savagefb: Use panel CVT mode as default
Paul Mundt
AppliedQuoted 8 lines · Tormod Volden
From: Tormod Volden <[email protected]>
If there is no EDID but an LCD panel is detected, generate a CVT mode from the panel resolution (at 60 Hz), and use this as a default mode instead of the hardcoded 800x600x8 mode.
Signed-off-by Tormod Volden <[email protected]>
Applied, thanks.