Skip to contentSkip to conversation

arm: omap4: allow disabling MPU local timer if 32K timer is enabled

PATCH New Ming Lei 2 participants 5 messages Feb 11, 2012

Subsystems (3)
lore
Share & tools
lore

Ming Lei

author
#0 lore raw

PATCH 1/1 arm: omap4: allow disabling MPU local timer if 32K timer is enabled

With 32K gp timer, tick can be driven and system can run well, so allow MPU local timer to be disabled if someone requires it, otherwise MPU local timer is always chosen as the default clock_event_device.

---
 arch/arm/mach-omap2/Kconfig |    2 +-
 1 files changed, 1 insertions(+), 1 deletions(-)
arch/arm/mach-omap2/Kconfig +1 -1
index d965da4..12cd602 100644
@@ -46,7 +46,7 @@ config ARCH_OMAP4
 	select CPU_V7
 	select ARM_GIC
 	select HAVE_SMP
-	select LOCAL_TIMERS if SMP
+	select LOCAL_TIMERS if (SMP && !OMAP_32K_TIMER)
 	select PL310_ERRATA_588369
 	select PL310_ERRATA_727915
 	select ARM_ERRATA_720789
Signature · 1 line
1.7.9
#1 lore raw

PATCH 1/1 arm: omap4: allow disabling MPU local timer if 32K timer is enabled

Quoted 3 lines · Ming Lei

With 32K gp timer, tick can be driven and system can run well, so allow MPU local timer to be disabled if someone requires it, otherwise MPU local timer is always chosen as the default clock_event_device.

The point being?

What if you want to use NO_HZ?

author
#2 lore raw

PATCH 1/1 arm: omap4: allow disabling MPU local timer if 32K timer is enabled

Quoted 6 lines · Russell King - ARM Linux
Quoted 3 lines · Ming Lei

With 32K gp timer, tick can be driven and system can run well, so allow MPU local timer to be disabled if someone requires it, otherwise MPU local timer is always chosen as the default clock_event_device.

The point being?

IMO, 32K gp timer may be more energy-saving than MPU local timer because gp timer has much less clock frequency and only half interrupts generated in tick mode compared with mpu local timer.

Quoted 2 lines

What if you want to use NO_HZ?

32K gp timer supports oneshot mode, so it should support NO_HZ. In my test .config, NO_HZ is enabled and system can run well.

thanks,

Signature · 1 line
Ming Lei
#3 lore raw

PATCH 1/1 arm: omap4: allow disabling MPU local timer if 32K timer is enabled

Quoted 14 lines · Ming Lei
Quoted 6 lines · Russell King - ARM Linux
Quoted 3 lines · Ming Lei

With 32K gp timer, tick can be driven and system can run well, so allow MPU local timer to be disabled if someone requires it, otherwise MPU local timer is always chosen as the default clock_event_device.

The point being?

IMO, 32K gp timer may be more energy-saving than MPU local timer because gp timer has much less clock frequency and only half interrupts generated in tick mode compared with mpu local timer.

Quoted 1 line
Quoted 4 lines
Quoted 1 line

What if you want to use NO_HZ?

32K gp timer supports oneshot mode, so it should support NO_HZ. In my test .config, NO_HZ is enabled and system can run well.

Have you actually checked the tick rate of your timer in /proc/interrupts? Have you checked /proc/timer_list to see what mode the system is in?

author
#4 lore raw

PATCH 1/1 arm: omap4: allow disabling MPU local timer if 32K timer is enabled

Quoted 2 lines · Russell King - ARM Linux

Have you actually checked the tick rate of your timer in /proc/interrupts? Have you checked /proc/timer_list to see what mode the system is in?

After checking, the system works at periodic mode, but I still don't know why it can't be in one shot mode.

Seems a single clock_event_device can't work well at system with more than one CPU, so the patch doesn't make sense, please ignore it.

thanks,

Signature · 1 line
Ming Lei