Skip to contentSkip to conversation

mpt2sas : Fix for With post diag reset same set of device gets added, removed and then again gets added with new target ids

PATCH New [email protected] 1 participant 1 message Jul 17, 2012 SCSI

lore
Share & tools
lore
#0 lore raw

PATCH 8/9 mpt2sas : Fix for With post diag reset same set of device gets added, removed and then again gets added with new target ids

When device discovery is disabled during driver load time using module parameter "disable_discovery=1" and when diag reset is issued then from logs, it is observed that the devices get added, removed and then added with new target ids.

So, inorder to limit this turn-off the code which is deleting and devices across host reset when the disable_discovery module parameter is turned on.

---

drivers/scsi/mpt2sas/mpt2sas_scsih.c +2 -1
index 7a69a5c..7efefb7 100644
@@ -7264,7 +7264,8 @@ mpt2sas_scsih_reset_handler(struct MPT2SAS_ADAPTER *ioc, int reset_phase)
 		_scsih_search_responding_sas_devices(ioc);
 		_scsih_search_responding_raid_devices(ioc);
 		_scsih_search_responding_expanders(ioc);
-		if (!ioc->is_driver_loading) {
+		if ((!ioc->is_driver_loading) && !(disable_discovery > 0 &&
+		    !ioc->sas_hba.num_phys)) {
 			_scsih_prep_device_scan(ioc);
 			_scsih_search_responding_sas_devices(ioc);
 			_scsih_search_responding_raid_devices(ioc);