Add some kind of unique_id attribute to disks in scsi mid layer?
Would it be a reasonable idea to add some sort of unique_id attribute to scsi devices in the mid layer?
For example, sg_inq, from sg3_utils, will print out a serial number:
[root@localhost scameron]# sg_inq /dev/sda
standard INQUIRY:
PQual=0 Device_type=0 RMB=0 version=0x05 [SPC-3] [AERC=0] [TrmTsk=0] NormACA=0 HiSUP=0 Resp_data_format=2 SCCS=0 ACC=0 TPGS=0 3PC=0 Protect=0 BQue=0 EncServ=0 MultiP=0 [MChngr=0] [ACKREQQ=0] Addr16=0 [RelAdr=0] WBus16=0 Sync=0 Linked=0 [TranDis=0] CmdQue=1
length=56 (0x38) Peripheral device type: disk
Vendor identification: HP
Product identification: LOGICAL VOLUME
Product revision level: 3.66
Unit serial number: 50014380065020C0
And there's also some stuff in page 0x83 on some devices which might be useful as suck an identifier:
[root@localhost scameron]# sg_inq --page 0x83 /dev/sda VPD INQUIRY: Device Identification page
Designation descriptor number 1, descriptor length: 20
designator_type: NAA, code_set: Binary
associated with the addressed logical unit
NAA 6, IEEE Company_id: 0x508b
Vendor Specific Identifier: 0x1001ce88b
Vendor Specific Identifier Extension: 0x746f381eedf6577
[0x600508b1001ce88b0746f381eedf6577] Designation descriptor number 2, descriptor length: 8
designator_type: vendor specific [0x0], code_set: Binary associated with the addressed logical unit
00 00 00 00 00 ....
[root@localhost scameron]#
The hpsa driver, for example, currently exports a "unique_id" attribute itself for disks, which is the same data reported by inquire page 0x83.
[root@localhost 0:0:0:1]# pwd
/sys/bus/scsi/devices/0:0:0:1
[root@localhost 0:0:0:1]# cat unique_id
600508B1001CE88B0746F381EEDF6577
It occurs to me that maybe something
like that would be useful for all disks serviced by the scsi mid layer. For example, kdump userland stuff, as typically implemented, has a very small ramdisk which it operates from, and has a fairly simple minded way of recognizing which disk is which (e.g. looks at vendor, model, rev, and type attributes, arguably not a very good way to do it, as just flashing firmware on a drive will change the rev, but won't mean the disk is not the same disk, for example, and likewise, all disks on a given Smart Array will carry the same vendor/model/rev/type, and type? Type is always going to be zero for a disk anyhow.)
So kdump needs some kind of a unique_id to help it out, but would prefer not to carry around e.g. sg_inq in the kdump initrd (so you may ask "stuffing it in the kernel is a better idea?") Well, _if_ the LLDs are typically already getting this info (as in the case of hpsa and cciss at least) maybe they should have some standard way of informing the mid layer, so the midlayer could expose this attribute in a standard way? Or, maybe the mid layer could send down the necessary inquiries to get the information itself with no interface changes needed?
Well, this seems like such an obvious idea, that the mere fact that it is not already implemented makes me think there may be some good reason why not.
-- steve
Quoted 65 lines · On 11-02-04 02:36 PM, [email protected] wrote:
Would it be a reasonable idea to add some sort of
unique_idattribute to scsi devices in the mid layer?For example,
sg_inq, fromsg3_utils, will print out a serial number:[root@localhost scameron]#
sg_inq/dev/sda
standard INQUIRY:PQual=0 Device_type=0 RMB=0 version=0x05 [SPC-3] [AERC=0] [TrmTsk=0] NormACA=0 HiSUP=0 Resp_data_format=2 SCCS=0 ACC=0 TPGS=0 3PC=0 Protect=0 BQue=0 EncServ=0 MultiP=0 [MChngr=0] [ACKREQQ=0] Addr16=0 [RelAdr=0] WBus16=0 Sync=0 Linked=0 [TranDis=0] CmdQue=1 length=56 (0x38) Peripheral device type: diskVendor identification: HP
Product identification: LOGICAL VOLUME
Product revision level: 3.66
Unit serial number: 50014380065020C0And there's also some stuff in page
0x83on some devices which might be useful as suck an identifier:[root@localhost scameron]#
sg_inq--page0x83/dev/sdaVPD INQUIRY: Device Identification page
Designation descriptor number 1, descriptor length: 20designator_type: NAA, code_set: Binary associated with the addressed logical unit NAA 6, IEEE Company_id: 0x508b Vendor Specific Identifier: 0x1001ce88b Vendor Specific Identifier Extension: 0x746f381eedf6577 [0x600508b1001ce88b0746f381eedf6577]Designation descriptor number 2, descriptor length: 8
designator_type: vendor specific [0x0],code_set: Binary associated with the addressed logical unit
00 00 00 00 00 ....
[root@localhost scameron]#The hpsa driver, for example, currently exports a "
unique_id" attribute itself for disks, which is the same data reported by inquire page0x83.[root@localhost 0:0:0:1]# pwd
/sys/bus/scsi/devices/0:0:0:1
[root@localhost 0:0:0:1]# catunique_id
600508B1001CE88B0746F381EEDF6577It occurs to me that maybe something
like that would be useful for all disks serviced by the scsi mid layer. For example, kdump userland stuff, as typically implemented, has a very small ramdisk which it operates from, and has a fairly simple minded way of recognizing which disk is which (e.g. looks at vendor, model, rev, and type attributes, arguably not a very good way to do it, as just flashing firmware on a drive will change the rev, but won't mean the disk is not the same disk, for example, and likewise, all disks on a given Smart Array will carry the same vendor/model/rev/type, and type? Type is always going to be zero for a disk anyhow.)So kdump needs some kind of a
unique_idto help it out, but would prefer not to carry around e.g.sg_inqin the kdump initrd (so you may ask "stuffing it in the kernel is a better idea?") Well, _if_ the LLDs are typically already getting this info (as in the case of hpsa and cciss at least) maybe they should have some standard way of informing the mid layer, so the midlayer could expose this attribute in a standard way? Or, maybe the mid layer could send down the necessary inquiries to get the information itself with no interface changes needed?
Quoted 3 lines
Well, this seems like such an obvious idea, that the mere fact that it is not already implemented makes me think there may be some good reason why not.
Yes, indeed :-)
The problem is those pesky little storage devices that (ab)use the SCSI command set (e.g. some USB keys). Some of them lock up when given anything other than a bog standard INQUIRY command requesting a 36 byte response with EVPD=0. After the lock up such devices typically need a power cycle to come back to life, then if the OS sends them the same command again that locked them up ... you probably get the idea.
Redmond seems to like globally unique identifiers (GUIDs) for storage devices, I wonder how they handle this problem. A heuristic based in the transport may be one approach.
Doug Gilbert
Quoted 81 lines · Douglas Gilbert
Quoted 65 lines · On 11-02-04 02:36 PM, [email protected] wrote:
Would it be a reasonable idea to add some sort of
unique_idattribute to scsi devices in the mid layer?For example,
sg_inq, fromsg3_utils, will print out a serial number:[root@localhost scameron]#
sg_inq/dev/sda
standard INQUIRY:PQual=0 Device_type=0 RMB=0 version=0x05 [SPC-3] [AERC=0] [TrmTsk=0] NormACA=0 HiSUP=0 Resp_data_format=2 SCCS=0 ACC=0 TPGS=0 3PC=0 Protect=0 BQue=0 EncServ=0 MultiP=0 [MChngr=0] [ACKREQQ=0] Addr16=0 [RelAdr=0] WBus16=0 Sync=0 Linked=0 [TranDis=0] CmdQue=1 length=56 (0x38) Peripheral device type: diskVendor identification: HP
Product identification: LOGICAL VOLUME
Product revision level: 3.66
Unit serial number: 50014380065020C0And there's also some stuff in page
0x83on some devices which might be useful as suck an identifier:[root@localhost scameron]#
sg_inq--page0x83/dev/sdaVPD INQUIRY: Device Identification page
Designation descriptor number 1, descriptor length: 20designator_type: NAA, code_set: Binary associated with the addressed logical unit NAA 6, IEEE Company_id: 0x508b Vendor Specific Identifier: 0x1001ce88b Vendor Specific Identifier Extension: 0x746f381eedf6577 [0x600508b1001ce88b0746f381eedf6577]Designation descriptor number 2, descriptor length: 8
designator_type: vendor specific [0x0],code_set: Binary associated with the addressed logical unit
00 00 00 00 00 ....
[root@localhost scameron]#The hpsa driver, for example, currently exports a "
unique_id" attribute itself for disks, which is the same data reported by inquire page0x83.[root@localhost 0:0:0:1]# pwd
/sys/bus/scsi/devices/0:0:0:1
[root@localhost 0:0:0:1]# catunique_id
600508B1001CE88B0746F381EEDF6577It occurs to me that maybe something
like that would be useful for all disks serviced by the scsi mid layer. For example, kdump userland stuff, as typically implemented, has a very small ramdisk which it operates from, and has a fairly simple minded way of recognizing which disk is which (e.g. looks at vendor, model, rev, and type attributes, arguably not a very good way to do it, as just flashing firmware on a drive will change the rev, but won't mean the disk is not the same disk, for example, and likewise, all disks on a given Smart Array will carry the same vendor/model/rev/type, and type? Type is always going to be zero for a disk anyhow.)So kdump needs some kind of a
unique_idto help it out, but would prefer not to carry around e.g.sg_inqin the kdump initrd (so you may ask "stuffing it in the kernel is a better idea?") Well, _if_ the LLDs are typically already getting this info (as in the case of hpsa and cciss at least) maybe they should have some standard way of informing the mid layer, so the midlayer could expose this attribute in a standard way? Or, maybe the mid layer could send down the necessary inquiries to get the information itself with no interface changes needed?Quoted 3 lines
Well, this seems like such an obvious idea, that the mere fact that it is not already implemented makes me think there may be some good reason why not.
Yes, indeed :-)
The problem is those pesky little storage devices that (ab)use the SCSI command set (e.g. some USB keys). Some of them lock up when given anything other than a bog standard INQUIRY command requesting a 36 byte response with EVPD=0. After the lock up such devices typically need a power cycle to come back to life, then if the OS sends them the same command again that locked them up ... you probably get the idea.
Quoted 4 lines
Redmond seems to like globally unique identifiers (GUIDs) for storage devices, I wonder how they handle this problem. A heuristic based in the transport may be one approach.
Main problem is that device do not exactly have _one_ unique ID, but rather several; check scsi_id to approve the real complexity here. So when adding this field we would actually move quite some bit of policy into the kernel.
The transport ID OTOH is well defined and actually used in some contexts (persistent reservation spring to mind here). Having that in sysfs would be great.
Cheers,
Hannes
Signature · 8 lines
Dr. Hannes Reinecke zSeries & Storage [email protected] +49 911 74053 688 SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg GF: Markus Rex, HRB 16746 (AG Nürnberg) -- To unsubscribe from this list: send the line "unsubscribe linux-scsi" in the body of a message to [email protected] More majordomo info at http://vger.kernel.org/majordomo-info.html