply frame associated with it, then the type of I/O
will be checked, if the I/O is direct then the I/O will be retried to the volume once.Signed-off-by Kashyap Desai <[email protected]>Reviewed-by Eric Moore <[email protected]>Reviewed-by Sathya Prakash <[email protected]>---
diff -aurp
mpt2sas-phase8.0/mpt2sas_base.cmpt2sas-phase8.0_wd/mpt2sas_base.cmpt2sas_base.c 2011-01-27 20:48:35.080000040 renamed from mpt2sas_base.c 2011-01-18 11:33:41.384202609 +0530 +33
-10+0530@@ -522,7 +522,8 @@ _base_display_event_data(struct MPT2SAS_ desc = "Device Status Change"; break; case MPI2_EVENT_IR_OPERATION_STATUS: - desc = "IR Operation Status"; + if (!ioc->hide_ir_msg) + desc = "IR Operation Status"; break; case MPI2_EVENT_SAS_DISCOVERY: {@@ -553,16 +554,20 @@ _base_display_event_data(struct MPT2SAS_ desc = "SAS Enclosure Device Status Change"; break; case MPI2_EVENT_IR_VOLUME: - desc = "IR Volume"; + if (!ioc->hide_ir_msg) + desc = "IR Volume"; break; case MPI2_EVENT_IR_PHYSICAL_DISK: - desc = "IR Physical Disk"; + if (!ioc->hide_ir_msg) + desc = "IR Physical Disk"; break; case MPI2_EVENT_IR_CONFIGURATION_CHANGE_LIST: - desc = "IR Configuration Change List"; + if (!ioc->hide_ir_msg) + desc = "IR Configuration Change List"; break; case MPI2_EVENT_LOG_ENTRY_ADDED: - desc = "Log Entry Added"; + if (!ioc->hide_ir_msg) + desc = "Log Entry Added"; break; }@@ -616,7 +621,10 @@ _base_sas_log_info(struct MPT2SAS_ADAPTE originator_str = "PL"; break; case 2: - originator_str = "IR"; + if (!ioc->hide_ir_msg) + originator_str = "IR"; + else + originator_str = "WarpDrive"; break; }@@ -1508,6 +1516,7 @@ mpt2sas_base_free_smid(struct MPT2SAS_AD } ioc->scsi_lookup[i].cb_idx = 0xFF; ioc->scsi_lookup[i].scmd = NULL; + ioc->scsi_lookup[i].direct_io = 0; list_add_tail(&ioc->scsi_lookup[i].tracker_list, &ioc->free_list); spin_unlock_irqrestore(&ioc->scsi_lookup_lock, flags);@@ -1795,10 +1804,12 @@ _base_display_ioc_capabilities(struct MP printk("), "); printk("Capabilities=("); - if (ioc->facts.IOCCapabilities & - MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID) { - printk("Raid"); - i++; + if (!ioc->hide_ir_msg) { + if (ioc->facts.IOCCapabilities & + MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID) { + printk("Raid"); + i++; + } } if (ioc->facts.IOCCapabilities & MPI2_IOCFACTS_CAPABILITY_TLR) {@@ -3631,6 +3642,7 @@ _base_make_ioc_operational(struct MPT2SA u32 reply_address; u16 smid; struct _tr_list *delayed_tr, *delayed_tr_next; + u8 hide_flag; dinitprintk(ioc, printk(MPT2SAS_INFO_FMT "%s\n", ioc->name, __func__));@@ -3657,6 +3669,7 @@ _base_make_ioc_operational(struct MPT2SA ioc->scsi_lookup[i].cb_idx = 0xFF; ioc->scsi_lookup[i].smid = smid; ioc->scsi_lookup[i].scmd = NULL; + ioc->scsi_lookup[i].direct_io = 0; list_add_tail(&ioc->scsi_lookup[i].tracker_list, &ioc->free_list); }@@ -3717,6 +3730,15 @@ _base_make_ioc_operational(struct MPT2SA if (sleep_flag == CAN_SLEEP) _base_static_config_pages(ioc); + if (ioc->wait_for_port_enable_to_complete && ioc->is_warpdrive) { + if (ioc->manu_pg10.OEMIdentifier == 0x80) { + hide_flag = (u8) (ioc->manu_pg10.OEMSpecificFlags0 & + MFG_PAGE10_HIDE_SSDS_MASK); + if (hide_flag != MFG_PAGE10_HIDE_SSDS_MASK) + ioc->mfg_pg10_hide_flag = hide_flag; + } + } + if (ioc->wait_for_port_enable_to_complete) { if (diag_buffer_enable != 0) mpt2sas_enable_diag_buffer(ioc, diag_buffer_enable);diff -aurp
mpt2sas-phase8.0/mpt2sas_base.hmpt2sas-phase8.0_wd/mpt2sas_base.hmpt2sas_base.h 2011-01-27 20:57:45.016000126 renamed from mpt2sas_base.h 2011-01-18 11:33:45.711139872 +0530 +29
-2+0530@@ -69,11 +69,11 @@ #define MPT2SAS_DRIVER_NAME "mpt2sas" #define MPT2SAS_AUTHOR "LSI Corporation <[email protected]>" #define MPT2SAS_DESCRIPTION "LSI MPT Fusion SAS 2.0 Device Driver" -#define MPT2SAS_DRIVER_VERSION "08.100.00.00" +#define MPT2SAS_DRIVER_VERSION "08.100.00.01" #define MPT2SAS_MAJOR_VERSION 08 #define MPT2SAS_MINOR_VERSION 100 #define MPT2SAS_BUILD_VERSION 00 -#define MPT2SAS_RELEASE_VERSION 00 +#define MPT2SAS_RELEASE_VERSION 01 /* * Set MPT2SAS_SG_DEPTH value based on user input.@@ -169,6 +169,16 @@ #define MPT2SAS_INTEL_RMS2LL040_SSDID 0x350F /* + * WarpDrive Specific Log codes + */ + +#define MPT2_WARPDRIVE_LOGENTRY (0x8002) +#define MPT2_WARPDRIVE_LC_SSDT (0x41) +#define MPT2_WARPDRIVE_LC_SSDLW (0x43) +#define MPT2_WARPDRIVE_LC_SSDLF (0x44) +#define MPT2_WARPDRIVE_LC_BRMF (0x4D) + +/* * per target private data */ #define MPT_TARGET_FLAGS_RAID_COMPONENT 0x01@@ -179,6 +189,7 @@ * struct MPT2SAS_TARGET - starget private hostdata * @starget: starget object * @sas_address: target sas address + * @raid_device: raid_device pointer to access volume data * @handle: device handle * @num_luns: number luns * @flags: MPT_TARGET_FLAGS_XXX flags@@ -188,6 +199,7 @@ struct MPT2SAS_TARGET { struct scsi_target *starget; u64 sas_address; + struct _raid_device *raid_device; u16 handle; int num_luns; u32 flags;@@ -195,6 +207,7 @@ struct MPT2SAS_TARGET { u8 tm_busy; }; + /* * per device private data */@@ -242,6 +255,12 @@ typedef struct _MPI2_CONFIG_PAGE_MAN_10 MPI2_POINTER PTR_MPI2_CONFIG_PAGE_MAN_10, Mpi2ManufacturingPage10_t, MPI2_POINTER pMpi2ManufacturingPage10_t; +#define MFG_PAGE10_HIDE_SSDS_MASK (0x00000003) +#define MFG_PAGE10_HIDE_ALL_DISKS (0x00) +#define MFG_PAGE10_EXPOSE_ALL_DISKS (0x01) +#define MFG_PAGE10_HIDE_IF_VOL_PRESENT (0x02) + + struct MPT2SAS_DEVICE { struct MPT2SAS_TARGET *sas_target; unsigned int lun;@@ -321,6 +340,7 @@ struct _sas_device { * @sdev: scsi device struct (volumes are single lun) * @wwid: unique identifier for the volume * @handle: device handle + * @block_size: Block size of the volume * @id: target id * @channel: target channel * @volume_type: the raid level@@ -328,20 +348,33 @@ struct _sas_device { * @num_pds: number of hidden raid components * @responding: used in _scsih_raid_device_mark_responding * @percent_complete: resync percent complete + * @direct_io_enabled: Whether direct io to PDs are allowed or not + * @stripe_exponent: X where 2powX is the stripe sz in blocks + * @max_lba: Maximum number of LBA in the volume + * @stripe_sz: Stripe Size of the volume + * @device_info: Device info of the volume member disk + * @pd_handle: Array of handles of the physical drives for direct I/Oin le16
*/mpt2sas_base.h 2011-01-27 20:57:45.016000126 renamed from mpt2sas_base.h 2011-01-18 11:33:45.711139872 +0530 +16
-3+#define MPT_MAX_WARPDRIVE_PDS 8 struct _raid_device { struct list_head list; struct scsi_target *starget; struct scsi_device *sdev; u64 wwid; u16 handle; + u16 block_sz; int id; int channel; u8 volume_type; - u32 device_info; u8 num_pds; u8 responding; u8 percent_complete; + u8 direct_io_enabled; + u8 stripe_exponent; + u64 max_lba; + u32 stripe_sz; + u32 device_info; + u16 pd_handle[MPT_MAX_WARPDRIVE_PDS]; }; /**@@ -450,6 +483,7 @@ struct chain_tracker { * @smid: system message id * @scmd: scsi request pointer * @cb_idx: callback index + * @direct_io: To indicate whether I/O is direct (WARPDRIVE) * @chain_list: list of chains associated to this IO * @tracker_list: list of free request (ioc->free_list) */@@ -457,14 +491,14 @@ struct scsiio_tracker { u16 smid; struct scsi_cmnd *scmd; u8 cb_idx; + u8 direct_io; struct list_head chain_list; struct list_head tracker_list; }; /** - * struct request_tracker - misc mf request tracker + * struct request_tracker - firmware request tracker * @smid: system message id - * @scmd: scsi request pointer * @cb_idx: callback index * @tracker_list: list of free request (ioc->free_list) */@@ -812,6 +846,11 @@ struct MPT2SAS_ADAPTER { u32 diagnostic_flags[MPI2_DIAG_BUF_TYPE_COUNT]; u32 ring_buffer_offset; u32 ring_buffer_sz; + u8 is_warpdrive; + u8 hide_ir_msg; + u8 mfg_pg10_hide_flag; + u8 hide_drives; + }; typedef u8 (*MPT_CALLBACK)(struct MPT2SAS_ADAPTER *ioc, u16 smid, u8
msix_index,
diff -aurpmpt2sas-phase8.0/mpt2sas_ctl.cmpt2sas-phase8.0_wd/mpt2sas_ctl.cmpt2sas_ctl.c 2011-01-27 20:48:35.096000040 renamed from mpt2sas_ctl.c 2011-01-18 11:30:28.453140352 +0530 +5
-1+0530@@ -1034,7 +1034,10 @@ _ctl_getiocinfo(void __user *arg) __func__)); memset(&karg, 0 , sizeof(karg)); - karg.adapter_type = MPT2_IOCTL_INTERFACE_SAS2; + if (ioc->is_warpdrive) + karg.adapter_type = MPT2_IOCTL_INTERFACE_SAS2_SSS6200; + else + karg.adapter_type = MPT2_IOCTL_INTERFACE_SAS2; if (ioc->pfacts) karg.port_number = ioc->pfacts[0].PortNumber; pci_read_config_byte(ioc->pdev, PCI_CLASS_REVISION, &revision);diff -aurp
mpt2sas-phase8.0/mpt2sas_ctl.hmpt2sas-phase8.0_wd/mpt2sas_ctl.hmpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +2
-0+0530@@ -133,6 +133,7 @@ struct mpt2_ioctl_pci_info { #define MPT2_IOCTL_INTERFACE_FC_IP (0x02) #define MPT2_IOCTL_INTERFACE_SAS (0x03) #define MPT2_IOCTL_INTERFACE_SAS2 (0x04) +#define MPT2_IOCTL_INTERFACE_SAS2_SSS6200 (0x05) #define MPT2_IOCTL_VERSION_LENGTH (32) /**diff -aurp
mpt2sas-phase8.0/mpt2sas_scsih.cmpt2sas-phase8.0_wd/mpt2sas_scsih.c
---mpt2sas-phase8.0/mpt2sas_scsih.c2011-01-18 11:33:43.225202675 +0530
+++mpt2sas-phase8.0_wd/mpt2sas_scsih.c2011-02-03 15:42:45.974149344
+0530mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +4
-0@@ -233,6 +233,9 @@ static struct pci_device_id scsih_pci_ta PCI_ANY_ID, PCI_ANY_ID }, { MPI2_MFGPAGE_VENDORID_LSI, MPI2_MFGPAGE_DEVID_SAS2308_3, PCI_ANY_ID, PCI_ANY_ID }, + /* SSS6200 */ + { MPI2_MFGPAGE_VENDORID_LSI, MPI2_MFGPAGE_DEVID_SSS6200, + PCI_ANY_ID, PCI_ANY_ID }, {0} /* Terminating entry */ }; MODULE_DEVICE_TABLE(pci, scsih_pci_table);@@ -1256,6 +1259,7 @@ _scsih_target_alloc(struct scsi_target * sas_target_priv_data->handle = raid_device->handle; sas_target_priv_data->sas_address = raid_device- >wwid; sas_target_priv_data->flags |= MPT_TARGET_FLAGS_VOLUME; + sas_target_priv_data->raid_device = raid_device; raid_device->starget = starget;} spin_unlock_irqrestore(&ioc->raid_device_lock, flags);mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +62
-1@@ -1455,7 +1459,10 @@ static int _scsih_is_raid(struct device *dev) { struct scsi_device *sdev = to_scsi_device(dev); + struct MPT2SAS_ADAPTER *ioc = shost_priv(sdev->host); + if (ioc->is_warpdrive) + return 0; return (sdev->channel == RAID_CHANNEL) ? 1 : 0; }@@ -1480,7 +1487,7 @@ _scsih_get_resync(struct device *dev) sdev->channel); spin_unlock_irqrestore(&ioc->raid_device_lock, flags); - if (!raid_device) + if (!raid_device || ioc->is_warpdrive) goto out; if (mpt2sas_config_get_raid_volume_pg0(ioc, &mpi_reply, &vol_pg0,@@ -1640,6 +1647,212 @@ _scsih_get_volume_capabilities(struct MP kfree(vol_pg0); } +/** + * _scsih_disable_ddio - Disable direct I/O for all the volumes + * @ioc: per adapter object + */ +static void +_scsih_disable_ddio(struct MPT2SAS_ADAPTER *ioc) +{ + Mpi2RaidVolPage1_t vol_pg1; + Mpi2ConfigReply_t mpi_reply; + struct _raid_device *raid_device; + u16 handle; + u16 ioc_status; + + handle = 0xFFFF; + while (!(mpt2sas_config_get_raid_volume_pg1(ioc, &mpi_reply, + &vol_pg1, MPI2_RAID_VOLUME_PGAD_FORM_GET_NEXT_HANDLE, handle))) { + ioc_status = le16_to_cpu(mpi_reply.IOCStatus) & + MPI2_IOCSTATUS_MASK; + if (ioc_status == MPI2_IOCSTATUS_CONFIG_INVALID_PAGE) + break; + handle = le16_to_cpu(vol_pg1.DevHandle); + raid_device = _scsih_raid_device_find_by_handle(ioc, handle); + if (raid_device) + raid_device->direct_io_enabled = 0; + } + return; +} + + +/** + * _scsih_get_num_volumes - Get number of volumes in the ioc + * @ioc: per adapter object + */ +static u8 +_scsih_get_num_volumes(struct MPT2SAS_ADAPTER *ioc) +{ + Mpi2RaidVolPage1_t vol_pg1; + Mpi2ConfigReply_t mpi_reply; + u16 handle; + u8 vol_cnt = 0; + u16 ioc_status; + + handle = 0xFFFF; + while (!(mpt2sas_config_get_raid_volume_pg1(ioc, &mpi_reply, + &vol_pg1, MPI2_RAID_VOLUME_PGAD_FORM_GET_NEXT_HANDLE, handle))) { + ioc_status = le16_to_cpu(mpi_reply.IOCStatus) & + MPI2_IOCSTATUS_MASK; + if (ioc_status == MPI2_IOCSTATUS_CONFIG_INVALID_PAGE) + break; + vol_cnt++; + handle = le16_to_cpu(vol_pg1.DevHandle); + } + return vol_cnt; +} + + +/** + * _scsih_init_warpdrive_properties - Set properties for warpdrivedirect I/O.
+ * @ioc: per adapter object
+ * @raid_device: theraid_deviceobject
+ */mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +20
-0+static void +_scsih_init_warpdrive_properties(struct MPT2SAS_ADAPTER *ioc, + struct _raid_device *raid_device) +{ + Mpi2RaidVolPage0_t *vol_pg0; + Mpi2RaidPhysDiskPage0_t pd_pg0; + Mpi2ConfigReply_t mpi_reply; + u16 sz; + u8 num_pds, count; + u64 mb = 1024 * 1024; + u64 tb_2 = 2 * mb * mb; + u64 capacity; + u32 stripe_sz; + u8 i, stripe_exp; + + if (!ioc->is_warpdrive) + return; + + if (ioc->mfg_pg10_hide_flag == MFG_PAGE10_EXPOSE_ALL_DISKS) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +6
-0+ "globally as drives are exposed\n", ioc->name); + return; + } + if (_scsih_get_num_volumes(ioc) > 1) { + _scsih_disable_ddio(ioc); + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +6
-0+ "globally as number of drives > 1\n", ioc->name); + return; + } + if ((mpt2sas_config_get_number_pds(ioc, raid_device->handle, + &num_pds)) || !num_pds) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +9
-0+ "Failure in computing number of drives\n", ioc->name); + return; + } + + sz = offsetof(Mpi2RaidVolPage0_t, PhysDisk) + (num_pds * + sizeof(Mpi2RaidVol0PhysDisk_t)); + vol_pg0 = kzalloc(sz, GFP_KERNEL); + if (!vol_pg0) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +6
-0+ "Memory allocation failure for RVPG0\n", ioc->name); + return; + } + + if ((mpt2sas_config_get_raid_volume_pg0(ioc, &mpi_reply, vol_pg0, + MPI2_RAID_VOLUME_PGAD_FORM_HANDLE, raid_device->handle,sz))) {
+ printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled
"mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +7
-0+ "Failure in retrieving RVPG0\n", ioc->name); + kfree(vol_pg0); + return; + } + + /* + * WARPDRIVE:If number of physical disks in a volume exceeds themax pds
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +4
-0+ * assumed for WARPDRIVE, disable direct I/O + */ + if (num_pds > MPT_MAX_WARPDRIVE_PDS) { + printk(MPT2SAS_WARN_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +13
-0+ "for the drive with handle(0x%04x): num_mem=%d, " + "max_mem_allowed=%d\n", ioc->name, raid_device->handle, + num_pds, MPT_MAX_WARPDRIVE_PDS); + kfree(vol_pg0); + return; + } + for (count = 0; count < num_pds; count++) { + if (mpt2sas_config_get_phys_disk_pg0(ioc, &mpi_reply, + &pd_pg0, MPI2_PHYSDISK_PGAD_FORM_PHYSDISKNUM, + vol_pg0->PhysDisk[count].PhysDiskNum) || + pd_pg0.DevHandle == MPT2SAS_INVALID_DEVICE_HANDLE) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is " + "disabled for the drive with handle(0x%04x)member"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +6
-0+ "handle retrieval failed for member number=%d\n", + ioc->name, raid_device->handle, + vol_pg0->PhysDisk[count].PhysDiskNum); + goto out_error; + } + raid_device->pd_handle[count] =
le16_to_cpu(pd_pg0.DevHandle);mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +4
-0+ } + + /* + * Assumption for WD: Direct I/O is not supported if the volumeis
+ * not RAID0, if the stripe size is not 64KB, if the block size
ismpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +5
-0+ * not 512 and if the volume size is >2TB + */ + if (raid_device->volume_type != MPI2_RAID_VOL_TYPE_RAID0 || + le16_to_cpu(vol_pg0->BlockSize) != 512) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +13
-0+ "for the drive with handle(0x%04x): type=%d, " + "s_sz=%uK, blk_size=%u\n", ioc->name, + raid_device->handle, raid_device->volume_type, + le32_to_cpu(vol_pg0->StripeSize)/2, + le16_to_cpu(vol_pg0->BlockSize)); + goto out_error; + } + + capacity = (u64) le16_to_cpu(vol_pg0->BlockSize) * + (le64_to_cpu(vol_pg0->MaxLBA) + 1); + + if (capacity > tb_2) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +15
-0+ "for the drive with handle(0x%04x) since drive sz > 2TB\n", + ioc->name, raid_device->handle); + goto out_error; + } + + stripe_sz = le32_to_cpu(vol_pg0->StripeSize); + stripe_exp = 0; + for (i = 0; i < 32; i++) { + if (stripe_sz & 1) + break; + stripe_exp++; + stripe_sz >>= 1; + } + if (i == 32) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
+ "for the drive with handle(0x%04x) invalid stripe sz
%uK\n",mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +8
-0+ ioc->name, raid_device->handle, + le32_to_cpu(vol_pg0->StripeSize)/2); + goto out_error; + } + raid_device->stripe_exponent = stripe_exp; + raid_device->direct_io_enabled = 1; + + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is Enabled for thedrive"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +3
-0+ " with handle(0x%04x)\n", ioc->name, raid_device->handle); + /* + * WARPDRIVE: Though the following fields are not used for directIO,
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +30
-6+ * stored for future purpose: + */ + raid_device->max_lba = le64_to_cpu(vol_pg0->MaxLBA); + raid_device->stripe_sz = le32_to_cpu(vol_pg0->StripeSize); + raid_device->block_sz = le16_to_cpu(vol_pg0->BlockSize); + + + kfree(vol_pg0); + return; + +out_error: + raid_device->direct_io_enabled = 0; + for (count = 0; count < num_pds; count++) + raid_device->pd_handle[count] = 0; + kfree(vol_pg0); + return; +} /** * _scsih_enable_tlr - setting TLR flags@@ -1710,6 +1923,11 @@ _scsih_slave_configure(struct scsi_devic _scsih_get_volume_capabilities(ioc, raid_device); + /* + * WARPDRIVE: Initialize the required data for Direct IO + */ + _scsih_init_warpdrive_properties(ioc, raid_device); + /* RAID Queue Depth Support * IS volume = underlying qdepth of drive type, either * MPT2SAS_SAS_QUEUE_DEPTH or MPT2SAS_SATA_QUEUE_DEPTH@@ -1757,14 +1975,16 @@ _scsih_slave_configure(struct scsi_devic break; } - sdev_printk(KERN_INFO, sdev, "%s: " - "handle(0x%04x), wwid(0x%016llx), pd_count(%d), type(%s)\n", - r_level, raid_device->handle, - (unsigned long long)raid_device->wwid, - raid_device->num_pds, ds); + if (!ioc->hide_ir_msg) + sdev_printk(KERN_INFO, sdev, "%s: handle(0x%04x), " + "wwid(0x%016llx), pd_count(%d), type(%s)\n", + r_level, raid_device->handle, + (unsigned long long)raid_device->wwid, + raid_device->num_pds, ds); _scsih_change_queue_depth(sdev, qdepth, SCSI_QDEPTH_DEFAULT); /* raid transport support */ - _scsih_set_level(sdev, raid_device); + if (!ioc->is_warpdrive) + _scsih_set_level(sdev, raid_device); return 0;}mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +5
-1@@ -2182,16 +2402,20 @@ _scsih_tm_display_info(struct MPT2SAS_AD struct MPT2SAS_TARGET *priv_target = starget->hostdata; struct _sas_device *sas_device = NULL; unsigned long flags; + char *device_str = NULL; if (!priv_target) return; + if (ioc->hide_ir_msg) + device_str = "WarpDrive"; + else + device_str = "volume"; scsi_print_command(scmd); if (priv_target->flags & MPT_TARGET_FLAGS_VOLUME) { - starget_printk(KERN_INFO, starget, "volume handle(0x%04x),"
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +2
-3- "volume wwid(0x%016llx)\n", - priv_target->handle, - (unsigned long long)priv_target->sas_address); + starget_printk(KERN_INFO, starget, "%s handle(0x%04x), " + "%s wwid(0x%016llx)\n", device_str, priv_target-Quoted 1 line
handle,
+
device_str, (unsigned long long)priv_target-Quoted 1 line
sas_address);} else { spin_lock_irqsave(&ioc->sas_device_lock, flags); sas_device =mpt2sas_scsih_sas_device_find_by_sas_address(ioc,
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +3
-0@@ -3130,6 +3354,9 @@ _scsih_check_ir_config_unhide_events(str a = 0; b = 0; + if (ioc->is_warpdrive) + return; + /* Volume Resets for Deleted or Removed */ element = (Mpi2EventIrConfigElement_t *)&event_data- >ConfigElement[0];for (i = 0; i < event_data->NumElements; i++, element++) {mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +55
-0@@ -3347,6 +3574,105 @@ _scsih_eedp_error_handling(struct scsi_c } /** + * _scsih_scsi_direct_io_get - returns direct io flag + * @ioc: per adapter object + * @smid: system request message index + * + * Returns the smid stored scmd pointer. + */ +static inline u8 +_scsih_scsi_direct_io_get(struct MPT2SAS_ADAPTER *ioc, u16 smid) +{ + return ioc->scsi_lookup[smid - 1].direct_io; +} + +/** + * _scsih_scsi_direct_io_set - sets direct io flag + * @ioc: per adapter object + * @smid: system request message index + * @direct_io: Zero or non-zero value to set in the direct_io flag + * + * Returns Nothing. + */ +static inline void +_scsih_scsi_direct_io_set(struct MPT2SAS_ADAPTER *ioc, u16 smid, u8 direct_io) +{ + ioc->scsi_lookup[smid - 1].direct_io = direct_io; +} + + +/** + * _scsih_setup_direct_io - setup MPI request for WARPDRIVE Direct I/O + * @ioc: per adapter object + * @scmd: pointer to scsi command object + * @raid_device: pointer to raid device data structure + * @mpi_request: pointer to the SCSI_IO reqest message frame + * @smid: system request message index + * + * Returns nothing + */ +static void +_scsih_setup_direct_io(struct MPT2SAS_ADAPTER *ioc, struct scsi_cmnd *scmd, + struct _raid_device *raid_device, Mpi2SCSIIORequest_t *mpi_request, + u16 smid) +{ + u32 v_lba, p_lba, stripe_off, stripe_unit, column, io_size; + u32 stripe_sz, stripe_exp; + u8 num_pds, *cdb_ptr, *tmp_ptr, *lba_ptr1, *lba_ptr2; + u8 cdb0 = scmd->cmnd[0]; + + /* + * Try Direct I/O to RAID memeber disks + */ + if (cdb0 == READ_16 || cdb0 == READ_10 || + cdb0 == WRITE_16 || cdb0 == WRITE_10) { + cdb_ptr = mpi_request->CDB.CDB32; + + if ((cdb0 < READ_16) || !(cdb_ptr[2] | cdb_ptr[3] |cdb_ptr[4]
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +4
-0+ | cdb_ptr[5])) { + io_size = scsi_bufflen(scmd) >> 9; + /* get virtual lba */ + lba_ptr1 = lba_ptr2 = (cdb0 < READ_16) ? &cdb_ptr[2]:
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +43
-2+ &cdb_ptr[6]; + tmp_ptr = (u8 *)&v_lba + 3; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr = *lba_ptr1; + + if (((u64)v_lba + (u64)io_size - 1) <= + (u32)raid_device->max_lba) { + stripe_sz = raid_device->stripe_sz; + stripe_exp = raid_device->stripe_exponent; + stripe_off = v_lba & (stripe_sz - 1); + + /* Check whether IO falls within a stripe */ + if ((stripe_off + io_size) <= stripe_sz) { + num_pds = raid_device->num_pds; + p_lba = v_lba >> stripe_exp; + stripe_unit = p_lba / num_pds; + column = p_lba % num_pds; + p_lba = (stripe_unit << stripe_exp) + + stripe_off; + mpi_request->DevHandle = + cpu_to_le16(raid_device-> + pd_handle[column]); + tmp_ptr = (u8 *)&p_lba + 3; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2 = *tmp_ptr; + /* + * WD: To indicate this I/O is directI/O + */ + _scsih_scsi_direct_io_set(ioc, smid, 1); + } + } + } + } +} + +/** * _scsih_qcmd - main scsi request entry point * @scmd: pointer to scsi command object * @done: function pointer to be invoked on completion@@ -3363,6 +3689,7 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd, struct MPT2SAS_ADAPTER *ioc = shost_priv(scmd->device->host); struct MPT2SAS_DEVICE *sas_device_priv_data; struct MPT2SAS_TARGET *sas_target_priv_data; + struct _raid_device *raid_device; Mpi2SCSIIORequest_t *mpi_request; u32 mpi_control; u16 smid;@@ -3424,8 +3751,10 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd, } else mpi_control |= MPI2_SCSIIO_CONTROL_SIMPLEQ; - /* Make sure Device is not raid volume */ - if (!_scsih_is_raid(&scmd->device->sdev_gendev) && + /* Make sure Device is not raid volume. + * We do not expose raid functionality to upper layer forwarpdrive.
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +2
-0+ */ + if (!ioc->is_warpdrive && _scsih_is_raid(&scmd->device-Quoted 1 line
sdev_gendev) &&sas_is_tlr_enabled(scmd->device) && scmd->cmd_len != 32) mpi_control |= MPI2_SCSIIO_CONTROL_TLR_ON;mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +6
-1@@ -3473,9 +3802,14 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd, } } + raid_device = sas_target_priv_data->raid_device; + if (raid_device && raid_device->direct_io_enabled) + _scsih_setup_direct_io(ioc, scmd, raid_device, mpi_request, + smid); + if (likely(mpi_request->Function == MPI2_FUNCTION_SCSI_IO_REQUEST)) mpt2sas_base_put_smid_scsi_io(ioc, smid, - sas_device_priv_data->sas_target->handle); + le16_to_cpu(mpi_request->DevHandle)); else mpt2sas_base_put_smid_default(ioc, smid);return 0;mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +8
-2@@ -3540,10 +3874,16 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAP unsigned long flags; struct scsi_target *starget = scmd->device->sdev_target; struct MPT2SAS_TARGET *priv_target = starget->hostdata; + char *device_str = NULL; if (!priv_target) return; + if (ioc->hide_ir_msg) + device_str = "WarpDrive"; + else + device_str = "volume"; + if (log_info == 0x31170000) return;@@ -3660,8 +4000,8 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAP scsi_print_command(scmd); if (priv_target->flags & MPT_TARGET_FLAGS_VOLUME) { - printk(MPT2SAS_WARN_FMT "\tvolume wwid(0x%016llx)\n", ioc- >name, - (unsigned long long)priv_target->sas_address); + printk(MPT2SAS_WARN_FMT "\t%s wwid(0x%016llx)\n", ioc- >name, + device_str, (unsigned long long)priv_target- >sas_address);} else { spin_lock_irqsave(&ioc->sas_device_lock, flags); sas_device =mpt2sas_scsih_sas_device_find_by_sas_address(ioc,
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +16
-1@@ -3840,6 +4180,20 @@ _scsih_io_done(struct MPT2SAS_ADAPTER *i scmd->result = DID_NO_CONNECT << 16; goto out; } + /* + * WARPDRIVE: If direct_io is set then it is directIO, + * the failed direct I/O should be redirected to volume + */ + if (_scsih_scsi_direct_io_get(ioc, smid)) { + _scsih_scsi_direct_io_set(ioc, smid, 0); + memcpy(mpi_request->CDB.CDB32, scmd->cmnd, scmd->cmd_len); + mpi_request->DevHandle = + cpu_to_le16(sas_device_priv_data->sas_target->handle); + mpt2sas_base_put_smid_scsi_io(ioc, smid, + sas_device_priv_data->sas_target->handle); + return 0; + } + /* turning off TLR */ scsi_state = mpi_reply->SCSIState;@@ -3848,7 +4202,10 @@ _scsih_io_done(struct MPT2SAS_ADAPTER *i le32_to_cpu(mpi_reply->ResponseInfo) & 0xFF; if (!sas_device_priv_data->tlr_snoop_check) { sas_device_priv_data->tlr_snoop_check++; - if (!_scsih_is_raid(&scmd->device->sdev_gendev) && + /* Make sure Device is not raid volume. + * We do not expose raid functionality to upper layer forwarpdrive.
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +2
-0+ */ + if (!ioc->is_warpdrive && !_scsih_is_raid(&scmd->device-Quoted 1 line
sdev_gendev) &&sas_is_tlr_enabled(scmd->device) && response_code == MPI2_SCSITASKMGMT_RSP_INVALID_FRAME) { sas_disable_tlr(scmd->device);mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +7
-3@@ -4681,8 +5038,10 @@ _scsih_remove_device(struct MPT2SAS_ADAP _scsih_ublock_io_device(ioc, sas_device_backup.handle); - mpt2sas_transport_port_remove(ioc, sas_device_backup.sas_address, - sas_device_backup.sas_address_parent); + if (!ioc->hide_drives) + mpt2sas_transport_port_remove(ioc, + sas_device_backup.sas_address, + sas_device_backup.sas_address_parent); printk(MPT2SAS_INFO_FMT "removing handle(0x%04x), sas_addr" "(0x%016llx)\n", ioc->name, sas_device_backup.handle,@@ -5413,6 +5772,7 @@ _scsih_sas_pd_hide(struct MPT2SAS_ADAPTE &sas_device->volume_wwid); set_bit(handle, ioc->pd_handles); _scsih_reprobe_target(sas_device->starget, 1); + } /**@@ -5591,7 +5951,8 @@ _scsih_sas_ir_config_change_event(struct Mpi2EventDataIrConfigChangeList_t *event_data = fw_event- >event_data; #ifdef CONFIG_SCSI_MPT2SAS_LOGGING - if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK) + if ((ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK) + && !ioc->hide_ir_msg) _scsih_sas_ir_config_change_event_debug(ioc, event_data);#endif
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +10
-7@@ -5614,16 +5975,20 @@ _scsih_sas_ir_config_change_event(struct le16_to_cpu(element->VolDevHandle)); break; case MPI2_EVENT_IR_CHANGE_RC_PD_CREATED: - _scsih_sas_pd_hide(ioc, element); + if (!ioc->is_warpdrive) + _scsih_sas_pd_hide(ioc, element); break; case MPI2_EVENT_IR_CHANGE_RC_PD_DELETED: - _scsih_sas_pd_expose(ioc, element); + if (!ioc->is_warpdrive) + _scsih_sas_pd_expose(ioc, element); break; case MPI2_EVENT_IR_CHANGE_RC_HIDE: - _scsih_sas_pd_add(ioc, element); + if (!ioc->is_warpdrive) + _scsih_sas_pd_add(ioc, element); break; case MPI2_EVENT_IR_CHANGE_RC_UNHIDE: - _scsih_sas_pd_delete(ioc, element); + if (!ioc->is_warpdrive) + _scsih_sas_pd_delete(ioc, element); break; } }@@ -5654,9 +6019,10 @@ _scsih_sas_ir_volume_event(struct MPT2SA handle = le16_to_cpu(event_data->VolDevHandle); state = le32_to_cpu(event_data->NewValue); - dewtprintk(ioc, printk(MPT2SAS_INFO_FMT "%s: handle(0x%04x), " - "old(0x%08x), new(0x%08x)\n", ioc->name, __func__, handle, - le32_to_cpu(event_data->PreviousValue), state)); + if (!ioc->hide_ir_msg) + dewtprintk(ioc, printk(MPT2SAS_INFO_FMT "%s:handle(0x%04x), "
+ "old(0x%08x), new(0x%08x)\n",ioc->name,__func__,
handle,mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +3
-3+ le32_to_cpu(event_data->PreviousValue), state)); switch (state) { case MPI2_RAID_VOL_STATE_MISSING:@@ -5736,9 +6102,10 @@ _scsih_sas_ir_physical_disk_event(struct handle = le16_to_cpu(event_data->PhysDiskDevHandle); state = le32_to_cpu(event_data->NewValue); - dewtprintk(ioc, printk(MPT2SAS_INFO_FMT "%s: handle(0x%04x), " - "old(0x%08x), new(0x%08x)\n", ioc->name, __func__, handle, - le32_to_cpu(event_data->PreviousValue), state)); + if (!ioc->hide_ir_msg) + dewtprintk(ioc, printk(MPT2SAS_INFO_FMT "%s:handle(0x%04x), "
+ "old(0x%08x), new(0x%08x)\n",ioc->name,__func__,
handle,mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +6
-3+ le32_to_cpu(event_data->PreviousValue), state)); switch (state) { case MPI2_RAID_PD_STATE_ONLINE:@@ -5747,7 +6114,8 @@ _scsih_sas_ir_physical_disk_event(struct case MPI2_RAID_PD_STATE_OPTIMAL: case MPI2_RAID_PD_STATE_HOT_SPARE: - set_bit(handle, ioc->pd_handles); + if (!ioc->is_warpdrive) + set_bit(handle, ioc->pd_handles); spin_lock_irqsave(&ioc->sas_device_lock, flags); sas_device = _scsih_sas_device_find_by_handle(ioc, handle);@@ -5851,7 +6219,8 @@ _scsih_sas_ir_operation_status_event(str u16 handle; #ifdef CONFIG_SCSI_MPT2SAS_LOGGING - if (ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK) + if ((ioc->logging_level & MPT_DEBUG_EVENT_WORK_TASK) + && !ioc->hide_ir_msg) _scsih_sas_ir_operation_status_event_debug(ioc, event_data); #endif@@ -5910,7 +6279,7 @@ static void _scsih_mark_responding_sas_device(struct MPT2SAS_ADAPTER *ioc, u64 sas_address, u16 slot, u16 handle) { - struct MPT2SAS_TARGET *sas_target_priv_data; + struct MPT2SAS_TARGET *sas_target_priv_data = NULL; struct scsi_target *starget; struct _sas_device *sas_device;unsigned long flags;mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +10
-8@@ -5918,7 +6287,7 @@ _scsih_mark_responding_sas_device(struct spin_lock_irqsave(&ioc->sas_device_lock, flags); list_for_each_entry(sas_device, &ioc->sas_device_list, list) { if (sas_device->sas_address == sas_address && - sas_device->slot == slot && sas_device->starget) { + sas_device->slot == slot) { sas_device->responding = 1; starget = sas_device->starget; if (starget && starget->hostdata) {@@ -5927,13 +6296,15 @@ _scsih_mark_responding_sas_device(struct sas_target_priv_data->deleted = 0; } else sas_target_priv_data = NULL; - starget_printk(KERN_INFO, sas_device->starget, - "handle(0x%04x), sas_addr(0x%016llx), enclosure " - "logical id(0x%016llx), slot(%d)\n", handle, - (unsigned long long)sas_device->sas_address, - (unsigned long long) - sas_device->enclosure_logical_id, - sas_device->slot); + if (starget) + starget_printk(KERN_INFO, starget, + "handle(0x%04x), sas_addr(0x%016llx), " + "enclosure logical id(0x%016llx), " + "slot(%d)\n", handle, + (unsigned long long)sas_device- >sas_address, + (unsigned long long) + sas_device->enclosure_logical_id, + sas_device->slot); if (sas_device->handle == handle) goto out;printk(KERN_INFO "\thandle changed
from(0x%04x)!!!\n",mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +2
-0@@ -6025,6 +6396,12 @@ _scsih_mark_responding_raid_device(struc starget_printk(KERN_INFO, raid_device->starget, "handle(0x%04x), wwid(0x%016llx)\n", handle, (unsigned long long)raid_device->wwid); + /* + * WARPDRIVE: The handles of the PDs might havechanged
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +4
-0+ * across the host reset so re-initialize the + * required data for Direct IO + */ + _scsih_init_warpdrive_properties(ioc, raid_device); if (raid_device->handle == handle) goto out; printk(KERN_INFO "\thandle changedfrom(0x%04x)!!!\n",
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +58
-12@@ -6086,18 +6463,20 @@ _scsih_search_responding_raid_devices(st } /* refresh the pd_handles */ - phys_disk_num = 0xFF; - memset(ioc->pd_handles, 0, ioc->pd_handles_sz); - while (!(mpt2sas_config_get_phys_disk_pg0(ioc, &mpi_reply, - &pd_pg0, MPI2_PHYSDISK_PGAD_FORM_GET_NEXT_PHYSDISKNUM, - phys_disk_num))) { - ioc_status = le16_to_cpu(mpi_reply.IOCStatus) & - MPI2_IOCSTATUS_MASK; - if (ioc_status == MPI2_IOCSTATUS_CONFIG_INVALID_PAGE) - break; - phys_disk_num = pd_pg0.PhysDiskNum; - handle = le16_to_cpu(pd_pg0.DevHandle); - set_bit(handle, ioc->pd_handles); + if (!ioc->is_warpdrive) { + phys_disk_num = 0xFF; + memset(ioc->pd_handles, 0, ioc->pd_handles_sz); + while (!(mpt2sas_config_get_phys_disk_pg0(ioc, &mpi_reply, + &pd_pg0, MPI2_PHYSDISK_PGAD_FORM_GET_NEXT_PHYSDISKNUM, + phys_disk_num))) { + ioc_status = le16_to_cpu(mpi_reply.IOCStatus) & + MPI2_IOCSTATUS_MASK; + if (ioc_status == MPI2_IOCSTATUS_CONFIG_INVALID_PAGE) + break; + phys_disk_num = pd_pg0.PhysDiskNum; + handle = le16_to_cpu(pd_pg0.DevHandle); + set_bit(handle, ioc->pd_handles); + } } }@@ -6243,6 +6622,50 @@ _scsih_remove_unresponding_sas_devices(s } /** + * _scsih_hide_unhide_sas_devices - add/remove device to/from OS + * @ioc: per adapter object + * + * Return nothing. + */ +static void +_scsih_hide_unhide_sas_devices(struct MPT2SAS_ADAPTER *ioc) +{ + struct _sas_device *sas_device, *sas_device_next; + + if (!ioc->is_warpdrive || ioc->mfg_pg10_hide_flag != + MFG_PAGE10_HIDE_IF_VOL_PRESENT) + return; + + if (ioc->hide_drives) { + if (_scsih_get_num_volumes(ioc)) + return; + ioc->hide_drives = 0; + list_for_each_entry_safe(sas_device, sas_device_next, + &ioc->sas_device_list, list) { + if (!mpt2sas_transport_port_add(ioc, sas_device- >handle, + sas_device->sas_address_parent)) { + _scsih_sas_device_remove(ioc, sas_device); + } else if (!sas_device->starget) { + mpt2sas_transport_port_remove(ioc, + sas_device->sas_address, + sas_device->sas_address_parent); + _scsih_sas_device_remove(ioc, sas_device); + } + } + } else { + if (!_scsih_get_num_volumes(ioc)) + return; + ioc->hide_drives = 1; + list_for_each_entry_safe(sas_device, sas_device_next, + &ioc->sas_device_list, list) { + mpt2sas_transport_port_remove(ioc, + sas_device->sas_address, + sas_device->sas_address_parent); + } + } +} + +/** * mpt2sas_scsih_reset_handler - reset callback handler (for scsih) * @ioc: per adapter object* @reset_phase: phase
mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +27
-0@@ -6326,6 +6749,7 @@ _firmware_event_work(struct work_struct spin_unlock_irqrestore(&ioc- >ioc_reset_in_progress_lock, flags); _scsih_remove_unresponding_sas_devices(ioc); + _scsih_hide_unhide_sas_devices(ioc); return; }@@ -6425,6 +6849,53 @@ mpt2sas_scsih_event_callback(struct MPT2 (Mpi2EventDataIrVolume_t *) mpi_reply->EventData); break; + case MPI2_EVENT_LOG_ENTRY_ADDED: + { + Mpi2EventDataLogEntryAdded_t *log_entry; + u32 *log_code; + + if (!ioc->is_warpdrive) + break; + + log_entry = (Mpi2EventDataLogEntryAdded_t *) + mpi_reply->EventData; + log_code = (u32 *)log_entry->LogData; + + if (le16_to_cpu(log_entry->LogEntryQualifier) + != MPT2_WARPDRIVE_LOGENTRY) + break; + + switch (le32_to_cpu(*log_code)) { + case MPT2_WARPDRIVE_LC_SSDT: + printk(MPT2SAS_WARN_FMT "WarpDrive Warning: " + "IO Throttling has occurred in the WarpDrive " + "subsystem. Check WarpDrive documentation for " + "additional details.\n", ioc->name); + break; + case MPT2_WARPDRIVE_LC_SSDLW: + printk(MPT2SAS_WARN_FMT "WarpDrive Warning: " + "Program/Erase Cycles for the WarpDrive subsystem"
+ "in degraded range. Check WarpDrive documentation
"mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +6
-0+ "for additional details.\n", ioc->name); + break; + case MPT2_WARPDRIVE_LC_SSDLF: + printk(MPT2SAS_ERR_FMT "WarpDrive Fatal Error: " + "There are no Program/Erase Cycles for the " + "WarpDrive subsystem. The storage device will be"
+ "in read-only mode. Check WarpDrive documentation
"mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +15
-1+ "for additional details.\n", ioc->name); + break; + case MPT2_WARPDRIVE_LC_BRMF: + printk(MPT2SAS_ERR_FMT "WarpDrive Fatal Error: " + "The Backup Rail Monitor has failed on the " + "WarpDrive subsystem. Check WarpDrive " + "documentation for additional details.\n", + ioc->name); + break; + } + + break; + } case MPI2_EVENT_SAS_DEVICE_STATUS_CHANGE: case MPI2_EVENT_IR_OPERATION_STATUS: case MPI2_EVENT_SAS_DISCOVERY:@@ -6583,7 +7054,8 @@ _scsih_ir_shutdown(struct MPT2SAS_ADAPTE mpi_request->Function = MPI2_FUNCTION_RAID_ACTION; mpi_request->Action = MPI2_RAID_ACTION_SYSTEM_SHUTDOWN_INITIATED; - printk(MPT2SAS_INFO_FMT "IR shutdown (sending)\n", ioc->name); + if (!ioc->hide_ir_msg) + printk(MPT2SAS_INFO_FMT "IR shutdown (sending)\n", ioc- >name); init_completion(&ioc->scsih_cmds.done); mpt2sas_base_put_smid_default(ioc, smid);wait_for_completion_timeout(&ioc->scsih_cmds.done, 10*HZ);mpt2sas_ctl.h 2011-01-19 12:13:47.568012329 renamed from mpt2sas_ctl.h 2011-01-18 11:30:28.450141059 +0530 +30
-4@@ -6597,10 +7069,11 @@ _scsih_ir_shutdown(struct MPT2SAS_ADAPTE if (ioc->scsih_cmds.status & MPT2_CMD_REPLY_VALID) { mpi_reply = ioc->scsih_cmds.reply; - printk(MPT2SAS_INFO_FMT "IR shutdown (complete): " - "ioc_status(0x%04x), loginfo(0x%08x)\n", - ioc->name, le16_to_cpu(mpi_reply->IOCStatus), - le32_to_cpu(mpi_reply->IOCLogInfo)); + if (!ioc->hide_ir_msg) + printk(MPT2SAS_INFO_FMT "IR shutdown (complete): " + "ioc_status(0x%04x), loginfo(0x%08x)\n", + ioc->name, le16_to_cpu(mpi_reply->IOCStatus), + le32_to_cpu(mpi_reply->IOCLogInfo)); } out:@@ -6759,6 +7232,9 @@ _scsih_probe_boot_devices(struct MPT2SAS spin_lock_irqsave(&ioc->sas_device_lock, flags); list_move_tail(&sas_device->list, &ioc->sas_device_list); spin_unlock_irqrestore(&ioc->sas_device_lock, flags); + + if (ioc->hide_drives) + return; if (!mpt2sas_transport_port_add(ioc, sas_device->handle, sas_device->sas_address_parent)) { _scsih_sas_device_remove(ioc, sas_device);@@ -6812,6 +7288,9 @@ _scsih_probe_sas(struct MPT2SAS_ADAPTER list_move_tail(&sas_device->list, &ioc->sas_device_list); spin_unlock_irqrestore(&ioc->sas_device_lock, flags); + if (ioc->hide_drives) + continue; + if (!mpt2sas_transport_port_add(ioc, sas_device->handle, sas_device->sas_address_parent)) { _scsih_sas_device_remove(ioc, sas_device);@@ -6882,6 +7361,11 @@ _scsih_probe(struct pci_dev *pdev, const ioc->id = mpt_ids++; sprintf(ioc->name, "%s%d", MPT2SAS_DRIVER_NAME, ioc->id); ioc->pdev = pdev; + if (id->device == MPI2_MFGPAGE_DEVID_SSS6200) { + ioc->is_warpdrive = 1; + ioc->hide_ir_msg = 1; + } else + ioc->mfg_pg10_hide_flag = MFG_PAGE10_EXPOSE_ALL_DISKS; ioc->scsi_io_cb_idx = scsi_io_cb_idx; ioc->tm_cb_idx = tm_cb_idx; ioc->ctl_cb_idx = ctl_cb_idx;@@ -6947,6 +7431,20 @@ _scsih_probe(struct pci_dev *pdev, const } ioc->wait_for_port_enable_to_complete = 0; + if (ioc->is_warpdrive) { + if (ioc->mfg_pg10_hide_flag == MFG_PAGE10_EXPOSE_ALL_DISKS) + ioc->hide_drives = 0; + else if (ioc->mfg_pg10_hide_flag == MFG_PAGE10_HIDE_ALL_DISKS) + ioc->hide_drives = 1; + else { + if (_scsih_get_num_volumes(ioc)) + ioc->hide_drives = 1; + else + ioc->hide_drives = 0; + } + } else + ioc->hide_drives = 0; + _scsih_probe_devices(ioc);return 0;--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
James,
This patch is missing for commit to your branch. I have seen you have included, below patch
http://marc.info/?l=linux-scsi&m=130019897505773&w=2
_BUT_ this patch, I have submitted earlier which is still not committed.
Anything wrong with the patch?
` Kashyap
Quoted 1,429 lines
-----Original Message-----
From: Desai, Kashyap
Sent: Thursday, March 10, 2011 6:42 PM
To: [email protected]
Cc: [email protected]; Moore, Eric; Prakash, Sathya
Subject: RE: [PATCH] mpt2sas : WarpDrive New product SSS6200 support addedJames,
Any feedback on this patch submission? I observe that this patch is not following relative depth.
It has "mpt2sas-phase8.0_wd/mpt2sas_base.c" path, so need to apply using -p1 instead of -p4.Is there any need to resend patch with correct relative depth? Please let me know I will resend in that case.
~ Kashyap
Quoted 6 lines
-----Original Message-----
From: [email protected] [mailto:linux-scsi- [email protected]] On Behalf Of Kashyap, Desai
Sent: Thursday, February 03, 2011 3:38 PM
To: [email protected]
Cc: [email protected]; Moore, Eric; Prakash,Sathya
Quoted 1 line
Subject: [PATCH] mpt2sas : WarpDrive New product SSS6200 support
added
Quoted 9 lines
Introduction
This patch has
Support for the new solid state device product SSS6200 from LSI and relavent
features w.r.t SSS6200.The major feature added in this driver is supporting Direct-I/O to
the
Quoted 3 lines
SSS6200 storage.There are some additional changes done to avoid exposing
the RAID member disks to the OS and hiding/exposing drives based onthe
Quoted 13 lines
OEM Specific Flag in Manufacturing Page10 (this is required to handle specific changes in the SSS6200 firmware).
Each and every changes are listed below.
1. Hiding IR related messages.
For SSS6200, the driver is modified not to print IR related events. Even if the debugging is enabled the IR related messages will not be displayed.
In some places if there is a need to display a message related to IR the
string "IR" is replaced with string "DD" and the string "volume" is replaced
with "direct drive". But the function names are not changed hencethere
Quoted 2 lines
are
some places where the reference to volume can be seen if debug levelis
Quoted 9 lines
set.
2. Removed RAID transport support
In Linux the user can retrieve RAID volume information from the sysfs directory.
This support is removed for SSS6200.3. Direct I/O support.
The driver tries to enable direct I/O when a volume is reported tothe
Quoted 4 lines
driver
by the firmware through IRCC events and the driver does this just before
reporting to the OS, hence all the OS issued I/O can go throughdirect
Quoted 6 lines
path
if they can, The first validation is to see whether the manufacturing page10
flag is set to expose all drives always. If that is set, the driver will not
enable direct I/O and displays the message "DDIO" is disabledglobally
Quoted 9 lines
as
drives are exposed. The driver checks whether there is more than one volume
in the controller, if so the direct I/O will be disabled globally for all
volumes in the controller and the message displayed will be "DDIO is disabled
globally as number of drives > 1.
If retrieving number of PD is failed the driver will not enabledirect
Quoted 4 lines
I/O
and displays the message Failure in computing number of drives DDIO disabled.
If memory allocation for RAIDVolumePage0 is failed, the driver willnot
Quoted 8 lines
enable
direct I/O and displays the message Memory allocation failure for RVPG0 DDIO disabled. If retrieving RAIDVolumePage0 is failed the driver will
not enable direct I/O and displays the message Failure in retrieving RVPG0 DDIO disabledIf the number of PD in a volume is greater than 8, then the direct
I/O
Quoted 6 lines
will
be disabled.
If any of individual drives handle retrieval is failed then the DD-IO will
be disabled.
If the volume is not RAID0 or if the block size is not 512 then theDD-
Quoted 3 lines
IO will
be disabled.
If the volume size is greater than 2TB then the DD-IO will bedisabled.
Quoted 8 lines
If the driver is not able to find a valid stripe exponent using the configured
stripe size then the DD-IO will be disabledWhen the DD-IO is enabled the driver will check every I/O request issued to
the storage and checks whether the request is either READ6/WRITE6/READ10/WRITE10, if it is and if the complete I/Otransfer
Quoted 10 lines
is within a stripe size then the I/O is redirected to the drive directly instead of the volume.
On completion of every I/O, if the completion is failure means if the reply
is address reply with a reply frame associated with it, then the type of I/O
will be checked, if the I/O is direct then the I/O will be retried to the volume once.Quoted 8 lines
Signed-off-by Kashyap Desai <[email protected]>Reviewed-by Eric Moore <[email protected]>Reviewed-by Sathya Prakash <[email protected]>---
diff -aurp
mpt2sas-phase8.0/mpt2sas_base.cmpt2sas-phase8.0_wd/mpt2sas_base.c
---mpt2sas-phase8.0/mpt2sas_base.c2011-01-18 11:33:41.384202609+0530
Quoted 106 lines
+++
mpt2sas-phase8.0_wd/mpt2sas_base.c2011-01-27 20:48:35.080000040
+0530mpt2sas_base.c +32
-10@@ -522,7 +522,8 @@ _base_display_event_data(struct MPT2SAS_ desc ="Device Status Change" ;break ;case MPI2_EVENT_IR_OPERATION_STATUS : - desc ="IR Operation Status" ; +if (!ioc->hide_ir_msg) + desc ="IR Operation Status" ;break ;case MPI2_EVENT_SAS_DISCOVERY : {@@ -553,16 +554,20 @@ _base_display_event_data(struct MPT2SAS_ desc ="SAS Enclosure Device Status Change" ;break ;case MPI2_EVENT_IR_VOLUME : - desc ="IR Volume" ; +if (!ioc->hide_ir_msg) + desc ="IR Volume" ;break ;case MPI2_EVENT_IR_PHYSICAL_DISK : - desc ="IR Physical Disk" ; +if (!ioc->hide_ir_msg) + desc ="IR Physical Disk" ;break ;case MPI2_EVENT_IR_CONFIGURATION_CHANGE_LIST : - desc ="IR Configuration Change List" ; +if (!ioc->hide_ir_msg) + desc ="IR Configuration Change List" ;break ;case MPI2_EVENT_LOG_ENTRY_ADDED : - desc ="Log Entry Added" ; +if (!ioc->hide_ir_msg) + desc ="Log Entry Added" ;break ; }@@ -616,7 +621,10 @@ _base_sas_log_info(struct MPT2SAS_ADAPTE originator_str ="PL" ;break ;case 2 : - originator_str ="IR" ; +if (!ioc->hide_ir_msg) + originator_str ="IR" ; +else + originator_str ="WarpDrive" ;break ; }@@ -1508,6 +1516,7 @@ mpt2sas_base_free_smid(struct MPT2SAS_AD } ioc->scsi_lookup[i].cb_idx =0xFF ; ioc->scsi_lookup[i].scmd =NULL ; + ioc->scsi_lookup[i].direct_io =0 ;list_add_tail (&ioc->scsi_lookup[i].tracker_list, &ioc->free_list);spin_unlock_irqrestore (&ioc->scsi_lookup_lock, flags);@@ -1795,10 +1804,12 @@ _base_display_ioc_capabilities(struct MPprintk ("), " );printk ("Capabilities=(" ); -if (ioc->facts.IOCCapabilities & -MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID ) { -printk ("Raid" ); - i++; +if (!ioc->hide_ir_msg) { +if (ioc->facts.IOCCapabilities & +MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID ) { +printk ("Raid" ); + i++; + } }if (ioc->facts.IOCCapabilities &MPI2_IOCFACTS_CAPABILITY_TLR ) {@@ -3631,6 +3642,7 @@ _base_make_ioc_operational(struct MPT2SAu32 reply_address;u16 smid;struct _tr_list *delayed_tr, *delayed_tr_next; +u8 hide_flag;dinitprintk (ioc,printk (MPT2SAS_INFO_FMT "%s\n" , ioc->name, __func__));@@ -3657,6 +3669,7 @@ _base_make_ioc_operational(struct MPT2SA ioc->scsi_lookup[i].cb_idx =0xFF ; ioc->scsi_lookup[i].smid = smid; ioc->scsi_lookup[i].scmd =NULL ; + ioc->scsi_lookup[i].direct_io =0 ;list_add_tail (&ioc->scsi_lookup[i].tracker_list, &ioc->free_list); }@@ -3717,6 +3730,15 @@ _base_make_ioc_operational(struct MPT2SAif (sleep_flag ==CAN_SLEEP )_base_static_config_pages (ioc); +if (ioc->wait_for_port_enable_to_complete && ioc->is_warpdrive) { +if (ioc->manu_pg10.OEMIdentifier ==0x80 ) { + hide_flag = (u8) (ioc->manu_pg10.OEMSpecificFlags0 & +MFG_PAGE10_HIDE_SSDS_MASK ); +if (hide_flag !=MFG_PAGE10_HIDE_SSDS_MASK ) + ioc->mfg_pg10_hide_flag = hide_flag; + } + } +if (ioc->wait_for_port_enable_to_complete) {if (diag_buffer_enable !=0 )mpt2sas_enable_diag_buffer (ioc, diag_buffer_enable);Quoted 3 lines
diff -aurp
mpt2sas-phase8.0/mpt2sas_base.hmpt2sas-phase8.0_wd/mpt2sas_base.h
---mpt2sas-phase8.0/mpt2sas_base.h2011-01-18 11:33:45.711139872+0530
Review line 70
Quoted 5 lines
+++
mpt2sas-phase8.0_wd/mpt2sas_base.h2011-01-27 20:57:45.016000126
+0530(quoted diff) +0
-0@@ -69,11 +69,11 @@ #define MPT2SAS_DRIVER_NAME "mpt2sas" #define MPT2SAS_AUTHOR "LSI Corporation <DL-Review line 71
Quoted 1 line
(quoted diff) +0
-0#define MPT2SAS_DESCRIPTION "LSI MPT Fusion SAS 2.0 DeviceDriver"
Quoted 52 lines
mpt2sas_base.h +15
-2-#define MPT2SAS_DRIVER_VERSION "08.100.00.00" +#define MPT2SAS_DRIVER_VERSION "08.100.00.01"#define MPT2SAS_MAJOR_VERSION 08#define MPT2SAS_MINOR_VERSION 100#define MPT2SAS_BUILD_VERSION 00 -#define MPT2SAS_RELEASE_VERSION 00 +#define MPT2SAS_RELEASE_VERSION 01/* * Set MPT2SAS_SG_DEPTH value based on user input. @@ -169,6 +169,16 @@#define MPT2SAS_INTEL_RMS2LL040_SSDID 0x350F/* +* WarpDrive Specific Log codes +*/ + +#define MPT2_WARPDRIVE_LOGENTRY (0x8002) +#define MPT2_WARPDRIVE_LC_SSDT (0x41) +#define MPT2_WARPDRIVE_LC_SSDLW (0x43) +#define MPT2_WARPDRIVE_LC_SSDLF (0x44) +#define MPT2_WARPDRIVE_LC_BRMF (0x4D) + +/* * per target private data */ #define MPT_TARGET_FLAGS_RAID_COMPONENT 0x01@@ -179,6 +189,7 @@* struct MPT2SAS_TARGET - starget private hostdata * @starget: starget object * @sas_address: target sas address +* @raid_device: raid_device pointer to access volume data * @handle: device handle * @num_luns: number luns * @flags: MPT_TARGET_FLAGS_XXX flags @@ -188,6 +199,7 @@struct MPT2SAS_TARGET {struct scsi_target *starget;u64 sas_address; +struct _raid_device *raid_device;u16 handle;int num_luns;u32 flags;@@ -195,6 +207,7 @@ struct MPT2SAS_TARGET {u8 tm_busy; }; +/* * per device private data */ mpt2sas_base.h typedef struct _MPI2_CONFIG_PAGE_MAN_10 · line 256
Quoted 2 lines
mpt2sas_base.h +0
-0@@ -242,6 +255,12 @@ typedef struct _MPI2_CONFIG_PAGE_MAN_10MPI2_POINTER PTR_MPI2_CONFIG_PAGE_MAN_10 , Mpi2ManufacturingPage10_t,MPI2_POINTER
pMpi2ManufacturingPage10_t;Quoted 19 lines
mpt2sas_base.h +7
-0+#define MFG_PAGE10_HIDE_SSDS_MASK (0x00000003) +#define MFG_PAGE10_HIDE_ALL_DISKS (0x00) +#define MFG_PAGE10_EXPOSE_ALL_DISKS (0x01) +#define MFG_PAGE10_HIDE_IF_VOL_PRESENT (0x02) + +struct MPT2SAS_DEVICE {struct MPT2SAS_TARGET *sas_target;unsigned int lun;@@ -321,6 +340,7 @@ struct _sas_device {* @sdev: scsi device struct (volumes are single lun) * @wwid: unique identifier for the volume * @handle: device handle +* @block_size: Block size of the volume * @id: target id * @channel: target channel * @volume_type: the raid level mpt2sas_base.h struct _sas_device { · line 356
Quoted 9 lines
mpt2sas_base.h +6
-0@@ -328,20 +348,33 @@ struct _sas_device {* @num_pds: number of hidden raid components * @responding: used in _scsih_raid_device_mark_responding * @percent_complete: resync percent complete +* @direct_io_enabled: Whether direct io to PDs are allowed or not +* @stripe_exponent: X where 2powX is the stripe sz in blocks +* @max_lba: Maximum number of LBA in the volume +* @stripe_sz: Stripe Size of the volume +* @device_info: Device info of the volume member disk +* @pd_handle: Array of handles of the physical drives for direct I/O
Quoted 63 lines
in le16
*/mpt2sas_base.h +16
-3+#define MPT_MAX_WARPDRIVE_PDS 8struct _raid_device {struct list_head list;struct scsi_target *starget;struct scsi_device *sdev;u64 wwid;u16 handle; +u16 block_sz;int id;int channel;u8 volume_type; -u32 device_info;u8 num_pds;u8 responding;u8 percent_complete; +u8 direct_io_enabled; +u8 stripe_exponent; +u64 max_lba; +u32 stripe_sz; +u32 device_info; +u16 pd_handle[MPT_MAX_WARPDRIVE_PDS ]; };/** @@ -450,6 +483,7 @@ struct chain_tracker {* @smid: system message id * @scmd: scsi request pointer * @cb_idx: callback index +* @direct_io: To indicate whether I/O is direct (WARPDRIVE) * @chain_list: list of chains associated to this IO * @tracker_list: list of free request (ioc->free_list) */ @@ -457,14 +491,14 @@ struct scsiio_tracker {u16 smid;struct scsi_cmnd *scmd;u8 cb_idx; +u8 direct_io;struct list_head chain_list;struct list_head tracker_list; };/** -* struct request_tracker - misc mf request tracker +* struct request_tracker - firmware request tracker * @smid: system message id -* @scmd: scsi request pointer * @cb_idx: callback index * @tracker_list: list of free request (ioc->free_list) */ @@ -812,6 +846,11 @@ struct MPT2SAS_ADAPTER {u32 diagnostic_flags[MPI2_DIAG_BUF_TYPE_COUNT ];u32 ring_buffer_offset;u32 ring_buffer_sz; +u8 is_warpdrive; +u8 hide_ir_msg; +u8 mfg_pg10_hide_flag; +u8 hide_drives; + }; typedef u8 (*MPT_CALLBACK)(struct MPT2SAS_ADAPTER *ioc, u16 smid, u8Quoted 4 lines
msix_index,
diff -aurpmpt2sas-phase8.0/mpt2sas_ctl.cmpt2sas-phase8.0_wd/mpt2sas_ctl.c
---mpt2sas-phase8.0/mpt2sas_ctl.c2011-01-18 11:30:28.453140352+0530
Quoted 14 lines
+++
mpt2sas-phase8.0_wd/mpt2sas_ctl.c2011-01-27 20:48:35.096000040
+0530mpt2sas_ctl.c +4
-1@@ -1034,7 +1034,10 @@ _ctl_getiocinfo(void __user *arg) __func__));memset (&karg,0 ,sizeof (karg)); - karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2 ; +if (ioc->is_warpdrive) + karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2_SSS6200 ; +else + karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2 ;if (ioc->pfacts) karg.port_number = ioc->pfacts[0 ].PortNumber;pci_read_config_byte (ioc->pdev,PCI_CLASS_REVISION , &revision);Quoted 3 lines
diff -aurp
mpt2sas-phase8.0/mpt2sas_ctl.hmpt2sas-phase8.0_wd/mpt2sas_ctl.h
---mpt2sas-phase8.0/mpt2sas_ctl.h2011-01-18 11:30:28.450141059+0530
Quoted 392 lines
+++
mpt2sas-phase8.0_wd/mpt2sas_ctl.h2011-01-19 12:13:47.568012329
+0530mpt2sas_ctl.h +1
-0@@ -133,6 +133,7 @@ struct mpt2_ioctl_pci_info {#define MPT2_IOCTL_INTERFACE_FC_IP (0x02)#define MPT2_IOCTL_INTERFACE_SAS (0x03)#define MPT2_IOCTL_INTERFACE_SAS2 (0x04) +#define MPT2_IOCTL_INTERFACE_SAS2_SSS6200 (0x05)#define MPT2_IOCTL_VERSION_LENGTH (32)/** diff -aurp
mpt2sas-phase8.0/mpt2sas_scsih.cmpt2sas-phase8.0_wd/mpt2sas_scsih.c
---mpt2sas-phase8.0/mpt2sas_scsih.c2011-01-18 11:33:43.225202675
+0530
+++mpt2sas-phase8.0_wd/mpt2sas_scsih.c2011-02-03 15:42:45.974149344
+0530mpt2sas_scsih.c +4
-0@@ -233,6 +233,9 @@ static struct pci_device_id scsih_pci_ta PCI_ANY_ID, PCI_ANY_ID }, { MPI2_MFGPAGE_VENDORID_LSI, MPI2_MFGPAGE_DEVID_SAS2308_3, PCI_ANY_ID, PCI_ANY_ID }, +/* SSS6200 */ + { MPI2_MFGPAGE_VENDORID_LSI, MPI2_MFGPAGE_DEVID_SSS6200, + PCI_ANY_ID, PCI_ANY_ID }, {0} /* Terminating entry */ };MODULE_DEVICE_TABLE (pci, scsih_pci_table);@@ -1256,6 +1259,7 @@ _scsih_target_alloc(struct scsi_target * sas_target_priv_data->handle = raid_device->handle; sas_target_priv_data->sas_address = raid_device- >wwid; sas_target_priv_data->flags |=MPT_TARGET_FLAGS_VOLUME ; + sas_target_priv_data->raid_device = raid_device; raid_device->starget = starget;} spin_unlock_irqrestore(&ioc->raid_device_lock, flags);mpt2sas_scsih.c +62
-1@@ -1455,7 +1459,10 @@ static int _scsih_is_raid(struct device *dev) {struct scsi_device *sdev =to_scsi_device (dev); +struct MPT2SAS_ADAPTER *ioc =shost_priv (sdev->host); +if (ioc->is_warpdrive) +return 0 ;return (sdev->channel ==RAID_CHANNEL ) ?1 :0 ; }@@ -1480,7 +1487,7 @@ _scsih_get_resync(struct device *dev) sdev->channel);spin_unlock_irqrestore (&ioc->raid_device_lock, flags); -if (!raid_device) +if (!raid_device || ioc->is_warpdrive) goto out; if (mpt2sas_config_get_raid_volume_pg0(ioc, &mpi_reply, &vol_pg0,@@ -1640,6 +1647,212 @@ _scsih_get_volume_capabilities(struct MPkfree (vol_pg0); } +/** +* _scsih_disable_ddio - Disable direct I/O for all the volumes +* @ioc: per adapter object +*/ +static void +_scsih_disable_ddio (struct MPT2SAS_ADAPTER *ioc) +{ +Mpi2RaidVolPage1_t vol_pg1; +Mpi2ConfigReply_t mpi_reply; +struct _raid_device *raid_device; +u16 handle; +u16 ioc_status; + + handle =0xFFFF ; +while (!(mpt2sas_config_get_raid_volume_pg1 (ioc, &mpi_reply, + &vol_pg1,MPI2_RAID_VOLUME_PGAD_FORM_GET_NEXT_HANDLE , handle))) { + ioc_status =le16_to_cpu (mpi_reply.IOCStatus) & +MPI2_IOCSTATUS_MASK ; +if (ioc_status ==MPI2_IOCSTATUS_CONFIG_INVALID_PAGE ) +break ; + handle =le16_to_cpu (vol_pg1.DevHandle); + raid_device =_scsih_raid_device_find_by_handle (ioc, handle); +if (raid_device) + raid_device->direct_io_enabled =0 ; + } +return ; +} + + +/** +* _scsih_get_num_volumes - Get number of volumes in the ioc +* @ioc: per adapter object +*/ +static u8 +_scsih_get_num_volumes (struct MPT2SAS_ADAPTER *ioc) +{ +Mpi2RaidVolPage1_t vol_pg1; +Mpi2ConfigReply_t mpi_reply; +u16 handle; +u8 vol_cnt =0 ; +u16 ioc_status; + + handle =0xFFFF ; +while (!(mpt2sas_config_get_raid_volume_pg1 (ioc, &mpi_reply, + &vol_pg1,MPI2_RAID_VOLUME_PGAD_FORM_GET_NEXT_HANDLE , handle))) { + ioc_status =le16_to_cpu (mpi_reply.IOCStatus) & +MPI2_IOCSTATUS_MASK ; +if (ioc_status ==MPI2_IOCSTATUS_CONFIG_INVALID_PAGE ) +break ; + vol_cnt++; + handle =le16_to_cpu (vol_pg1.DevHandle); + } +return vol_cnt; +} + + +/** +* _scsih_init_warpdrive_properties - Set properties for warpdrive direct I/O.
+ * @ioc: per adapter object
+ * @raid_device: theraid_deviceobject
+ */mpt2sas_scsih.c +20
-0+static void +_scsih_init_warpdrive_properties(struct MPT2SAS_ADAPTER *ioc, + struct _raid_device *raid_device) +{ + Mpi2RaidVolPage0_t *vol_pg0; + Mpi2RaidPhysDiskPage0_t pd_pg0; + Mpi2ConfigReply_t mpi_reply; + u16 sz; + u8 num_pds, count; + u64 mb = 1024 * 1024; + u64 tb_2 = 2 * mb * mb; + u64 capacity; + u32 stripe_sz; + u8 i, stripe_exp; + + if (!ioc->is_warpdrive) + return; + + if (ioc->mfg_pg10_hide_flag == MFG_PAGE10_EXPOSE_ALL_DISKS) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +6
-0+ "globally as drives are exposed\n", ioc->name); +return ; + } + if (_scsih_get_num_volumes(ioc) > 1) { + _scsih_disable_ddio(ioc); + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +6
-0+ "globally as number of drives > 1\n", ioc->name); +return ; + } + if ((mpt2sas_config_get_number_pds(ioc, raid_device->handle, + &num_pds)) || !num_pds) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +9
-0+ "Failure in computing number of drives\n", ioc->name); +return ; + } + + sz = offsetof(Mpi2RaidVolPage0_t , PhysDisk) + (num_pds * +sizeof (Mpi2RaidVol0PhysDisk_t)); + vol_pg0 =kzalloc (sz,GFP_KERNEL ); + if (!vol_pg0) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +6
-0+ "Memory allocation failure for RVPG0\n", ioc->name); +return ; + } + + if ((mpt2sas_config_get_raid_volume_pg0(ioc, &mpi_reply, vol_pg0, + MPI2_RAID_VOLUME_PGAD_FORM_HANDLE, raid_device->handle,sz))) {
+ printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled
"mpt2sas_scsih.c +7
-0+ "Failure in retrieving RVPG0\n", ioc->name); +kfree (vol_pg0); +return ; + } + +/* +* WARPDRIVE:If number of physical disks in a volume exceeds the max pds
mpt2sas_scsih.c +4
-0+* assumed for WARPDRIVE, disable direct I/O +*/ + if (num_pds > MPT_MAX_WARPDRIVE_PDS) { + printk(MPT2SAS_WARN_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +13
-0+"for the drive with handle(0x%04x): num_mem=%d, " +"max_mem_allowed=%d\n" , ioc->name, raid_device->handle, + num_pds, MPT_MAX_WARPDRIVE_PDS); +kfree (vol_pg0); +return ; + } + for (count = 0; count < num_pds; count++) { + if (mpt2sas_config_get_phys_disk_pg0(ioc, &mpi_reply, + &pd_pg0, MPI2_PHYSDISK_PGAD_FORM_PHYSDISKNUM, + vol_pg0->PhysDisk[count].PhysDiskNum) || + pd_pg0.DevHandle == MPT2SAS_INVALID_DEVICE_HANDLE) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is " + "disabled for the drive with handle(0x%04x)member"
mpt2sas_scsih.c +6
-0+"handle retrieval failed for member number=%d\n" , + ioc->name, raid_device->handle, + vol_pg0->PhysDisk[count].PhysDiskNum); + goto out_error; + } + raid_device->pd_handle[count] =
le16_to_cpu(pd_pg0.DevHandle);mpt2sas_scsih.c +4
-0+ } + +/* +* Assumption for WD: Direct I/O is not supported if the volume is
+ * not RAID0, if the stripe size is not 64KB, if the block size
ismpt2sas_scsih.c +5
-0+* not 512 and if the volume size is >2TB +*/ + if (raid_device->volume_type != MPI2_RAID_VOL_TYPE_RAID0 || + le16_to_cpu(vol_pg0->BlockSize) != 512) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +13
-0+"for the drive with handle(0x%04x): type=%d, " +"s_sz=%uK, blk_size=%u\n" , ioc->name, + raid_device->handle, raid_device->volume_type, +le32_to_cpu (vol_pg0->StripeSize)/2 , + le16_to_cpu(vol_pg0->BlockSize)); + goto out_error; + } + + capacity = (u64 )le16_to_cpu (vol_pg0->BlockSize) * + (le64_to_cpu (vol_pg0->MaxLBA) +1 ); + + if (capacity > tb_2) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +15
-0+"for the drive with handle(0x%04x) since drive sz > 2TB\n" , + ioc->name, raid_device->handle); + goto out_error; + } + + stripe_sz =le32_to_cpu (vol_pg0->StripeSize); + stripe_exp =0 ; +for (i =0 ; i <32 ; i++) { +if (stripe_sz &1 ) +break ; + stripe_exp++; + stripe_sz >>=1 ; + } + if (i == 32) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
+ "for the drive with handle(0x%04x) invalid stripe sz
%uK\n",mpt2sas_scsih.c +8
-0+ ioc->name, raid_device->handle, + le32_to_cpu(vol_pg0->StripeSize)/2); + goto out_error; + } + raid_device->stripe_exponent = stripe_exp; + raid_device->direct_io_enabled =1 ; + + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is Enabled for thedrive"
mpt2sas_scsih.c +3
-0+ " with handle(0x%04x)\n", ioc->name, raid_device->handle); +/* +* WARPDRIVE: Though the following fields are not used for direct IO,
mpt2sas_scsih.c +30
-6+* stored for future purpose: +*/ + raid_device->max_lba =le64_to_cpu (vol_pg0->MaxLBA); + raid_device->stripe_sz =le32_to_cpu (vol_pg0->StripeSize); + raid_device->block_sz =le16_to_cpu (vol_pg0->BlockSize); + + +kfree (vol_pg0); +return ; + +out_error: + raid_device->direct_io_enabled =0 ; +for (count =0 ; count < num_pds; count++) + raid_device->pd_handle[count] =0 ; +kfree (vol_pg0); +return ; +}/** * _scsih_enable_tlr - setting TLR flags @@ -1710,6 +1923,11 @@ _scsih_slave_configure(struct scsi_devic_scsih_get_volume_capabilities (ioc, raid_device); +/* +* WARPDRIVE: Initialize the required data for Direct IO +*/ +_scsih_init_warpdrive_properties (ioc, raid_device); +/* RAID Queue Depth Support * IS volume = underlying qdepth of drive type, either * MPT2SAS_SAS_QUEUE_DEPTH or MPT2SAS_SATA_QUEUE_DEPTH @@ -1757,14 +1975,16 @@ _scsih_slave_configure(struct scsi_devicbreak ; } -sdev_printk (KERN_INFO , sdev,"%s: " - "handle(0x%04x), wwid(0x%016llx), pd_count(%d), type(%s)\n", - r_level, raid_device->handle, - (unsigned long long )raid_device->wwid, - raid_device->num_pds, ds); + if (!ioc->hide_ir_msg) + sdev_printk(KERN_INFO, sdev, "%s: handle(0x%04x), " +"wwid(0x%016llx), pd_count(%d), type(%s)\n" , + r_level, raid_device->handle, + (unsigned long long )raid_device->wwid, + raid_device->num_pds, ds);_scsih_change_queue_depth (sdev, qdepth,SCSI_QDEPTH_DEFAULT );/* raid transport support */ -_scsih_set_level (sdev, raid_device); +if (!ioc->is_warpdrive) +_scsih_set_level (sdev, raid_device);return 0 ;}mpt2sas_scsih.c +5
-1@@ -2182,16 +2402,20 @@ _scsih_tm_display_info(struct MPT2SAS_ADstruct MPT2SAS_TARGET *priv_target = starget->hostdata;struct _sas_device *sas_device =NULL ;unsigned long flags; +char *device_str =NULL ;if (!priv_target)return ; +if (ioc->hide_ir_msg) + device_str ="WarpDrive" ; +else + device_str ="volume" ;scsi_print_command (scmd);if (priv_target->flags &MPT_TARGET_FLAGS_VOLUME ) { - starget_printk(KERN_INFO, starget, "volume handle(0x%04x),"
mpt2sas_scsih.c +2
-3-"volume wwid(0x%016llx)\n" , - priv_target->handle, - (unsigned long long)priv_target->sas_address); + starget_printk(KERN_INFO, starget, "%s handle(0x%04x), " + "%s wwid(0x%016llx)\n", device_str, priv_target-Quoted 1 line
handle,
+
device_str, (unsigned long long)priv_target-Quoted 1 line
sas_address);} else { spin_lock_irqsave(&ioc->sas_device_lock, flags); sas_device =mpt2sas_scsih_sas_device_find_by_sas_address(ioc,
mpt2sas_scsih.c +3
-0@@ -3130,6 +3354,9 @@ _scsih_check_ir_config_unhide_events(str a =0 ; b =0 ; +if (ioc->is_warpdrive) +return ; +/* Volume Resets for Deleted or Removed */ element = (Mpi2EventIrConfigElement_t *)&event_data- >ConfigElement[0];for (i = 0; i < event_data->NumElements; i++, element++) {mpt2sas_scsih.c +20
-0@@ -3347,6 +3574,105 @@ _scsih_eedp_error_handling(struct scsi_c }/** +* _scsih_scsi_direct_io_get - returns direct io flag +* @ioc: per adapter object +* @smid: system request message index +* +* Returns the smid stored scmd pointer. +*/ +static inline u8 +_scsih_scsi_direct_io_get (struct MPT2SAS_ADAPTER *ioc,u16 smid) +{ +return ioc->scsi_lookup[smid -1 ].direct_io; +} + +/** +* _scsih_scsi_direct_io_set - sets direct io flag +* @ioc: per adapter object +* @smid: system request message index +* @direct_io: Zero or non-zero value to set in the direct_io flag +* +* Returns Nothing. +*/ mpt2sas_scsih.c _scsih_eedp_error_handling(struct scsi_c · line 3606
Quoted 10 lines
mpt2sas_scsih.c +9
-0+static inline void +_scsih_scsi_direct_io_set (struct MPT2SAS_ADAPTER *ioc,u16 smid,u8 direct_io) +{ + ioc->scsi_lookup[smid -1 ].direct_io = direct_io; +} + + +/** +* _scsih_setup_direct_io - setup MPI request for WARPDRIVE Direct I/O
Quoted 591 lines
mpt2sas_scsih.c +26
-0+* @ioc: per adapter object +* @scmd: pointer to scsi command object +* @raid_device: pointer to raid device data structure +* @mpi_request: pointer to the SCSI_IO reqest message frame +* @smid: system request message index +* +* Returns nothing +*/ +static void +_scsih_setup_direct_io (struct MPT2SAS_ADAPTER *ioc,struct scsi_cmnd *scmd, +struct _raid_device *raid_device,Mpi2SCSIIORequest_t *mpi_request, +u16 smid) +{ +u32 v_lba, p_lba, stripe_off, stripe_unit, column, io_size; +u32 stripe_sz, stripe_exp; +u8 num_pds, *cdb_ptr, *tmp_ptr, *lba_ptr1, *lba_ptr2; +u8 cdb0 = scmd->cmnd[0 ]; + +/* +* Try Direct I/O to RAID memeber disks +*/ +if (cdb0 ==READ_16 || cdb0 ==READ_10 || + cdb0 ==WRITE_16 || cdb0 ==WRITE_10 ) { + cdb_ptr = mpi_request->CDB.CDB32; + + if ((cdb0 < READ_16) || !(cdb_ptr[2] | cdb_ptr[3] |cdb_ptr[4]
mpt2sas_scsih.c +4
-0+ | cdb_ptr[5])) { + io_size =scsi_bufflen (scmd) >>9 ; +/* get virtual lba */ + lba_ptr1 = lba_ptr2 = (cdb0 < READ_16) ? &cdb_ptr[2]:
mpt2sas_scsih.c +43
-2+ &cdb_ptr[6 ]; + tmp_ptr = (u8 *)&v_lba +3 ; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr = *lba_ptr1; + +if (((u64 )v_lba + (u64 )io_size -1 ) <= + (u32 )raid_device->max_lba) { + stripe_sz = raid_device->stripe_sz; + stripe_exp = raid_device->stripe_exponent; + stripe_off = v_lba & (stripe_sz -1 ); + +/* Check whether IO falls within a stripe */ +if ((stripe_off + io_size) <= stripe_sz) { + num_pds = raid_device->num_pds; + p_lba = v_lba >> stripe_exp; + stripe_unit = p_lba / num_pds; + column = p_lba % num_pds; + p_lba = (stripe_unit << stripe_exp) + + stripe_off; + mpi_request->DevHandle = +cpu_to_le16 (raid_device-> + pd_handle[column]); + tmp_ptr = (u8 *)&p_lba +3 ; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2 = *tmp_ptr; +/* +* WD: To indicate this I/O is directI/O +*/ +_scsih_scsi_direct_io_set (ioc, smid,1 ); + } + } + } + } +} + +/** * _scsih_qcmd - main scsi request entry point * @scmd: pointer to scsi command object * @done: function pointer to be invoked on completion @@ -3363,6 +3689,7 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd,struct MPT2SAS_ADAPTER *ioc =shost_priv (scmd->device->host);struct MPT2SAS_DEVICE *sas_device_priv_data;struct MPT2SAS_TARGET *sas_target_priv_data; +struct _raid_device *raid_device;Mpi2SCSIIORequest_t *mpi_request;u32 mpi_control;u16 smid;@@ -3424,8 +3751,10 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd, }else mpi_control |=MPI2_SCSIIO_CONTROL_SIMPLEQ ; -/* Make sure Device is not raid volume */ - if (!_scsih_is_raid(&scmd->device->sdev_gendev) && +/* Make sure Device is not raid volume. +* We do not expose raid functionality to upper layer for warpdrive.
(quoted diff) +2
-0+ */ + if (!ioc->is_warpdrive && _scsih_is_raid(&scmd->device-Quoted 1 line
sdev_gendev) &&sas_is_tlr_enabled(scmd->device) && scmd->cmd_len != 32) mpi_control |= MPI2_SCSIIO_CONTROL_TLR_ON;mpt2sas_scsih.c +6
-1@@ -3473,9 +3802,14 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd, } } + raid_device = sas_target_priv_data->raid_device; +if (raid_device && raid_device->direct_io_enabled) +_scsih_setup_direct_io (ioc, scmd, raid_device, mpi_request, + smid); +if (likely (mpi_request->Function ==MPI2_FUNCTION_SCSI_IO_REQUEST ))mpt2sas_base_put_smid_scsi_io (ioc, smid, - sas_device_priv_data->sas_target->handle); +le16_to_cpu (mpi_request->DevHandle));else mpt2sas_base_put_smid_default (ioc, smid);return 0;mpt2sas_scsih.c +8
-2@@ -3540,10 +3874,16 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAPunsigned long flags;struct scsi_target *starget = scmd->device->sdev_target;struct MPT2SAS_TARGET *priv_target = starget->hostdata; +char *device_str =NULL ;if (!priv_target)return ; +if (ioc->hide_ir_msg) + device_str ="WarpDrive" ; +else + device_str ="volume" ; +if (log_info ==0x31170000 )return ;@@ -3660,8 +4000,8 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAPscsi_print_command (scmd);if (priv_target->flags &MPT_TARGET_FLAGS_VOLUME ) { -printk (MPT2SAS_WARN_FMT "\tvolume wwid(0x%016llx)\n" , ioc- >name, - (unsigned long long )priv_target->sas_address); +printk (MPT2SAS_WARN_FMT "\t%s wwid(0x%016llx)\n" , ioc- >name, + device_str, (unsigned long long )priv_target- >sas_address);} else { spin_lock_irqsave(&ioc->sas_device_lock, flags); sas_device =mpt2sas_scsih_sas_device_find_by_sas_address(ioc,
mpt2sas_scsih.c +16
-1@@ -3840,6 +4180,20 @@ _scsih_io_done(struct MPT2SAS_ADAPTER *i scmd->result =DID_NO_CONNECT <<16 ; goto out; } +/* +* WARPDRIVE: If direct_io is set then it is directIO, +* the failed direct I/O should be redirected to volume +*/ +if (_scsih_scsi_direct_io_get (ioc, smid)) { +_scsih_scsi_direct_io_set (ioc, smid,0 ); +memcpy (mpi_request->CDB.CDB32, scmd->cmnd, scmd->cmd_len); + mpi_request->DevHandle = +cpu_to_le16 (sas_device_priv_data->sas_target->handle); +mpt2sas_base_put_smid_scsi_io (ioc, smid, + sas_device_priv_data->sas_target->handle); +return 0 ; + } +/* turning off TLR */ scsi_state = mpi_reply->SCSIState;@@ -3848,7 +4202,10 @@ _scsih_io_done(struct MPT2SAS_ADAPTER *ile32_to_cpu (mpi_reply->ResponseInfo) &0xFF ;if (!sas_device_priv_data->tlr_snoop_check) { sas_device_priv_data->tlr_snoop_check++; - if (!_scsih_is_raid(&scmd->device->sdev_gendev) && +/* Make sure Device is not raid volume. +* We do not expose raid functionality to upper layer for warpdrive.
(quoted diff) +2
-0+ */ + if (!ioc->is_warpdrive && !_scsih_is_raid(&scmd->device-Quoted 1 line
sdev_gendev) &&sas_is_tlr_enabled(scmd->device) && response_code == MPI2_SCSITASKMGMT_RSP_INVALID_FRAME) { sas_disable_tlr(scmd->device);mpt2sas_scsih.c +7
-3@@ -4681,8 +5038,10 @@ _scsih_remove_device(struct MPT2SAS_ADAP_scsih_ublock_io_device (ioc, sas_device_backup.handle); -mpt2sas_transport_port_remove (ioc, sas_device_backup.sas_address, - sas_device_backup.sas_address_parent); +if (!ioc->hide_drives) +mpt2sas_transport_port_remove (ioc, + sas_device_backup.sas_address, + sas_device_backup.sas_address_parent); printk(MPT2SAS_INFO_FMT "removing handle(0x%04x), sas_addr" "(0x%016llx)\n", ioc->name, sas_device_backup.handle,@@ -5413,6 +5772,7 @@ _scsih_sas_pd_hide(struct MPT2SAS_ADAPTE &sas_device->volume_wwid);set_bit (handle, ioc->pd_handles);_scsih_reprobe_target (sas_device->starget,1 ); + }/** @@ -5591,7 +5951,8 @@ _scsih_sas_ir_config_change_event(structMpi2EventDataIrConfigChangeList_t *event_data = fw_event- >event_data;#ifdef CONFIG_SCSI_MPT2SAS_LOGGING -if (ioc->logging_level &MPT_DEBUG_EVENT_WORK_TASK ) +if ((ioc->logging_level &MPT_DEBUG_EVENT_WORK_TASK ) + && !ioc->hide_ir_msg)_scsih_sas_ir_config_change_event_debug (ioc, event_data);#endif
mpt2sas_scsih.c +10
-7@@ -5614,16 +5975,20 @@ _scsih_sas_ir_config_change_event(struct le16_to_cpu(element->VolDevHandle));break ;case MPI2_EVENT_IR_CHANGE_RC_PD_CREATED : -_scsih_sas_pd_hide (ioc, element); +if (!ioc->is_warpdrive) +_scsih_sas_pd_hide (ioc, element);break ;case MPI2_EVENT_IR_CHANGE_RC_PD_DELETED : -_scsih_sas_pd_expose (ioc, element); +if (!ioc->is_warpdrive) +_scsih_sas_pd_expose (ioc, element);break ;case MPI2_EVENT_IR_CHANGE_RC_HIDE : -_scsih_sas_pd_add (ioc, element); +if (!ioc->is_warpdrive) +_scsih_sas_pd_add (ioc, element);break ;case MPI2_EVENT_IR_CHANGE_RC_UNHIDE : -_scsih_sas_pd_delete (ioc, element); +if (!ioc->is_warpdrive) +_scsih_sas_pd_delete (ioc, element);break ; } }@@ -5654,9 +6019,10 @@ _scsih_sas_ir_volume_event(struct MPT2SA handle =le16_to_cpu (event_data->VolDevHandle); state =le32_to_cpu (event_data->NewValue); -dewtprintk (ioc,printk (MPT2SAS_INFO_FMT "%s: handle(0x%04x), " -"old(0x%08x), new(0x%08x)\n" , ioc->name, __func__, handle, -le32_to_cpu (event_data->PreviousValue), state)); + if (!ioc->hide_ir_msg) + dewtprintk(ioc, printk(MPT2SAS_INFO_FMT "%s:handle(0x%04x), "
+ "old(0x%08x), new(0x%08x)\n",ioc->name,__func__,
handle,mpt2sas_scsih.c +3
-3+ le32_to_cpu(event_data->PreviousValue), state));switch (state) {case MPI2_RAID_VOL_STATE_MISSING :@@ -5736,9 +6102,10 @@ _scsih_sas_ir_physical_disk_event(struct handle =le16_to_cpu (event_data->PhysDiskDevHandle); state =le32_to_cpu (event_data->NewValue); -dewtprintk (ioc,printk (MPT2SAS_INFO_FMT "%s: handle(0x%04x), " -"old(0x%08x), new(0x%08x)\n" , ioc->name, __func__, handle, -le32_to_cpu (event_data->PreviousValue), state)); + if (!ioc->hide_ir_msg) + dewtprintk(ioc, printk(MPT2SAS_INFO_FMT "%s:handle(0x%04x), "
+ "old(0x%08x), new(0x%08x)\n",ioc->name,__func__,
handle,mpt2sas_scsih.c +6
-3+ le32_to_cpu(event_data->PreviousValue), state));switch (state) {case MPI2_RAID_PD_STATE_ONLINE :@@ -5747,7 +6114,8 @@ _scsih_sas_ir_physical_disk_event(structcase MPI2_RAID_PD_STATE_OPTIMAL :case MPI2_RAID_PD_STATE_HOT_SPARE : -set_bit (handle, ioc->pd_handles); +if (!ioc->is_warpdrive) +set_bit (handle, ioc->pd_handles);spin_lock_irqsave (&ioc->sas_device_lock, flags); sas_device =_scsih_sas_device_find_by_handle (ioc, handle);@@ -5851,7 +6219,8 @@ _scsih_sas_ir_operation_status_event(stru16 handle;#ifdef CONFIG_SCSI_MPT2SAS_LOGGING -if (ioc->logging_level &MPT_DEBUG_EVENT_WORK_TASK ) +if ((ioc->logging_level &MPT_DEBUG_EVENT_WORK_TASK ) + && !ioc->hide_ir_msg)_scsih_sas_ir_operation_status_event_debug (ioc, event_data);#endif @@ -5910,7 +6279,7 @@ static void _scsih_mark_responding_sas_device(struct MPT2SAS_ADAPTER *ioc, u64 sas_address, u16 slot, u16 handle) { - struct MPT2SAS_TARGET *sas_target_priv_data; + struct MPT2SAS_TARGET *sas_target_priv_data = NULL;struct scsi_target *starget;struct _sas_device *sas_device;unsigned long flags;mpt2sas_scsih.c +10
-8@@ -5918,7 +6287,7 @@ _scsih_mark_responding_sas_device(structspin_lock_irqsave (&ioc->sas_device_lock, flags);list_for_each_entry (sas_device, &ioc->sas_device_list, list) {if (sas_device->sas_address == sas_address && - sas_device->slot == slot && sas_device->starget) { + sas_device->slot == slot) { sas_device->responding =1 ; starget = sas_device->starget;if (starget && starget->hostdata) {@@ -5927,13 +6296,15 @@ _scsih_mark_responding_sas_device(struct sas_target_priv_data->deleted =0 ; }else sas_target_priv_data =NULL ; -starget_printk (KERN_INFO , sas_device->starget, -"handle(0x%04x), sas_addr(0x%016llx), enclosure " -"logical id(0x%016llx), slot(%d)\n" , handle, - (unsigned long long )sas_device->sas_address, - (unsigned long long ) - sas_device->enclosure_logical_id, - sas_device->slot); +if (starget) +starget_printk (KERN_INFO , starget, +"handle(0x%04x), sas_addr(0x%016llx), " +"enclosure logical id(0x%016llx), " +"slot(%d)\n" , handle, + (unsigned long long )sas_device- >sas_address, + (unsigned long long ) + sas_device->enclosure_logical_id, + sas_device->slot);if (sas_device->handle == handle) goto out;printk(KERN_INFO "\thandle changed
from(0x%04x)!!!\n",mpt2sas_scsih.c +2
-0@@ -6025,6 +6396,12 @@ _scsih_mark_responding_raid_device(strucstarget_printk (KERN_INFO , raid_device->starget,"handle(0x%04x), wwid(0x%016llx)\n" , handle, (unsigned long long )raid_device->wwid); +/* +* WARPDRIVE: The handles of the PDs might have changed
mpt2sas_scsih.c +4
-0+* across the host reset so re-initialize the +* required data for Direct IO +*/ +_scsih_init_warpdrive_properties (ioc, raid_device);if (raid_device->handle == handle) goto out; printk(KERN_INFO "\thandle changedfrom(0x%04x)!!!\n",
mpt2sas_scsih.c +58
-12@@ -6086,18 +6463,20 @@ _scsih_search_responding_raid_devices(st }/* refresh the pd_handles */ - phys_disk_num =0xFF ; -memset (ioc->pd_handles,0 , ioc->pd_handles_sz); -while (!(mpt2sas_config_get_phys_disk_pg0 (ioc, &mpi_reply, - &pd_pg0,MPI2_PHYSDISK_PGAD_FORM_GET_NEXT_PHYSDISKNUM , - phys_disk_num))) { - ioc_status =le16_to_cpu (mpi_reply.IOCStatus) & -MPI2_IOCSTATUS_MASK ; -if (ioc_status ==MPI2_IOCSTATUS_CONFIG_INVALID_PAGE ) -break ; - phys_disk_num = pd_pg0.PhysDiskNum; - handle =le16_to_cpu (pd_pg0.DevHandle); -set_bit (handle, ioc->pd_handles); +if (!ioc->is_warpdrive) { + phys_disk_num =0xFF ; +memset (ioc->pd_handles,0 , ioc->pd_handles_sz); +while (!(mpt2sas_config_get_phys_disk_pg0 (ioc, &mpi_reply, + &pd_pg0,MPI2_PHYSDISK_PGAD_FORM_GET_NEXT_PHYSDISKNUM , + phys_disk_num))) { + ioc_status =le16_to_cpu (mpi_reply.IOCStatus) & +MPI2_IOCSTATUS_MASK ; +if (ioc_status ==MPI2_IOCSTATUS_CONFIG_INVALID_PAGE ) +break ; + phys_disk_num = pd_pg0.PhysDiskNum; + handle =le16_to_cpu (pd_pg0.DevHandle); +set_bit (handle, ioc->pd_handles); + } } }@@ -6243,6 +6622,50 @@ _scsih_remove_unresponding_sas_devices(s }/** +* _scsih_hide_unhide_sas_devices - add/remove device to/from OS +* @ioc: per adapter object +* +* Return nothing. +*/ +static void +_scsih_hide_unhide_sas_devices (struct MPT2SAS_ADAPTER *ioc) +{ +struct _sas_device *sas_device, *sas_device_next; + +if (!ioc->is_warpdrive || ioc->mfg_pg10_hide_flag != +MFG_PAGE10_HIDE_IF_VOL_PRESENT ) +return ; + +if (ioc->hide_drives) { +if (_scsih_get_num_volumes (ioc)) +return ; + ioc->hide_drives =0 ; +list_for_each_entry_safe (sas_device, sas_device_next, + &ioc->sas_device_list, list) { +if (!mpt2sas_transport_port_add (ioc, sas_device- >handle, + sas_device->sas_address_parent)) { +_scsih_sas_device_remove (ioc, sas_device); + }else if (!sas_device->starget) { +mpt2sas_transport_port_remove (ioc, + sas_device->sas_address, + sas_device->sas_address_parent); +_scsih_sas_device_remove (ioc, sas_device); + } + } + }else { +if (!_scsih_get_num_volumes (ioc)) +return ; + ioc->hide_drives =1 ; +list_for_each_entry_safe (sas_device, sas_device_next, + &ioc->sas_device_list, list) { +mpt2sas_transport_port_remove (ioc, + sas_device->sas_address, + sas_device->sas_address_parent); + } + } +} + +/** * mpt2sas_scsih_reset_handler - reset callback handler (for scsih) * @ioc: per adapter object * @reset_phase: phase
mpt2sas_scsih.c +27
-0@@ -6326,6 +6749,7 @@ _firmware_event_work(struct work_structspin_unlock_irqrestore (&ioc- >ioc_reset_in_progress_lock, flags);_scsih_remove_unresponding_sas_devices (ioc); +_scsih_hide_unhide_sas_devices (ioc);return ; }@@ -6425,6 +6849,53 @@ mpt2sas_scsih_event_callback(struct MPT2 (Mpi2EventDataIrVolume_t *) mpi_reply->EventData);break ; +case MPI2_EVENT_LOG_ENTRY_ADDED : + { + Mpi2EventDataLogEntryAdded_t *log_entry; + u32 *log_code; + + if (!ioc->is_warpdrive) + break; + + log_entry = (Mpi2EventDataLogEntryAdded_t *) + mpi_reply->EventData; + log_code = (u32 *)log_entry->LogData; + + if (le16_to_cpu(log_entry->LogEntryQualifier) + != MPT2_WARPDRIVE_LOGENTRY) + break; + + switch (le32_to_cpu(*log_code)) { + case MPT2_WARPDRIVE_LC_SSDT: + printk(MPT2SAS_WARN_FMT "WarpDrive Warning: " + "IO Throttling has occurred in the WarpDrive " + "subsystem. Check WarpDrive documentation for " + "additional details.\n", ioc->name); + break; + case MPT2_WARPDRIVE_LC_SSDLW: + printk(MPT2SAS_WARN_FMT "WarpDrive Warning: " + "Program/Erase Cycles for the WarpDrive subsystem"
+ "in degraded range. Check WarpDrive documentation
"mpt2sas_scsih.c +6
-0+ "for additional details.\n", ioc->name); +break ; +case MPT2_WARPDRIVE_LC_SSDLF : +printk (MPT2SAS_ERR_FMT "WarpDrive Fatal Error: " +"There are no Program/Erase Cycles for the " + "WarpDrive subsystem. The storage device will be"
+ "in read-only mode. Check WarpDrive documentation
"mpt2sas_scsih.c +15
-1+ "for additional details.\n", ioc->name); +break ; +case MPT2_WARPDRIVE_LC_BRMF : +printk (MPT2SAS_ERR_FMT "WarpDrive Fatal Error: " +"The Backup Rail Monitor has failed on the " +"WarpDrive subsystem. Check WarpDrive " +"documentation for additional details.\n" , + ioc->name); +break ; + } + +break ; + }case MPI2_EVENT_SAS_DEVICE_STATUS_CHANGE :case MPI2_EVENT_IR_OPERATION_STATUS :case MPI2_EVENT_SAS_DISCOVERY :@@ -6583,7 +7054,8 @@ _scsih_ir_shutdown(struct MPT2SAS_ADAPTE mpi_request->Function =MPI2_FUNCTION_RAID_ACTION ; mpi_request->Action =MPI2_RAID_ACTION_SYSTEM_SHUTDOWN_INITIATED ; -printk (MPT2SAS_INFO_FMT "IR shutdown (sending)\n" , ioc->name); +if (!ioc->hide_ir_msg) +printk (MPT2SAS_INFO_FMT "IR shutdown (sending)\n" , ioc- >name);init_completion (&ioc->scsih_cmds.done);mpt2sas_base_put_smid_default (ioc, smid);wait_for_completion_timeout(&ioc->scsih_cmds.done, 10*HZ);mpt2sas_scsih.c +30
-4@@ -6597,10 +7069,11 @@ _scsih_ir_shutdown(struct MPT2SAS_ADAPTEif (ioc->scsih_cmds.status &MPT2_CMD_REPLY_VALID ) { mpi_reply = ioc->scsih_cmds.reply; -printk (MPT2SAS_INFO_FMT "IR shutdown (complete): " -"ioc_status(0x%04x), loginfo(0x%08x)\n" , - ioc->name,le16_to_cpu (mpi_reply->IOCStatus), -le32_to_cpu (mpi_reply->IOCLogInfo)); +if (!ioc->hide_ir_msg) +printk (MPT2SAS_INFO_FMT "IR shutdown (complete): " +"ioc_status(0x%04x), loginfo(0x%08x)\n" , + ioc->name,le16_to_cpu (mpi_reply->IOCStatus), +le32_to_cpu (mpi_reply->IOCLogInfo)); } out:@@ -6759,6 +7232,9 @@ _scsih_probe_boot_devices(struct MPT2SASspin_lock_irqsave (&ioc->sas_device_lock, flags);list_move_tail (&sas_device->list, &ioc->sas_device_list);spin_unlock_irqrestore (&ioc->sas_device_lock, flags); + +if (ioc->hide_drives) +return ;if (!mpt2sas_transport_port_add (ioc, sas_device->handle, sas_device->sas_address_parent)) {_scsih_sas_device_remove (ioc, sas_device);@@ -6812,6 +7288,9 @@ _scsih_probe_sas(struct MPT2SAS_ADAPTERlist_move_tail (&sas_device->list, &ioc->sas_device_list);spin_unlock_irqrestore (&ioc->sas_device_lock, flags); +if (ioc->hide_drives) +continue ; +if (!mpt2sas_transport_port_add (ioc, sas_device->handle, sas_device->sas_address_parent)) {_scsih_sas_device_remove (ioc, sas_device);@@ -6882,6 +7361,11 @@ _scsih_probe(struct pci_dev *pdev, const ioc->id = mpt_ids++;sprintf (ioc->name,"%s%d" ,MPT2SAS_DRIVER_NAME , ioc->id); ioc->pdev = pdev; +if (id->device ==MPI2_MFGPAGE_DEVID_SSS6200 ) { + ioc->is_warpdrive =1 ; + ioc->hide_ir_msg =1 ; + }else + ioc->mfg_pg10_hide_flag =MFG_PAGE10_EXPOSE_ALL_DISKS ; ioc->scsi_io_cb_idx = scsi_io_cb_idx; ioc->tm_cb_idx = tm_cb_idx; ioc->ctl_cb_idx = ctl_cb_idx;@@ -6947,6 +7431,20 @@ _scsih_probe(struct pci_dev *pdev, const } ioc->wait_for_port_enable_to_complete =0 ; +if (ioc->is_warpdrive) { +if (ioc->mfg_pg10_hide_flag ==MFG_PAGE10_EXPOSE_ALL_DISKS ) + ioc->hide_drives =0 ; +else if (ioc->mfg_pg10_hide_flag ==MFG_PAGE10_HIDE_ALL_DISKS ) + ioc->hide_drives =1 ; +else { +if (_scsih_get_num_volumes (ioc)) + ioc->hide_drives =1 ; +else + ioc->hide_drives =0 ; + } + }else + ioc->hide_drives =0 ; +_scsih_probe_devices (ioc);return 0;--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
James,
Can I have your feedback for this particular patch?
~ Kashyap
Quoted 1,429 lines
-----Original Message-----
From: Desai, Kashyap
Sent: Thursday, March 10, 2011 6:42 PM
To: [email protected]
Cc: [email protected]; Moore, Eric; Prakash, Sathya
Subject: RE: [PATCH] mpt2sas : WarpDrive New product SSS6200 support addedJames,
Any feedback on this patch submission? I observe that this patch is not following relative depth.
It has "mpt2sas-phase8.0_wd/mpt2sas_base.c" path, so need to apply using -p1 instead of -p4.Is there any need to resend patch with correct relative depth? Please let me know I will resend in that case.
~ Kashyap
Quoted 6 lines
-----Original Message-----
From: [email protected] [mailto:linux-scsi- [email protected]] On Behalf Of Kashyap, Desai
Sent: Thursday, February 03, 2011 3:38 PM
To: [email protected]
Cc: [email protected]; Moore, Eric; Prakash,Sathya
Quoted 1 line
Subject: [PATCH] mpt2sas : WarpDrive New product SSS6200 support
added
Quoted 9 lines
Introduction
This patch has
Support for the new solid state device product SSS6200 from LSI and relavent
features w.r.t SSS6200.The major feature added in this driver is supporting Direct-I/O to
the
Quoted 3 lines
SSS6200 storage.There are some additional changes done to avoid exposing
the RAID member disks to the OS and hiding/exposing drives based onthe
Quoted 13 lines
OEM Specific Flag in Manufacturing Page10 (this is required to handle specific changes in the SSS6200 firmware).
Each and every changes are listed below.
1. Hiding IR related messages.
For SSS6200, the driver is modified not to print IR related events. Even if the debugging is enabled the IR related messages will not be displayed.
In some places if there is a need to display a message related to IR the
string "IR" is replaced with string "DD" and the string "volume" is replaced
with "direct drive". But the function names are not changed hencethere
Quoted 2 lines
are
some places where the reference to volume can be seen if debug levelis
Quoted 9 lines
set.
2. Removed RAID transport support
In Linux the user can retrieve RAID volume information from the sysfs directory.
This support is removed for SSS6200.3. Direct I/O support.
The driver tries to enable direct I/O when a volume is reported tothe
Quoted 4 lines
driver
by the firmware through IRCC events and the driver does this just before
reporting to the OS, hence all the OS issued I/O can go throughdirect
Quoted 6 lines
path
if they can, The first validation is to see whether the manufacturing page10
flag is set to expose all drives always. If that is set, the driver will not
enable direct I/O and displays the message "DDIO" is disabledglobally
Quoted 9 lines
as
drives are exposed. The driver checks whether there is more than one volume
in the controller, if so the direct I/O will be disabled globally for all
volumes in the controller and the message displayed will be "DDIO is disabled
globally as number of drives > 1.
If retrieving number of PD is failed the driver will not enabledirect
Quoted 4 lines
I/O
and displays the message Failure in computing number of drives DDIO disabled.
If memory allocation for RAIDVolumePage0 is failed, the driver willnot
Quoted 8 lines
enable
direct I/O and displays the message Memory allocation failure for RVPG0 DDIO disabled. If retrieving RAIDVolumePage0 is failed the driver will
not enable direct I/O and displays the message Failure in retrieving RVPG0 DDIO disabledIf the number of PD in a volume is greater than 8, then the direct
I/O
Quoted 6 lines
will
be disabled.
If any of individual drives handle retrieval is failed then the DD-IO will
be disabled.
If the volume is not RAID0 or if the block size is not 512 then theDD-
Quoted 3 lines
IO will
be disabled.
If the volume size is greater than 2TB then the DD-IO will bedisabled.
Quoted 8 lines
If the driver is not able to find a valid stripe exponent using the configured
stripe size then the DD-IO will be disabledWhen the DD-IO is enabled the driver will check every I/O request issued to
the storage and checks whether the request is either READ6/WRITE6/READ10/WRITE10, if it is and if the complete I/Otransfer
Quoted 10 lines
is within a stripe size then the I/O is redirected to the drive directly instead of the volume.
On completion of every I/O, if the completion is failure means if the reply
is address reply with a reply frame associated with it, then the type of I/O
will be checked, if the I/O is direct then the I/O will be retried to the volume once.Quoted 8 lines
Signed-off-by Kashyap Desai <[email protected]>Reviewed-by Eric Moore <[email protected]>Reviewed-by Sathya Prakash <[email protected]>---
diff -aurp
mpt2sas-phase8.0/mpt2sas_base.cmpt2sas-phase8.0_wd/mpt2sas_base.c
---mpt2sas-phase8.0/mpt2sas_base.c2011-01-18 11:33:41.384202609+0530
Quoted 106 lines
+++
mpt2sas-phase8.0_wd/mpt2sas_base.c2011-01-27 20:48:35.080000040
+0530mpt2sas_base.c +32
-10@@ -522,7 +522,8 @@ _base_display_event_data(struct MPT2SAS_ desc ="Device Status Change" ;break ;case MPI2_EVENT_IR_OPERATION_STATUS : - desc ="IR Operation Status" ; +if (!ioc->hide_ir_msg) + desc ="IR Operation Status" ;break ;case MPI2_EVENT_SAS_DISCOVERY : {@@ -553,16 +554,20 @@ _base_display_event_data(struct MPT2SAS_ desc ="SAS Enclosure Device Status Change" ;break ;case MPI2_EVENT_IR_VOLUME : - desc ="IR Volume" ; +if (!ioc->hide_ir_msg) + desc ="IR Volume" ;break ;case MPI2_EVENT_IR_PHYSICAL_DISK : - desc ="IR Physical Disk" ; +if (!ioc->hide_ir_msg) + desc ="IR Physical Disk" ;break ;case MPI2_EVENT_IR_CONFIGURATION_CHANGE_LIST : - desc ="IR Configuration Change List" ; +if (!ioc->hide_ir_msg) + desc ="IR Configuration Change List" ;break ;case MPI2_EVENT_LOG_ENTRY_ADDED : - desc ="Log Entry Added" ; +if (!ioc->hide_ir_msg) + desc ="Log Entry Added" ;break ; }@@ -616,7 +621,10 @@ _base_sas_log_info(struct MPT2SAS_ADAPTE originator_str ="PL" ;break ;case 2 : - originator_str ="IR" ; +if (!ioc->hide_ir_msg) + originator_str ="IR" ; +else + originator_str ="WarpDrive" ;break ; }@@ -1508,6 +1516,7 @@ mpt2sas_base_free_smid(struct MPT2SAS_AD } ioc->scsi_lookup[i].cb_idx =0xFF ; ioc->scsi_lookup[i].scmd =NULL ; + ioc->scsi_lookup[i].direct_io =0 ;list_add_tail (&ioc->scsi_lookup[i].tracker_list, &ioc->free_list);spin_unlock_irqrestore (&ioc->scsi_lookup_lock, flags);@@ -1795,10 +1804,12 @@ _base_display_ioc_capabilities(struct MPprintk ("), " );printk ("Capabilities=(" ); -if (ioc->facts.IOCCapabilities & -MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID ) { -printk ("Raid" ); - i++; +if (!ioc->hide_ir_msg) { +if (ioc->facts.IOCCapabilities & +MPI2_IOCFACTS_CAPABILITY_INTEGRATED_RAID ) { +printk ("Raid" ); + i++; + } }if (ioc->facts.IOCCapabilities &MPI2_IOCFACTS_CAPABILITY_TLR ) {@@ -3631,6 +3642,7 @@ _base_make_ioc_operational(struct MPT2SAu32 reply_address;u16 smid;struct _tr_list *delayed_tr, *delayed_tr_next; +u8 hide_flag;dinitprintk (ioc,printk (MPT2SAS_INFO_FMT "%s\n" , ioc->name, __func__));@@ -3657,6 +3669,7 @@ _base_make_ioc_operational(struct MPT2SA ioc->scsi_lookup[i].cb_idx =0xFF ; ioc->scsi_lookup[i].smid = smid; ioc->scsi_lookup[i].scmd =NULL ; + ioc->scsi_lookup[i].direct_io =0 ;list_add_tail (&ioc->scsi_lookup[i].tracker_list, &ioc->free_list); }@@ -3717,6 +3730,15 @@ _base_make_ioc_operational(struct MPT2SAif (sleep_flag ==CAN_SLEEP )_base_static_config_pages (ioc); +if (ioc->wait_for_port_enable_to_complete && ioc->is_warpdrive) { +if (ioc->manu_pg10.OEMIdentifier ==0x80 ) { + hide_flag = (u8) (ioc->manu_pg10.OEMSpecificFlags0 & +MFG_PAGE10_HIDE_SSDS_MASK ); +if (hide_flag !=MFG_PAGE10_HIDE_SSDS_MASK ) + ioc->mfg_pg10_hide_flag = hide_flag; + } + } +if (ioc->wait_for_port_enable_to_complete) {if (diag_buffer_enable !=0 )mpt2sas_enable_diag_buffer (ioc, diag_buffer_enable);Quoted 3 lines
diff -aurp
mpt2sas-phase8.0/mpt2sas_base.hmpt2sas-phase8.0_wd/mpt2sas_base.h
---mpt2sas-phase8.0/mpt2sas_base.h2011-01-18 11:33:45.711139872+0530
Review line 70
Quoted 5 lines
+++
mpt2sas-phase8.0_wd/mpt2sas_base.h2011-01-27 20:57:45.016000126
+0530(quoted diff) +0
-0@@ -69,11 +69,11 @@ #define MPT2SAS_DRIVER_NAME "mpt2sas" #define MPT2SAS_AUTHOR "LSI Corporation <DL-Review line 71
Quoted 1 line
(quoted diff) +0
-0#define MPT2SAS_DESCRIPTION "LSI MPT Fusion SAS 2.0 DeviceDriver"
Quoted 52 lines
mpt2sas_base.h +15
-2-#define MPT2SAS_DRIVER_VERSION "08.100.00.00" +#define MPT2SAS_DRIVER_VERSION "08.100.00.01"#define MPT2SAS_MAJOR_VERSION 08#define MPT2SAS_MINOR_VERSION 100#define MPT2SAS_BUILD_VERSION 00 -#define MPT2SAS_RELEASE_VERSION 00 +#define MPT2SAS_RELEASE_VERSION 01/* * Set MPT2SAS_SG_DEPTH value based on user input. @@ -169,6 +169,16 @@#define MPT2SAS_INTEL_RMS2LL040_SSDID 0x350F/* +* WarpDrive Specific Log codes +*/ + +#define MPT2_WARPDRIVE_LOGENTRY (0x8002) +#define MPT2_WARPDRIVE_LC_SSDT (0x41) +#define MPT2_WARPDRIVE_LC_SSDLW (0x43) +#define MPT2_WARPDRIVE_LC_SSDLF (0x44) +#define MPT2_WARPDRIVE_LC_BRMF (0x4D) + +/* * per target private data */ #define MPT_TARGET_FLAGS_RAID_COMPONENT 0x01@@ -179,6 +189,7 @@* struct MPT2SAS_TARGET - starget private hostdata * @starget: starget object * @sas_address: target sas address +* @raid_device: raid_device pointer to access volume data * @handle: device handle * @num_luns: number luns * @flags: MPT_TARGET_FLAGS_XXX flags @@ -188,6 +199,7 @@struct MPT2SAS_TARGET {struct scsi_target *starget;u64 sas_address; +struct _raid_device *raid_device;u16 handle;int num_luns;u32 flags;@@ -195,6 +207,7 @@ struct MPT2SAS_TARGET {u8 tm_busy; }; +/* * per device private data */ mpt2sas_base.h typedef struct _MPI2_CONFIG_PAGE_MAN_10 · line 256
Quoted 2 lines
mpt2sas_base.h +0
-0@@ -242,6 +255,12 @@ typedef struct _MPI2_CONFIG_PAGE_MAN_10MPI2_POINTER PTR_MPI2_CONFIG_PAGE_MAN_10 , Mpi2ManufacturingPage10_t,MPI2_POINTER
pMpi2ManufacturingPage10_t;Quoted 19 lines
mpt2sas_base.h +7
-0+#define MFG_PAGE10_HIDE_SSDS_MASK (0x00000003) +#define MFG_PAGE10_HIDE_ALL_DISKS (0x00) +#define MFG_PAGE10_EXPOSE_ALL_DISKS (0x01) +#define MFG_PAGE10_HIDE_IF_VOL_PRESENT (0x02) + +struct MPT2SAS_DEVICE {struct MPT2SAS_TARGET *sas_target;unsigned int lun;@@ -321,6 +340,7 @@ struct _sas_device {* @sdev: scsi device struct (volumes are single lun) * @wwid: unique identifier for the volume * @handle: device handle +* @block_size: Block size of the volume * @id: target id * @channel: target channel * @volume_type: the raid level mpt2sas_base.h struct _sas_device { · line 356
Quoted 9 lines
mpt2sas_base.h +6
-0@@ -328,20 +348,33 @@ struct _sas_device {* @num_pds: number of hidden raid components * @responding: used in _scsih_raid_device_mark_responding * @percent_complete: resync percent complete +* @direct_io_enabled: Whether direct io to PDs are allowed or not +* @stripe_exponent: X where 2powX is the stripe sz in blocks +* @max_lba: Maximum number of LBA in the volume +* @stripe_sz: Stripe Size of the volume +* @device_info: Device info of the volume member disk +* @pd_handle: Array of handles of the physical drives for direct I/O
Quoted 63 lines
in le16
*/mpt2sas_base.h +16
-3+#define MPT_MAX_WARPDRIVE_PDS 8struct _raid_device {struct list_head list;struct scsi_target *starget;struct scsi_device *sdev;u64 wwid;u16 handle; +u16 block_sz;int id;int channel;u8 volume_type; -u32 device_info;u8 num_pds;u8 responding;u8 percent_complete; +u8 direct_io_enabled; +u8 stripe_exponent; +u64 max_lba; +u32 stripe_sz; +u32 device_info; +u16 pd_handle[MPT_MAX_WARPDRIVE_PDS ]; };/** @@ -450,6 +483,7 @@ struct chain_tracker {* @smid: system message id * @scmd: scsi request pointer * @cb_idx: callback index +* @direct_io: To indicate whether I/O is direct (WARPDRIVE) * @chain_list: list of chains associated to this IO * @tracker_list: list of free request (ioc->free_list) */ @@ -457,14 +491,14 @@ struct scsiio_tracker {u16 smid;struct scsi_cmnd *scmd;u8 cb_idx; +u8 direct_io;struct list_head chain_list;struct list_head tracker_list; };/** -* struct request_tracker - misc mf request tracker +* struct request_tracker - firmware request tracker * @smid: system message id -* @scmd: scsi request pointer * @cb_idx: callback index * @tracker_list: list of free request (ioc->free_list) */ @@ -812,6 +846,11 @@ struct MPT2SAS_ADAPTER {u32 diagnostic_flags[MPI2_DIAG_BUF_TYPE_COUNT ];u32 ring_buffer_offset;u32 ring_buffer_sz; +u8 is_warpdrive; +u8 hide_ir_msg; +u8 mfg_pg10_hide_flag; +u8 hide_drives; + }; typedef u8 (*MPT_CALLBACK)(struct MPT2SAS_ADAPTER *ioc, u16 smid, u8Quoted 4 lines
msix_index,
diff -aurpmpt2sas-phase8.0/mpt2sas_ctl.cmpt2sas-phase8.0_wd/mpt2sas_ctl.c
---mpt2sas-phase8.0/mpt2sas_ctl.c2011-01-18 11:30:28.453140352+0530
Quoted 14 lines
+++
mpt2sas-phase8.0_wd/mpt2sas_ctl.c2011-01-27 20:48:35.096000040
+0530mpt2sas_ctl.c +4
-1@@ -1034,7 +1034,10 @@ _ctl_getiocinfo(void __user *arg) __func__));memset (&karg,0 ,sizeof (karg)); - karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2 ; +if (ioc->is_warpdrive) + karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2_SSS6200 ; +else + karg.adapter_type =MPT2_IOCTL_INTERFACE_SAS2 ;if (ioc->pfacts) karg.port_number = ioc->pfacts[0 ].PortNumber;pci_read_config_byte (ioc->pdev,PCI_CLASS_REVISION , &revision);Quoted 3 lines
diff -aurp
mpt2sas-phase8.0/mpt2sas_ctl.hmpt2sas-phase8.0_wd/mpt2sas_ctl.h
---mpt2sas-phase8.0/mpt2sas_ctl.h2011-01-18 11:30:28.450141059+0530
Quoted 392 lines
+++
mpt2sas-phase8.0_wd/mpt2sas_ctl.h2011-01-19 12:13:47.568012329
+0530mpt2sas_ctl.h +1
-0@@ -133,6 +133,7 @@ struct mpt2_ioctl_pci_info {#define MPT2_IOCTL_INTERFACE_FC_IP (0x02)#define MPT2_IOCTL_INTERFACE_SAS (0x03)#define MPT2_IOCTL_INTERFACE_SAS2 (0x04) +#define MPT2_IOCTL_INTERFACE_SAS2_SSS6200 (0x05)#define MPT2_IOCTL_VERSION_LENGTH (32)/** diff -aurp
mpt2sas-phase8.0/mpt2sas_scsih.cmpt2sas-phase8.0_wd/mpt2sas_scsih.c
---mpt2sas-phase8.0/mpt2sas_scsih.c2011-01-18 11:33:43.225202675
+0530
+++mpt2sas-phase8.0_wd/mpt2sas_scsih.c2011-02-03 15:42:45.974149344
+0530mpt2sas_scsih.c +4
-0@@ -233,6 +233,9 @@ static struct pci_device_id scsih_pci_ta PCI_ANY_ID, PCI_ANY_ID }, { MPI2_MFGPAGE_VENDORID_LSI, MPI2_MFGPAGE_DEVID_SAS2308_3, PCI_ANY_ID, PCI_ANY_ID }, +/* SSS6200 */ + { MPI2_MFGPAGE_VENDORID_LSI, MPI2_MFGPAGE_DEVID_SSS6200, + PCI_ANY_ID, PCI_ANY_ID }, {0} /* Terminating entry */ };MODULE_DEVICE_TABLE (pci, scsih_pci_table);@@ -1256,6 +1259,7 @@ _scsih_target_alloc(struct scsi_target * sas_target_priv_data->handle = raid_device->handle; sas_target_priv_data->sas_address = raid_device- >wwid; sas_target_priv_data->flags |=MPT_TARGET_FLAGS_VOLUME ; + sas_target_priv_data->raid_device = raid_device; raid_device->starget = starget;} spin_unlock_irqrestore(&ioc->raid_device_lock, flags);mpt2sas_scsih.c +62
-1@@ -1455,7 +1459,10 @@ static int _scsih_is_raid(struct device *dev) {struct scsi_device *sdev =to_scsi_device (dev); +struct MPT2SAS_ADAPTER *ioc =shost_priv (sdev->host); +if (ioc->is_warpdrive) +return 0 ;return (sdev->channel ==RAID_CHANNEL ) ?1 :0 ; }@@ -1480,7 +1487,7 @@ _scsih_get_resync(struct device *dev) sdev->channel);spin_unlock_irqrestore (&ioc->raid_device_lock, flags); -if (!raid_device) +if (!raid_device || ioc->is_warpdrive) goto out; if (mpt2sas_config_get_raid_volume_pg0(ioc, &mpi_reply, &vol_pg0,@@ -1640,6 +1647,212 @@ _scsih_get_volume_capabilities(struct MPkfree (vol_pg0); } +/** +* _scsih_disable_ddio - Disable direct I/O for all the volumes +* @ioc: per adapter object +*/ +static void +_scsih_disable_ddio (struct MPT2SAS_ADAPTER *ioc) +{ +Mpi2RaidVolPage1_t vol_pg1; +Mpi2ConfigReply_t mpi_reply; +struct _raid_device *raid_device; +u16 handle; +u16 ioc_status; + + handle =0xFFFF ; +while (!(mpt2sas_config_get_raid_volume_pg1 (ioc, &mpi_reply, + &vol_pg1,MPI2_RAID_VOLUME_PGAD_FORM_GET_NEXT_HANDLE , handle))) { + ioc_status =le16_to_cpu (mpi_reply.IOCStatus) & +MPI2_IOCSTATUS_MASK ; +if (ioc_status ==MPI2_IOCSTATUS_CONFIG_INVALID_PAGE ) +break ; + handle =le16_to_cpu (vol_pg1.DevHandle); + raid_device =_scsih_raid_device_find_by_handle (ioc, handle); +if (raid_device) + raid_device->direct_io_enabled =0 ; + } +return ; +} + + +/** +* _scsih_get_num_volumes - Get number of volumes in the ioc +* @ioc: per adapter object +*/ +static u8 +_scsih_get_num_volumes (struct MPT2SAS_ADAPTER *ioc) +{ +Mpi2RaidVolPage1_t vol_pg1; +Mpi2ConfigReply_t mpi_reply; +u16 handle; +u8 vol_cnt =0 ; +u16 ioc_status; + + handle =0xFFFF ; +while (!(mpt2sas_config_get_raid_volume_pg1 (ioc, &mpi_reply, + &vol_pg1,MPI2_RAID_VOLUME_PGAD_FORM_GET_NEXT_HANDLE , handle))) { + ioc_status =le16_to_cpu (mpi_reply.IOCStatus) & +MPI2_IOCSTATUS_MASK ; +if (ioc_status ==MPI2_IOCSTATUS_CONFIG_INVALID_PAGE ) +break ; + vol_cnt++; + handle =le16_to_cpu (vol_pg1.DevHandle); + } +return vol_cnt; +} + + +/** +* _scsih_init_warpdrive_properties - Set properties for warpdrive direct I/O.
+ * @ioc: per adapter object
+ * @raid_device: theraid_deviceobject
+ */mpt2sas_scsih.c +20
-0+static void +_scsih_init_warpdrive_properties(struct MPT2SAS_ADAPTER *ioc, + struct _raid_device *raid_device) +{ + Mpi2RaidVolPage0_t *vol_pg0; + Mpi2RaidPhysDiskPage0_t pd_pg0; + Mpi2ConfigReply_t mpi_reply; + u16 sz; + u8 num_pds, count; + u64 mb = 1024 * 1024; + u64 tb_2 = 2 * mb * mb; + u64 capacity; + u32 stripe_sz; + u8 i, stripe_exp; + + if (!ioc->is_warpdrive) + return; + + if (ioc->mfg_pg10_hide_flag == MFG_PAGE10_EXPOSE_ALL_DISKS) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +6
-0+ "globally as drives are exposed\n", ioc->name); +return ; + } + if (_scsih_get_num_volumes(ioc) > 1) { + _scsih_disable_ddio(ioc); + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +6
-0+ "globally as number of drives > 1\n", ioc->name); +return ; + } + if ((mpt2sas_config_get_number_pds(ioc, raid_device->handle, + &num_pds)) || !num_pds) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +9
-0+ "Failure in computing number of drives\n", ioc->name); +return ; + } + + sz = offsetof(Mpi2RaidVolPage0_t , PhysDisk) + (num_pds * +sizeof (Mpi2RaidVol0PhysDisk_t)); + vol_pg0 =kzalloc (sz,GFP_KERNEL ); + if (!vol_pg0) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +6
-0+ "Memory allocation failure for RVPG0\n", ioc->name); +return ; + } + + if ((mpt2sas_config_get_raid_volume_pg0(ioc, &mpi_reply, vol_pg0, + MPI2_RAID_VOLUME_PGAD_FORM_HANDLE, raid_device->handle,sz))) {
+ printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled
"mpt2sas_scsih.c +7
-0+ "Failure in retrieving RVPG0\n", ioc->name); +kfree (vol_pg0); +return ; + } + +/* +* WARPDRIVE:If number of physical disks in a volume exceeds the max pds
mpt2sas_scsih.c +4
-0+* assumed for WARPDRIVE, disable direct I/O +*/ + if (num_pds > MPT_MAX_WARPDRIVE_PDS) { + printk(MPT2SAS_WARN_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +13
-0+"for the drive with handle(0x%04x): num_mem=%d, " +"max_mem_allowed=%d\n" , ioc->name, raid_device->handle, + num_pds, MPT_MAX_WARPDRIVE_PDS); +kfree (vol_pg0); +return ; + } + for (count = 0; count < num_pds; count++) { + if (mpt2sas_config_get_phys_disk_pg0(ioc, &mpi_reply, + &pd_pg0, MPI2_PHYSDISK_PGAD_FORM_PHYSDISKNUM, + vol_pg0->PhysDisk[count].PhysDiskNum) || + pd_pg0.DevHandle == MPT2SAS_INVALID_DEVICE_HANDLE) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is " + "disabled for the drive with handle(0x%04x)member"
mpt2sas_scsih.c +6
-0+"handle retrieval failed for member number=%d\n" , + ioc->name, raid_device->handle, + vol_pg0->PhysDisk[count].PhysDiskNum); + goto out_error; + } + raid_device->pd_handle[count] =
le16_to_cpu(pd_pg0.DevHandle);mpt2sas_scsih.c +4
-0+ } + +/* +* Assumption for WD: Direct I/O is not supported if the volume is
+ * not RAID0, if the stripe size is not 64KB, if the block size
ismpt2sas_scsih.c +5
-0+* not 512 and if the volume size is >2TB +*/ + if (raid_device->volume_type != MPI2_RAID_VOL_TYPE_RAID0 || + le16_to_cpu(vol_pg0->BlockSize) != 512) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +13
-0+"for the drive with handle(0x%04x): type=%d, " +"s_sz=%uK, blk_size=%u\n" , ioc->name, + raid_device->handle, raid_device->volume_type, +le32_to_cpu (vol_pg0->StripeSize)/2 , + le16_to_cpu(vol_pg0->BlockSize)); + goto out_error; + } + + capacity = (u64 )le16_to_cpu (vol_pg0->BlockSize) * + (le64_to_cpu (vol_pg0->MaxLBA) +1 ); + + if (capacity > tb_2) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
mpt2sas_scsih.c +15
-0+"for the drive with handle(0x%04x) since drive sz > 2TB\n" , + ioc->name, raid_device->handle); + goto out_error; + } + + stripe_sz =le32_to_cpu (vol_pg0->StripeSize); + stripe_exp =0 ; +for (i =0 ; i <32 ; i++) { +if (stripe_sz &1 ) +break ; + stripe_exp++; + stripe_sz >>=1 ; + } + if (i == 32) { + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is disabled"
+ "for the drive with handle(0x%04x) invalid stripe sz
%uK\n",mpt2sas_scsih.c +8
-0+ ioc->name, raid_device->handle, + le32_to_cpu(vol_pg0->StripeSize)/2); + goto out_error; + } + raid_device->stripe_exponent = stripe_exp; + raid_device->direct_io_enabled =1 ; + + printk(MPT2SAS_INFO_FMT "WarpDrive : Direct IO is Enabled for thedrive"
mpt2sas_scsih.c +3
-0+ " with handle(0x%04x)\n", ioc->name, raid_device->handle); +/* +* WARPDRIVE: Though the following fields are not used for direct IO,
mpt2sas_scsih.c +30
-6+* stored for future purpose: +*/ + raid_device->max_lba =le64_to_cpu (vol_pg0->MaxLBA); + raid_device->stripe_sz =le32_to_cpu (vol_pg0->StripeSize); + raid_device->block_sz =le16_to_cpu (vol_pg0->BlockSize); + + +kfree (vol_pg0); +return ; + +out_error: + raid_device->direct_io_enabled =0 ; +for (count =0 ; count < num_pds; count++) + raid_device->pd_handle[count] =0 ; +kfree (vol_pg0); +return ; +}/** * _scsih_enable_tlr - setting TLR flags @@ -1710,6 +1923,11 @@ _scsih_slave_configure(struct scsi_devic_scsih_get_volume_capabilities (ioc, raid_device); +/* +* WARPDRIVE: Initialize the required data for Direct IO +*/ +_scsih_init_warpdrive_properties (ioc, raid_device); +/* RAID Queue Depth Support * IS volume = underlying qdepth of drive type, either * MPT2SAS_SAS_QUEUE_DEPTH or MPT2SAS_SATA_QUEUE_DEPTH @@ -1757,14 +1975,16 @@ _scsih_slave_configure(struct scsi_devicbreak ; } -sdev_printk (KERN_INFO , sdev,"%s: " - "handle(0x%04x), wwid(0x%016llx), pd_count(%d), type(%s)\n", - r_level, raid_device->handle, - (unsigned long long )raid_device->wwid, - raid_device->num_pds, ds); + if (!ioc->hide_ir_msg) + sdev_printk(KERN_INFO, sdev, "%s: handle(0x%04x), " +"wwid(0x%016llx), pd_count(%d), type(%s)\n" , + r_level, raid_device->handle, + (unsigned long long )raid_device->wwid, + raid_device->num_pds, ds);_scsih_change_queue_depth (sdev, qdepth,SCSI_QDEPTH_DEFAULT );/* raid transport support */ -_scsih_set_level (sdev, raid_device); +if (!ioc->is_warpdrive) +_scsih_set_level (sdev, raid_device);return 0 ;}mpt2sas_scsih.c +5
-1@@ -2182,16 +2402,20 @@ _scsih_tm_display_info(struct MPT2SAS_ADstruct MPT2SAS_TARGET *priv_target = starget->hostdata;struct _sas_device *sas_device =NULL ;unsigned long flags; +char *device_str =NULL ;if (!priv_target)return ; +if (ioc->hide_ir_msg) + device_str ="WarpDrive" ; +else + device_str ="volume" ;scsi_print_command (scmd);if (priv_target->flags &MPT_TARGET_FLAGS_VOLUME ) { - starget_printk(KERN_INFO, starget, "volume handle(0x%04x),"
mpt2sas_scsih.c +2
-3-"volume wwid(0x%016llx)\n" , - priv_target->handle, - (unsigned long long)priv_target->sas_address); + starget_printk(KERN_INFO, starget, "%s handle(0x%04x), " + "%s wwid(0x%016llx)\n", device_str, priv_target-Quoted 1 line
handle,
+
device_str, (unsigned long long)priv_target-Quoted 1 line
sas_address);} else { spin_lock_irqsave(&ioc->sas_device_lock, flags); sas_device =mpt2sas_scsih_sas_device_find_by_sas_address(ioc,
mpt2sas_scsih.c +3
-0@@ -3130,6 +3354,9 @@ _scsih_check_ir_config_unhide_events(str a =0 ; b =0 ; +if (ioc->is_warpdrive) +return ; +/* Volume Resets for Deleted or Removed */ element = (Mpi2EventIrConfigElement_t *)&event_data- >ConfigElement[0];for (i = 0; i < event_data->NumElements; i++, element++) {mpt2sas_scsih.c +20
-0@@ -3347,6 +3574,105 @@ _scsih_eedp_error_handling(struct scsi_c }/** +* _scsih_scsi_direct_io_get - returns direct io flag +* @ioc: per adapter object +* @smid: system request message index +* +* Returns the smid stored scmd pointer. +*/ +static inline u8 +_scsih_scsi_direct_io_get (struct MPT2SAS_ADAPTER *ioc,u16 smid) +{ +return ioc->scsi_lookup[smid -1 ].direct_io; +} + +/** +* _scsih_scsi_direct_io_set - sets direct io flag +* @ioc: per adapter object +* @smid: system request message index +* @direct_io: Zero or non-zero value to set in the direct_io flag +* +* Returns Nothing. +*/ mpt2sas_scsih.c _scsih_eedp_error_handling(struct scsi_c · line 3606
Quoted 10 lines
mpt2sas_scsih.c +9
-0+static inline void +_scsih_scsi_direct_io_set (struct MPT2SAS_ADAPTER *ioc,u16 smid,u8 direct_io) +{ + ioc->scsi_lookup[smid -1 ].direct_io = direct_io; +} + + +/** +* _scsih_setup_direct_io - setup MPI request for WARPDRIVE Direct I/O
Quoted 591 lines
mpt2sas_scsih.c +26
-0+* @ioc: per adapter object +* @scmd: pointer to scsi command object +* @raid_device: pointer to raid device data structure +* @mpi_request: pointer to the SCSI_IO reqest message frame +* @smid: system request message index +* +* Returns nothing +*/ +static void +_scsih_setup_direct_io (struct MPT2SAS_ADAPTER *ioc,struct scsi_cmnd *scmd, +struct _raid_device *raid_device,Mpi2SCSIIORequest_t *mpi_request, +u16 smid) +{ +u32 v_lba, p_lba, stripe_off, stripe_unit, column, io_size; +u32 stripe_sz, stripe_exp; +u8 num_pds, *cdb_ptr, *tmp_ptr, *lba_ptr1, *lba_ptr2; +u8 cdb0 = scmd->cmnd[0 ]; + +/* +* Try Direct I/O to RAID memeber disks +*/ +if (cdb0 ==READ_16 || cdb0 ==READ_10 || + cdb0 ==WRITE_16 || cdb0 ==WRITE_10 ) { + cdb_ptr = mpi_request->CDB.CDB32; + + if ((cdb0 < READ_16) || !(cdb_ptr[2] | cdb_ptr[3] |cdb_ptr[4]
mpt2sas_scsih.c +4
-0+ | cdb_ptr[5])) { + io_size =scsi_bufflen (scmd) >>9 ; +/* get virtual lba */ + lba_ptr1 = lba_ptr2 = (cdb0 < READ_16) ? &cdb_ptr[2]:
mpt2sas_scsih.c +43
-2+ &cdb_ptr[6 ]; + tmp_ptr = (u8 *)&v_lba +3 ; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr-- = *lba_ptr1++; + *tmp_ptr = *lba_ptr1; + +if (((u64 )v_lba + (u64 )io_size -1 ) <= + (u32 )raid_device->max_lba) { + stripe_sz = raid_device->stripe_sz; + stripe_exp = raid_device->stripe_exponent; + stripe_off = v_lba & (stripe_sz -1 ); + +/* Check whether IO falls within a stripe */ +if ((stripe_off + io_size) <= stripe_sz) { + num_pds = raid_device->num_pds; + p_lba = v_lba >> stripe_exp; + stripe_unit = p_lba / num_pds; + column = p_lba % num_pds; + p_lba = (stripe_unit << stripe_exp) + + stripe_off; + mpi_request->DevHandle = +cpu_to_le16 (raid_device-> + pd_handle[column]); + tmp_ptr = (u8 *)&p_lba +3 ; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2++ = *tmp_ptr--; + *lba_ptr2 = *tmp_ptr; +/* +* WD: To indicate this I/O is directI/O +*/ +_scsih_scsi_direct_io_set (ioc, smid,1 ); + } + } + } + } +} + +/** * _scsih_qcmd - main scsi request entry point * @scmd: pointer to scsi command object * @done: function pointer to be invoked on completion @@ -3363,6 +3689,7 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd,struct MPT2SAS_ADAPTER *ioc =shost_priv (scmd->device->host);struct MPT2SAS_DEVICE *sas_device_priv_data;struct MPT2SAS_TARGET *sas_target_priv_data; +struct _raid_device *raid_device;Mpi2SCSIIORequest_t *mpi_request;u32 mpi_control;u16 smid;@@ -3424,8 +3751,10 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd, }else mpi_control |=MPI2_SCSIIO_CONTROL_SIMPLEQ ; -/* Make sure Device is not raid volume */ - if (!_scsih_is_raid(&scmd->device->sdev_gendev) && +/* Make sure Device is not raid volume. +* We do not expose raid functionality to upper layer for warpdrive.
(quoted diff) +2
-0+ */ + if (!ioc->is_warpdrive && _scsih_is_raid(&scmd->device-Quoted 1 line
sdev_gendev) &&sas_is_tlr_enabled(scmd->device) && scmd->cmd_len != 32) mpi_control |= MPI2_SCSIIO_CONTROL_TLR_ON;mpt2sas_scsih.c +6
-1@@ -3473,9 +3802,14 @@ _scsih_qcmd_lck(struct scsi_cmnd *scmd, } } + raid_device = sas_target_priv_data->raid_device; +if (raid_device && raid_device->direct_io_enabled) +_scsih_setup_direct_io (ioc, scmd, raid_device, mpi_request, + smid); +if (likely (mpi_request->Function ==MPI2_FUNCTION_SCSI_IO_REQUEST ))mpt2sas_base_put_smid_scsi_io (ioc, smid, - sas_device_priv_data->sas_target->handle); +le16_to_cpu (mpi_request->DevHandle));else mpt2sas_base_put_smid_default (ioc, smid);return 0;mpt2sas_scsih.c +8
-2@@ -3540,10 +3874,16 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAPunsigned long flags;struct scsi_target *starget = scmd->device->sdev_target;struct MPT2SAS_TARGET *priv_target = starget->hostdata; +char *device_str =NULL ;if (!priv_target)return ; +if (ioc->hide_ir_msg) + device_str ="WarpDrive" ; +else + device_str ="volume" ; +if (log_info ==0x31170000 )return ;@@ -3660,8 +4000,8 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAPscsi_print_command (scmd);if (priv_target->flags &MPT_TARGET_FLAGS_VOLUME ) { -printk (MPT2SAS_WARN_FMT "\tvolume wwid(0x%016llx)\n" , ioc- >name, - (unsigned long long )priv_target->sas_address); +printk (MPT2SAS_WARN_FMT "\t%s wwid(0x%016llx)\n" , ioc- >name, + device_str, (unsigned long long )priv_target- >sas_address);} else { spin_lock_irqsave(&ioc->sas_device_lock, flags); sas_device =mpt2sas_scsih_sas_device_find_by_sas_address(ioc,
mpt2sas_scsih.c +16
-1@@ -3840,6 +4180,20 @@ _scsih_io_done(struct MPT2SAS_ADAPTER *i scmd->result =DID_NO_CONNECT <<16 ; goto out; } +/* +* WARPDRIVE: If direct_io is set then it is directIO, +* the failed direct I/O should be redirected to volume +*/ +if (_scsih_scsi_direct_io_get (ioc, smid)) { +_scsih_scsi_direct_io_set (ioc, smid,0 ); +memcpy (mpi_request->CDB.CDB32, scmd->cmnd, scmd->cmd_len); + mpi_request->DevHandle = +cpu_to_le16 (sas_device_priv_data->sas_target->handle); +mpt2sas_base_put_smid_scsi_io (ioc, smid, + sas_device_priv_data->sas_target->handle); +return 0 ; + } +/* turning off TLR */ scsi_state = mpi_reply->SCSIState;@@ -3848,7 +4202,10 @@ _scsih_io_done(struct MPT2SAS_ADAPTER *ile32_to_cpu (mpi_reply->ResponseInfo) &0xFF ;if (!sas_device_priv_data->tlr_snoop_check) { sas_device_priv_data->tlr_snoop_check++; - if (!_scsih_is_raid(&scmd->device->sdev_gendev) && +/* Make sure Device is not raid volume. +* We do not expose raid functionality to upper layer for warpdrive.
(quoted diff) +2
-0+ */ + if (!ioc->is_warpdrive && !_scsih_is_raid(&scmd->device-Quoted 1 line
sdev_gendev) &&sas_is_tlr_enabled(scmd->device) && response_code == MPI2_SCSITASKMGMT_RSP_INVALID_FRAME) { sas_disable_tlr(scmd->device);mpt2sas_scsih.c +7
-3@@ -4681,8 +5038,10 @@ _scsih_remove_device(struct MPT2SAS_ADAP_scsih_ublock_io_device (ioc, sas_device_backup.handle); -mpt2sas_transport_port_remove (ioc, sas_device_backup.sas_address, - sas_device_backup.sas_address_parent); +if (!ioc->hide_drives) +mpt2sas_transport_port_remove (ioc, + sas_device_backup.sas_address, + sas_device_backup.sas_address_parent); printk(MPT2SAS_INFO_FMT "removing handle(0x%04x), sas_addr" "(0x%016llx)\n", ioc->name, sas_device_backup.handle,@@ -5413,6 +5772,7 @@ _scsih_sas_pd_hide(struct MPT2SAS_ADAPTE &sas_device->volume_wwid);set_bit (handle, ioc->pd_handles);_scsih_reprobe_target (sas_device->starget,1 ); + }/** @@ -5591,7 +5951,8 @@ _scsih_sas_ir_config_change_event(structMpi2EventDataIrConfigChangeList_t *event_data = fw_event- >event_data;#ifdef CONFIG_SCSI_MPT2SAS_LOGGING -if (ioc->logging_level &MPT_DEBUG_EVENT_WORK_TASK ) +if ((ioc->logging_level &MPT_DEBUG_EVENT_WORK_TASK ) + && !ioc->hide_ir_msg)_scsih_sas_ir_config_change_event_debug (ioc, event_data);#endif
mpt2sas_scsih.c +10
-7@@ -5614,16 +5975,20 @@ _scsih_sas_ir_config_change_event(struct le16_to_cpu(element->VolDevHandle));break ;case MPI2_EVENT_IR_CHANGE_RC_PD_CREATED : -_scsih_sas_pd_hide (ioc, element); +if (!ioc->is_warpdrive) +_scsih_sas_pd_hide (ioc, element);break ;case MPI2_EVENT_IR_CHANGE_RC_PD_DELETED : -_scsih_sas_pd_expose (ioc, element); +if (!ioc->is_warpdrive) +_scsih_sas_pd_expose (ioc, element);break ;case MPI2_EVENT_IR_CHANGE_RC_HIDE : -_scsih_sas_pd_add (ioc, element); +if (!ioc->is_warpdrive) +_scsih_sas_pd_add (ioc, element);break ;case MPI2_EVENT_IR_CHANGE_RC_UNHIDE : -_scsih_sas_pd_delete (ioc, element); +if (!ioc->is_warpdrive) +_scsih_sas_pd_delete (ioc, element);break ; } }@@ -5654,9 +6019,10 @@ _scsih_sas_ir_volume_event(struct MPT2SA handle =le16_to_cpu (event_data->VolDevHandle); state =le32_to_cpu (event_data->NewValue); -dewtprintk (ioc,printk (MPT2SAS_INFO_FMT "%s: handle(0x%04x), " -"old(0x%08x), new(0x%08x)\n" , ioc->name, __func__, handle, -le32_to_cpu (event_data->PreviousValue), state)); + if (!ioc->hide_ir_msg) + dewtprintk(ioc, printk(MPT2SAS_INFO_FMT "%s:handle(0x%04x), "
+ "old(0x%08x), new(0x%08x)\n",ioc->name,__func__,
handle,mpt2sas_scsih.c +3
-3+ le32_to_cpu(event_data->PreviousValue), state));switch (state) {case MPI2_RAID_VOL_STATE_MISSING :@@ -5736,9 +6102,10 @@ _scsih_sas_ir_physical_disk_event(struct handle =le16_to_cpu (event_data->PhysDiskDevHandle); state =le32_to_cpu (event_data->NewValue); -dewtprintk (ioc,printk (MPT2SAS_INFO_FMT "%s: handle(0x%04x), " -"old(0x%08x), new(0x%08x)\n" , ioc->name, __func__, handle, -le32_to_cpu (event_data->PreviousValue), state)); + if (!ioc->hide_ir_msg) + dewtprintk(ioc, printk(MPT2SAS_INFO_FMT "%s:handle(0x%04x), "
+ "old(0x%08x), new(0x%08x)\n",ioc->name,__func__,
handle,mpt2sas_scsih.c +6
-3+ le32_to_cpu(event_data->PreviousValue), state));switch (state) {case MPI2_RAID_PD_STATE_ONLINE :@@ -5747,7 +6114,8 @@ _scsih_sas_ir_physical_disk_event(structcase MPI2_RAID_PD_STATE_OPTIMAL :case MPI2_RAID_PD_STATE_HOT_SPARE : -set_bit (handle, ioc->pd_handles); +if (!ioc->is_warpdrive) +set_bit (handle, ioc->pd_handles);spin_lock_irqsave (&ioc->sas_device_lock, flags); sas_device =_scsih_sas_device_find_by_handle (ioc, handle);@@ -5851,7 +6219,8 @@ _scsih_sas_ir_operation_status_event(stru16 handle;#ifdef CONFIG_SCSI_MPT2SAS_LOGGING -if (ioc->logging_level &MPT_DEBUG_EVENT_WORK_TASK ) +if ((ioc->logging_level &MPT_DEBUG_EVENT_WORK_TASK ) + && !ioc->hide_ir_msg)_scsih_sas_ir_operation_status_event_debug (ioc, event_data);#endif @@ -5910,7 +6279,7 @@ static void _scsih_mark_responding_sas_device(struct MPT2SAS_ADAPTER *ioc, u64 sas_address, u16 slot, u16 handle) { - struct MPT2SAS_TARGET *sas_target_priv_data; + struct MPT2SAS_TARGET *sas_target_priv_data = NULL;struct scsi_target *starget;struct _sas_device *sas_device;unsigned long flags;mpt2sas_scsih.c +10
-8@@ -5918,7 +6287,7 @@ _scsih_mark_responding_sas_device(structspin_lock_irqsave (&ioc->sas_device_lock, flags);list_for_each_entry (sas_device, &ioc->sas_device_list, list) {if (sas_device->sas_address == sas_address && - sas_device->slot == slot && sas_device->starget) { + sas_device->slot == slot) { sas_device->responding =1 ; starget = sas_device->starget;if (starget && starget->hostdata) {@@ -5927,13 +6296,15 @@ _scsih_mark_responding_sas_device(struct sas_target_priv_data->deleted =0 ; }else sas_target_priv_data =NULL ; -starget_printk (KERN_INFO , sas_device->starget, -"handle(0x%04x), sas_addr(0x%016llx), enclosure " -"logical id(0x%016llx), slot(%d)\n" , handle, - (unsigned long long )sas_device->sas_address, - (unsigned long long ) - sas_device->enclosure_logical_id, - sas_device->slot); +if (starget) +starget_printk (KERN_INFO , starget, +"handle(0x%04x), sas_addr(0x%016llx), " +"enclosure logical id(0x%016llx), " +"slot(%d)\n" , handle, + (unsigned long long )sas_device- >sas_address, + (unsigned long long ) + sas_device->enclosure_logical_id, + sas_device->slot);if (sas_device->handle == handle) goto out;printk(KERN_INFO "\thandle changed
from(0x%04x)!!!\n",mpt2sas_scsih.c +2
-0@@ -6025,6 +6396,12 @@ _scsih_mark_responding_raid_device(strucstarget_printk (KERN_INFO , raid_device->starget,"handle(0x%04x), wwid(0x%016llx)\n" , handle, (unsigned long long )raid_device->wwid); +/* +* WARPDRIVE: The handles of the PDs might have changed
mpt2sas_scsih.c +4
-0+* across the host reset so re-initialize the +* required data for Direct IO +*/ +_scsih_init_warpdrive_properties (ioc, raid_device);if (raid_device->handle == handle) goto out; printk(KERN_INFO "\thandle changedfrom(0x%04x)!!!\n",
mpt2sas_scsih.c +58
-12@@ -6086,18 +6463,20 @@ _scsih_search_responding_raid_devices(st }/* refresh the pd_handles */ - phys_disk_num =0xFF ; -memset (ioc->pd_handles,0 , ioc->pd_handles_sz); -while (!(mpt2sas_config_get_phys_disk_pg0 (ioc, &mpi_reply, - &pd_pg0,MPI2_PHYSDISK_PGAD_FORM_GET_NEXT_PHYSDISKNUM , - phys_disk_num))) { - ioc_status =le16_to_cpu (mpi_reply.IOCStatus) & -MPI2_IOCSTATUS_MASK ; -if (ioc_status ==MPI2_IOCSTATUS_CONFIG_INVALID_PAGE ) -break ; - phys_disk_num = pd_pg0.PhysDiskNum; - handle =le16_to_cpu (pd_pg0.DevHandle); -set_bit (handle, ioc->pd_handles); +if (!ioc->is_warpdrive) { + phys_disk_num =0xFF ; +memset (ioc->pd_handles,0 , ioc->pd_handles_sz); +while (!(mpt2sas_config_get_phys_disk_pg0 (ioc, &mpi_reply, + &pd_pg0,MPI2_PHYSDISK_PGAD_FORM_GET_NEXT_PHYSDISKNUM , + phys_disk_num))) { + ioc_status =le16_to_cpu (mpi_reply.IOCStatus) & +MPI2_IOCSTATUS_MASK ; +if (ioc_status ==MPI2_IOCSTATUS_CONFIG_INVALID_PAGE ) +break ; + phys_disk_num = pd_pg0.PhysDiskNum; + handle =le16_to_cpu (pd_pg0.DevHandle); +set_bit (handle, ioc->pd_handles); + } } }@@ -6243,6 +6622,50 @@ _scsih_remove_unresponding_sas_devices(s }/** +* _scsih_hide_unhide_sas_devices - add/remove device to/from OS +* @ioc: per adapter object +* +* Return nothing. +*/ +static void +_scsih_hide_unhide_sas_devices (struct MPT2SAS_ADAPTER *ioc) +{ +struct _sas_device *sas_device, *sas_device_next; + +if (!ioc->is_warpdrive || ioc->mfg_pg10_hide_flag != +MFG_PAGE10_HIDE_IF_VOL_PRESENT ) +return ; + +if (ioc->hide_drives) { +if (_scsih_get_num_volumes (ioc)) +return ; + ioc->hide_drives =0 ; +list_for_each_entry_safe (sas_device, sas_device_next, + &ioc->sas_device_list, list) { +if (!mpt2sas_transport_port_add (ioc, sas_device- >handle, + sas_device->sas_address_parent)) { +_scsih_sas_device_remove (ioc, sas_device); + }else if (!sas_device->starget) { +mpt2sas_transport_port_remove (ioc, + sas_device->sas_address, + sas_device->sas_address_parent); +_scsih_sas_device_remove (ioc, sas_device); + } + } + }else { +if (!_scsih_get_num_volumes (ioc)) +return ; + ioc->hide_drives =1 ; +list_for_each_entry_safe (sas_device, sas_device_next, + &ioc->sas_device_list, list) { +mpt2sas_transport_port_remove (ioc, + sas_device->sas_address, + sas_device->sas_address_parent); + } + } +} + +/** * mpt2sas_scsih_reset_handler - reset callback handler (for scsih) * @ioc: per adapter object * @reset_phase: phase
mpt2sas_scsih.c +27
-0@@ -6326,6 +6749,7 @@ _firmware_event_work(struct work_structspin_unlock_irqrestore (&ioc- >ioc_reset_in_progress_lock, flags);_scsih_remove_unresponding_sas_devices (ioc); +_scsih_hide_unhide_sas_devices (ioc);return ; }@@ -6425,6 +6849,53 @@ mpt2sas_scsih_event_callback(struct MPT2 (Mpi2EventDataIrVolume_t *) mpi_reply->EventData);break ; +case MPI2_EVENT_LOG_ENTRY_ADDED : + { + Mpi2EventDataLogEntryAdded_t *log_entry; + u32 *log_code; + + if (!ioc->is_warpdrive) + break; + + log_entry = (Mpi2EventDataLogEntryAdded_t *) + mpi_reply->EventData; + log_code = (u32 *)log_entry->LogData; + + if (le16_to_cpu(log_entry->LogEntryQualifier) + != MPT2_WARPDRIVE_LOGENTRY) + break; + + switch (le32_to_cpu(*log_code)) { + case MPT2_WARPDRIVE_LC_SSDT: + printk(MPT2SAS_WARN_FMT "WarpDrive Warning: " + "IO Throttling has occurred in the WarpDrive " + "subsystem. Check WarpDrive documentation for " + "additional details.\n", ioc->name); + break; + case MPT2_WARPDRIVE_LC_SSDLW: + printk(MPT2SAS_WARN_FMT "WarpDrive Warning: " + "Program/Erase Cycles for the WarpDrive subsystem"
+ "in degraded range. Check WarpDrive documentation
"mpt2sas_scsih.c +6
-0+ "for additional details.\n", ioc->name); +break ; +case MPT2_WARPDRIVE_LC_SSDLF : +printk (MPT2SAS_ERR_FMT "WarpDrive Fatal Error: " +"There are no Program/Erase Cycles for the " + "WarpDrive subsystem. The storage device will be"
+ "in read-only mode. Check WarpDrive documentation
"mpt2sas_scsih.c +15
-1+ "for additional details.\n", ioc->name); +break ; +case MPT2_WARPDRIVE_LC_BRMF : +printk (MPT2SAS_ERR_FMT "WarpDrive Fatal Error: " +"The Backup Rail Monitor has failed on the " +"WarpDrive subsystem. Check WarpDrive " +"documentation for additional details.\n" , + ioc->name); +break ; + } + +break ; + }case MPI2_EVENT_SAS_DEVICE_STATUS_CHANGE :case MPI2_EVENT_IR_OPERATION_STATUS :case MPI2_EVENT_SAS_DISCOVERY :@@ -6583,7 +7054,8 @@ _scsih_ir_shutdown(struct MPT2SAS_ADAPTE mpi_request->Function =MPI2_FUNCTION_RAID_ACTION ; mpi_request->Action =MPI2_RAID_ACTION_SYSTEM_SHUTDOWN_INITIATED ; -printk (MPT2SAS_INFO_FMT "IR shutdown (sending)\n" , ioc->name); +if (!ioc->hide_ir_msg) +printk (MPT2SAS_INFO_FMT "IR shutdown (sending)\n" , ioc- >name);init_completion (&ioc->scsih_cmds.done);mpt2sas_base_put_smid_default (ioc, smid);wait_for_completion_timeout(&ioc->scsih_cmds.done, 10*HZ);mpt2sas_scsih.c +30
-4@@ -6597,10 +7069,11 @@ _scsih_ir_shutdown(struct MPT2SAS_ADAPTEif (ioc->scsih_cmds.status &MPT2_CMD_REPLY_VALID ) { mpi_reply = ioc->scsih_cmds.reply; -printk (MPT2SAS_INFO_FMT "IR shutdown (complete): " -"ioc_status(0x%04x), loginfo(0x%08x)\n" , - ioc->name,le16_to_cpu (mpi_reply->IOCStatus), -le32_to_cpu (mpi_reply->IOCLogInfo)); +if (!ioc->hide_ir_msg) +printk (MPT2SAS_INFO_FMT "IR shutdown (complete): " +"ioc_status(0x%04x), loginfo(0x%08x)\n" , + ioc->name,le16_to_cpu (mpi_reply->IOCStatus), +le32_to_cpu (mpi_reply->IOCLogInfo)); } out:@@ -6759,6 +7232,9 @@ _scsih_probe_boot_devices(struct MPT2SASspin_lock_irqsave (&ioc->sas_device_lock, flags);list_move_tail (&sas_device->list, &ioc->sas_device_list);spin_unlock_irqrestore (&ioc->sas_device_lock, flags); + +if (ioc->hide_drives) +return ;if (!mpt2sas_transport_port_add (ioc, sas_device->handle, sas_device->sas_address_parent)) {_scsih_sas_device_remove (ioc, sas_device);@@ -6812,6 +7288,9 @@ _scsih_probe_sas(struct MPT2SAS_ADAPTERlist_move_tail (&sas_device->list, &ioc->sas_device_list);spin_unlock_irqrestore (&ioc->sas_device_lock, flags); +if (ioc->hide_drives) +continue ; +if (!mpt2sas_transport_port_add (ioc, sas_device->handle, sas_device->sas_address_parent)) {_scsih_sas_device_remove (ioc, sas_device);@@ -6882,6 +7361,11 @@ _scsih_probe(struct pci_dev *pdev, const ioc->id = mpt_ids++;sprintf (ioc->name,"%s%d" ,MPT2SAS_DRIVER_NAME , ioc->id); ioc->pdev = pdev; +if (id->device ==MPI2_MFGPAGE_DEVID_SSS6200 ) { + ioc->is_warpdrive =1 ; + ioc->hide_ir_msg =1 ; + }else + ioc->mfg_pg10_hide_flag =MFG_PAGE10_EXPOSE_ALL_DISKS ; ioc->scsi_io_cb_idx = scsi_io_cb_idx; ioc->tm_cb_idx = tm_cb_idx; ioc->ctl_cb_idx = ctl_cb_idx;@@ -6947,6 +7431,20 @@ _scsih_probe(struct pci_dev *pdev, const } ioc->wait_for_port_enable_to_complete =0 ; +if (ioc->is_warpdrive) { +if (ioc->mfg_pg10_hide_flag ==MFG_PAGE10_EXPOSE_ALL_DISKS ) + ioc->hide_drives =0 ; +else if (ioc->mfg_pg10_hide_flag ==MFG_PAGE10_HIDE_ALL_DISKS ) + ioc->hide_drives =1 ; +else { +if (_scsih_get_num_volumes (ioc)) + ioc->hide_drives =1 ; +else + ioc->hide_drives =0 ; + } + }else + ioc->hide_drives =0 ; +_scsih_probe_devices (ioc);return 0;--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html