be2net: fix to set ecmd->autoneg correctly
Subsystems (2)
PATCH 6/6 be2net: fix to set ecmd->autoneg correctly
Set the autonegotation settings correctly based on the port speed.
Signed-off-by Suresh Reddy <[email protected]>
Signed-off-by Ajit Khaparde <[email protected]>
--- drivers/net/benet/be_ethtool.c | 21 +++++++++++++++++---- 1 files changed, 17 insertions(+), 4 deletions(-)
drivers/net/benet/be_ethtool.c +17 -4
@@ -353,6 +353,8 @@ static int be_get_settings(struct net_device *netdev, struct ethtool_cmd *ecmd)u8 mac_speed =0 ;u16 link_speed =0 ;int status; +u16 port_speed =0 ; +u16 dac_cable_len =0 ;if ((adapter->link_speed <0 ) || (!(netdev->flags &IFF_UP ))) { status = be_cmd_link_status_query(adapter, &mac_speed,
@@ -397,11 +399,9 @@ static int be_get_settings(struct net_device *netdev, struct ethtool_cmd *ecmd)switch (phy_info.interface_type) {case PHY_TYPE_KR_10GB :case PHY_TYPE_KX4_10GB : - ecmd->autoneg =AUTONEG_ENABLE ; ecmd->transceiver =XCVR_INTERNAL ;break ;default : - ecmd->autoneg =AUTONEG_DISABLE ; ecmd->transceiver =XCVR_EXTERNAL ;break ; }
@@ -411,12 +411,25 @@ static int be_get_settings(struct net_device *netdev, struct ethtool_cmd *ecmd) adapter->link_speed =ethtool_cmd_speed (ecmd); adapter->port_type = ecmd->port; adapter->transceiver = ecmd->transceiver; - adapter->autoneg = ecmd->autoneg; }else {ethtool_cmd_speed_set (ecmd, adapter->link_speed); ecmd->port = adapter->port_type; ecmd->transceiver = adapter->transceiver; - ecmd->autoneg = adapter->autoneg; + } + +be_cmd_get_port_speed (adapter, adapter->port_num, + &dac_cable_len, &port_speed); +switch (port_speed) { +case SPEED_FORCED_10GB : +case SPEED_FORCED_1GB : +case SPEED_FORCED_100MB : +case SPEED_FORCED_10MB : +case SPEED_DEFAULT : + ecmd->autoneg =AUTONEG_DISABLE ; +break ; +default : + ecmd->autoneg =AUTONEG_ENABLE ; +break ; } ecmd->duplex =DUPLEX_FULL ;
Signature · 1 line
1.7.4.1
Quoted 1 line · Ajit Khaparde
Set the autonegotation settings correctly based on the port speed.
[...]
Autonegotiation and multi-speed are two entirely different things.
Selecting a single speed doesn't mean turning autoneg off. If you enable only 1000BASE-T or only 10GBASE-T, the PHY must still go through autoneg to determine whether it is the clock master for the link.
Enabling multiple speeds doesn't mean turning autoneg on. An SFP+ slot can take 1G and 10G modules but the modules generally won't support autoneg.
Ben.
Signature · 3 lines
Ben Hutchings, Staff Engineer, Solarflare Not speaking for my employer; that's the marketing department's job. They asked us to note that Solarflare product names are trademarked.