Skip to contentSkip to conversation

Copy machine descriptor after probe succeed

PATCH New [email protected] 2 participants 4 messages Dec 20, 2011 – Dec 21, 2011 PowerPC

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 Copy machine descriptor after probe succeed

This patch fix minor issue with machine probe process, It's much better to copy machine descriptor after probe succeed.

arch/powerpc/kernel/setup-common.c | 4 ++--

1 files changed, 2 insertions(+), 2 deletions(-
#1 lore raw

PATCH 1/1 Copy machine descriptor after probe succeed

From: Bill Carson <[email protected]>

It make more sense to copy machine descriptor AFTER machine probe return succeed.

---
 arch/powerpc/kernel/setup-common.c |    4 ++--
 1 files changed, 2 insertions(+), 2 deletions(-)
arch/powerpc/kernel/setup-common.c +2 -2
index d426b1d..3362097 100644
@@ -574,9 +574,9 @@ void probe_machine(void)
 	     machine_id < &__machine_desc_end;
 	     machine_id++) {
 		DBG("  %s ...", machine_id->name);
-		memcpy(&ppc_md, machine_id, sizeof(struct machdep_calls));
-		if (ppc_md.probe()) {
+		if (machine_id->probe()) {
 			DBG(" match !\n");
+			memcpy(&ppc_md, machine_id, sizeof(struct machdep_calls));
 			break;
 		}
 		DBG("\n");
Signature · 1 line
1.6.3.1
#2 lore raw

Hi Bill,

Quoted 5 lines · On Tue, 20 Dec 2011 17:08:47 +0800 [email protected] wrote:

From: Bill Carson <[email protected]>

It make more sense to copy machine descriptor AFTER machine probe return succeed.

Some of the platform's probe routines modify the ppc_md structure and so assume that it is has been popluated before the probe routine is called.

Signature · 3 lines
Cheers,
Stephen Rothwell                    [email protected]
http://www.canb.auug.org.au/~sfr/
#3 lore raw
Quoted 10 lines · Stephen Rothwell

Hi Bill,

Quoted 4 lines · On Tue, 20 Dec 2011 17:08:47 +0800 [email protected] wrote:

From: Bill Carson<[email protected]>

It make more sense to copy machine descriptor AFTER machine probe return succeed.

Some of the platform's probe routines modify the ppc_md structure and so assume that it is has been popluated before the probe routine is called.

I didn't see the whole picture before :(
thanks for your point.

Signature · 4 lines
I am a slow learner
but I will keep trying to fight for my dreams!

--bill