Skip to contentSkip to conversation

hwmon/lm70: Adds support for LM71 and LM74

PATCH Applied Christophe Leroy 2 participants 2 messages Sep 4, 2012

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 2/2 hwmon/lm70: Adds support for LM71 and LM74

Adding support for LM74 and LM71 chips

drivers/hwmon/Kconfig +3 -3
diff -u linux-3.5-vanilla/drivers/hwmon/Kconfig linux-3.5/drivers/hwmon/Kconfig
@@ -530,12 +530,12 @@
 	  will be called lm63.
 
 config SENSORS_LM70
-	tristate "National Semiconductor LM70 / Texas Instruments TMP121"
+	tristate "National Semiconductor LM70 and compatibles"
 	depends on SPI_MASTER
 	help
 	  If you say yes here you get support for the National Semiconductor
-	  LM70 and Texas Instruments TMP121/TMP123 digital temperature
-	  sensor chips.
+	  LM70, LM71, LM74 and Texas Instruments TMP121/TMP123 digital tempera-
+	  ture sensor chips.
 
 	  This driver can also be built as a module.  If so, the module
 	  will be called lm70.
drivers/hwmon/lm70.c +22 -3
diff -u linux-3.5-vanilla/drivers/hwmon/lm70.c linux-3.5/drivers/hwmon/lm70.c
@@ -43,6 +43,8 @@
 
 #define LM70_CHIP_LM70		0	/* original NS LM70 */
 #define LM70_CHIP_TMP121	1	/* TI TMP121/TMP123 */
+#define LM70_CHIP_LM71		2	/* NS LM71 */
+#define LM70_CHIP_LM74		3	/* NS LM71 */
 
 struct lm70 {
 	struct device *hwmon_dev;
@@ -88,9 +90,13 @@
 	 * Celsius.
 	 * So it's equivalent to multiplying by 0.25 * 1000 = 250.
 	 *
-	 * TMP121/TMP123:
+	 * LM74 and TMP121/TMP123:
 	 * 13 bits of 2's complement data, discard LSB 3 bits,
 	 * resolution 0.0625 degrees celsius.
+	 *
+	 * LM71:
+	 * 14 bits of 2's complement data, discard LSB 2 bits,
+	 * resolution 0.0312 degrees celsius.
 	 */
 	switch (p_lm70->chip) {
 	case LM70_CHIP_LM70:
@@ -98,8 +104,13 @@
 		break;
 
 	case LM70_CHIP_TMP121:
+	case LM70_CHIP_LM74:
 		val = ((int)raw / 8) * 625 / 10;
 		break;
+
+	case LM70_CHIP_LM71:
+		val = ((int)raw / 4) * 3125 / 100;
+		break;
 	}
 
 	status = sprintf(buf, "%d\n", val); /* millidegrees Celsius */
@@ -123,6 +134,12 @@
 	case LM70_CHIP_TMP121:
 		ret = sprintf(buf, "tmp121\n");
 		break;
+	case LM71_CHIP_LM71:
+		ret = sprintf(buf, "lm71\n");
+		break;
+	case LM74_CHIP_LM74:
+		ret = sprintf(buf, "lm74\n");
+		break;
 	default:
 		ret = -EINVAL;
 	}
@@ -139,7 +156,7 @@
 	struct lm70 *p_lm70;
 	int status;
 
-	/* signaling is SPI_MODE_0 for both LM70 and TMP121 */
+	/* signaling is SPI_MODE_0 */
 	if (spi->mode & (SPI_CPOL | SPI_CPHA))
 		return -EINVAL;
 
@@ -198,6 +215,8 @@
 static const struct spi_device_id lm70_ids[] = {
 	{ "lm70",   LM70_CHIP_LM70 },
 	{ "tmp121", LM70_CHIP_TMP121 },
+	{ "lm71", LM70_CHIP_LM71 },
+	{ "lm74", LM70_CHIP_LM74 },
 	{ },
 };
 MODULE_DEVICE_TABLE(spi, lm70_ids);
@@ -215,5 +234,5 @@
 module_spi_driver(lm70_driver);
 
 MODULE_AUTHOR("Kaiwan N Billimoria");
-MODULE_DESCRIPTION("NS LM70 / TI TMP121/TMP123 Linux driver");
+MODULE_DESCRIPTION("NS LM70 and compatibles Linux driver");
 MODULE_LICENSE("GPL");
Documentation/hwmon/lm70 +8 -1
diff -u linux-3.5-vanilla/Documentation/hwmon/lm70 linux-3.5/Documentation/hwmon/lm70
@@ -6,6 +6,10 @@
     Datasheet: http://www.national.com/pf/LM/LM70.html
   * Texas Instruments TMP121/TMP123
     Information: http://focus.ti.com/docs/prod/folders/print/tmp121.html
+  * National Semiconductor LM71
+    Datasheet: http://www.ti.com/product/LM71
+  * National Semiconductor LM74
+    Datasheet: http://www.ti.com/product/LM74
 
 Author:
         Kaiwan N Billimoria <[email protected]>
@@ -31,9 +35,12 @@
 with a "SPI master controller driver", see drivers/spi/spi_lm70llp.c
 and its associated documentation.
 
-The TMP121/TMP123 are very similar; main difference is 13-bit temperature
+The LM74 and TMP121/TMP123 are very similar; main difference is 13-bit temperature
 data (0.0625 degrees celsius resolution).
 
+The LM71 is also very similar; main difference is 14-bit temperature
+data (0.03125 degrees celsius resolution).
+
 Thanks to
 ---------
 Jean Delvare <[email protected]> for mentoring the hwmon-side driver

_______________________________________________
lm-sensors mailing list
[email protected]
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors

maintainer
#1 lore raw
Quoted 4 lines · Christophe Leroy

Adding support for LM74 and LM71 chips

Hi Christophe,

couple of comments below.

Quoted 23 lines

diff -u linux-3.5-vanilla/drivers/hwmon/Kconfig linux-3.5/drivers/hwmon/Kconfig

drivers/hwmon/Kconfig +3 -3
@@ -530,12 +530,12 @@
 	  will be called lm63.
 
 config SENSORS_LM70
-	tristate "National Semiconductor LM70 / Texas Instruments TMP121"
+	tristate "National Semiconductor LM70 and compatibles"
 	depends on SPI_MASTER
 	help
 	  If you say yes here you get support for the National Semiconductor
-	  LM70 and Texas Instruments TMP121/TMP123 digital temperature
-	  sensor chips.
+	  LM70, LM71, LM74 and Texas Instruments TMP121/TMP123 digital tempera-
+	  ture sensor chips.
 
 	  This driver can also be built as a module.  If so, the module
 	  will be called lm70.

diff -u linux-3.5-vanilla/drivers/hwmon/lm70.c linux-3.5/drivers/hwmon/lm70.c

drivers/hwmon/lm70.c line 48

Quoted 6 lines
drivers/hwmon/lm70.c +2 -0
@@ -43,6 +43,8 @@
 
 #define LM70_CHIP_LM70		0	/* original NS LM70 */
 #define LM70_CHIP_TMP121	1	/* TI TMP121/TMP123 */
+#define LM70_CHIP_LM71		2	/* NS LM71 */
+#define LM70_CHIP_LM74		3	/* NS LM71 */
 
	NS LM71 -> NS LM74
Quoted 32 lines
drivers/hwmon/lm70.c +10 -1
 struct lm70 {
 	struct device *hwmon_dev;
@@ -88,9 +90,13 @@
 	 * Celsius.
 	 * So it's equivalent to multiplying by 0.25 * 1000 = 250.
 	 *
-	 * TMP121/TMP123:
+	 * LM74 and TMP121/TMP123:
 	 * 13 bits of 2's complement data, discard LSB 3 bits,
 	 * resolution 0.0625 degrees celsius.
+	 *
+	 * LM71:
+	 * 14 bits of 2's complement data, discard LSB 2 bits,
+	 * resolution 0.0312 degrees celsius.
 	 */
 	switch (p_lm70->chip) {
 	case LM70_CHIP_LM70:
@@ -98,8 +104,13 @@
 		break;
 
 	case LM70_CHIP_TMP121:
+	case LM70_CHIP_LM74:
 		val = ((int)raw / 8) * 625 / 10;
 		break;
+
+	case LM70_CHIP_LM71:
+		val = ((int)raw / 4) * 3125 / 100;
+		break;
 	}
 
 	status = sprintf(buf, "%d\n", val); /* millidegrees Celsius */

drivers/hwmon/lm70.c line 142

Quoted 9 lines
drivers/hwmon/lm70.c +6 -0
@@ -123,6 +134,12 @@
 	case LM70_CHIP_TMP121:
 		ret = sprintf(buf, "tmp121\n");
 		break;
+	case LM71_CHIP_LM71:
+		ret = sprintf(buf, "lm71\n");
+		break;
+	case LM74_CHIP_LM74:
+		ret = sprintf(buf, "lm74\n");
+		break;

Please make sure to at least compile your code ... the above doesn't compile.

Quoted 13 lines
drivers/hwmon/lm70.c +1 -1
 	default:
 		ret = -EINVAL;
 	}
@@ -139,7 +156,7 @@
 	struct lm70 *p_lm70;
 	int status;
 
-	/* signaling is SPI_MODE_0 for both LM70 and TMP121 */
+	/* signaling is SPI_MODE_0 */
 	if (spi->mode & (SPI_CPOL | SPI_CPHA))
 		return -EINVAL;
 

drivers/hwmon/lm70.c line 219

Quoted 5 lines
drivers/hwmon/lm70.c +2 -0
@@ -198,6 +215,8 @@
 static const struct spi_device_id lm70_ids[] = {
 	{ "lm70",   LM70_CHIP_LM70 },
 	{ "tmp121", LM70_CHIP_TMP121 },
+	{ "lm71", LM70_CHIP_LM71 },
+	{ "lm74", LM70_CHIP_LM74 },

Please align LM70_xxx to the first two lines.

Quoted 25 lines
drivers/hwmon/lm70.c +1 -1
 	{ },
 };
 MODULE_DEVICE_TABLE(spi, lm70_ids);
@@ -215,5 +234,5 @@
 module_spi_driver(lm70_driver);
 
 MODULE_AUTHOR("Kaiwan N Billimoria");
-MODULE_DESCRIPTION("NS LM70 / TI TMP121/TMP123 Linux driver");
+MODULE_DESCRIPTION("NS LM70 and compatibles Linux driver");
 MODULE_LICENSE("GPL");

diff -u linux-3.5-vanilla/Documentation/hwmon/lm70 linux-3.5/Documentation/hwmon/lm70

Documentation/hwmon/lm70 +4 -0
@@ -6,6 +6,10 @@
     Datasheet: http://www.national.com/pf/LM/LM70.html
   * Texas Instruments TMP121/TMP123
     Information: http://focus.ti.com/docs/prod/folders/print/tmp121.html
+  * National Semiconductor LM71
+    Datasheet: http://www.ti.com/product/LM71
+  * National Semiconductor LM74
+    Datasheet: http://www.ti.com/product/LM74
 
 Author:
         Kaiwan N Billimoria <[email protected]>

Documentation/hwmon/lm70 line 38

Quoted 5 lines
Documentation/hwmon/lm70 +1 -1
@@ -31,9 +35,12 @@
 with a "SPI master controller driver", see drivers/spi/spi_lm70llp.c
 and its associated documentation.
 
-The TMP121/TMP123 are very similar; main difference is 13-bit temperature
+The LM74 and TMP121/TMP123 are very similar; main difference is 13-bit temperature

Please move the last word to the next line to keep the line length at 80 columns.

Thanks,
Guenter

Quoted 9 lines
Documentation/hwmon/lm70 +3 -0
 data (0.0625 degrees celsius resolution).
 
+The LM71 is also very similar; main difference is 14-bit temperature
+data (0.03125 degrees celsius resolution).
+
 Thanks to
 ---------
 Jean Delvare <[email protected]> for mentoring the hwmon-side driver