bnx2x: fix cl_id allocation for non-eth clients for NPAR mode
Subsystems (2)
PATCH 1/1 bnx2x: fix cl_id allocation for non-eth clients for NPAR mode
There are some consolidations of NPAR configuration when FCoE and iSCSI L2 clients will get the same id, in this case FCoE ring will be non-functional.
Signed-off-by Dmitry Kravkov <[email protected]>
Signed-off-by Eilon Greenstein <[email protected]>
--- drivers/net/bnx2x/bnx2x.h | 20 +++++++++++++------- drivers/net/bnx2x/bnx2x_cmn.h | 2 +- 2 files changed, 14 insertions(+), 8 deletions(-)
drivers/net/bnx2x/bnx2x.h +12 -6
@@ -239,13 +239,19 @@ void bnx2x_int_disable(struct bnx2x *bp);* FUNC_N_CLID_X = N * NUM_SPECIAL_CLIENTS + FUNC_0_CLID_X * */ -/* iSCSI L2 */ -#define BNX2X_ISCSI_ETH_CL_ID_IDX 1 -#define BNX2X_ISCSI_ETH_CID 49 +enum { +BNX2X_ISCSI_ETH_CL_ID_IDX , +BNX2X_FCOE_ETH_CL_ID_IDX , +BNX2X_MAX_CNIC_ETH_CL_ID_IDX , +}; -/* FCoE L2 */ -#define BNX2X_FCOE_ETH_CL_ID_IDX 2 -#define BNX2X_FCOE_ETH_CID 50 +#define BNX2X_CNIC_START_ETH_CID 48 +enum { +/* iSCSI L2 */ +BNX2X_ISCSI_ETH_CID =BNX2X_CNIC_START_ETH_CID , +/* FCoE L2 */ +BNX2X_FCOE_ETH_CID , +};/** Additional rings budgeting */ #ifdef BCM_CNIC
drivers/net/bnx2x/bnx2x_cmn.h +1 -1
@@ -1297,7 +1297,7 @@ static inline void bnx2x_init_txdata(struct bnx2x *bp,static inline u8 bnx2x_cnic_eth_cl_id (struct bnx2x *bp,u8 cl_idx) {return bp->cnic_base_cl_id + cl_idx + - (bp->pf_num >>1 ) *NON_ETH_CONTEXT_USE ; + (bp->pf_num >>1 ) *BNX2X_MAX_CNIC_ETH_CL_ID_IDX ; }static inline u8 bnx2x_cnic_fw_sb_id (struct bnx2x *bp)
Signature · 1 line
1.7.2.2
David Miller
maintainerFrom: "Dmitry Kravkov" <[email protected]>
Date: Mon, 10 Oct 2011 11:57:36 +0200
Quoted 6 lines
There are some consolidations of NPAR configuration when FCoE and iSCSI L2 clients will get the same id, in this case FCoE ring will be non-functional.
Signed-off-by Dmitry Kravkov <[email protected]>Signed-off-by Eilon Greenstein <[email protected]>
I'll apply this, thanks.