issues with adjusting the crushmap in 0.51
Hi All,
I've been playing around with 0.51 of ceph on two test machines in work, I was experimenting with adjusting the crushmap to change from replicating across osd's to replicating across hosts. When I change the rule for my data pool from type osd to type host, compile up the crushmap and then a "ceph osd setcrushmap -i crush.new" it crashes my monitor if I have one running, if I have two, then one of them crashes and the process just hangs and leaves my test filesystem in an unclean state.
I changed the rule data {} to this
rule data {
ruleset 0
type replicated
min_size 1
max_size 10
step take default
step choose firstn 0 type host
step emit
}
Are there any constraints for changing the rules on where things get replicated? i.e. to go from osd to host to rack with the data and metadata?
Here's my ceph.conf file and crushmap before the changes
[global]
#auth supported = cephx
#keyring = /etc/ceph/ceph.keyring
filestore xattr use omap = true
[osd]
osd journal size = 1000
filestore xattr use omap = true
[mon.a]
host = 134.226.112.194
mon addr = 134.226.112.194:6789
mon data = /data/mon.$id
[mon.b]
host = 134.226.112.138
mon addr = 134.226.112.138:6789
mon data = /home/mon.$id[mds.a]
host = 134.226.112.194
mon data = /data/mds.$id
[mds.b]
host = 134.226.112.138
mon data = /home/mds.$id
[osd.0]
host = 134.226.112.194
osd data = /data/osd.$id
osd journal = /data/osd.$id.journal
[osd.1]
host = 134.226.112.194
osd data = /data$id/osd.$id
osd journal = /data$id/osd.$id.journal
[osd.2]
host = 134.226.112.138
osd data = /home/osd.$id
osd journal = /home/osd.$id.journal
My crushmap
# begin crush map
# devices device 0 osd.0 device 1 osd.1 device 2 osd.2
# types type 0 osd type 1 host type 2 rack type 3 row type 4 room type 5 datacenter type 6 pool
# buckets
host 134.226.112.194 {
id -2 # do not change unnecessarily
# weight 2.000
alg straw
hash 0 # rjenkins1
item osd.1 weight 1.000
item osd.0 weight 1.000
}
host 134.226.112.138 {
id -4 # do not change unnecessarily
# weight 1.000
alg straw
hash 0 # rjenkins1
item osd.2 weight 1.000
}
rack rack-1 {
id -3 # do not change unnecessarily
# weight 3.000
alg straw
hash 0 # rjenkins1
item 134.226.112.194 weight 2.000
item 134.226.112.138 weight 1.000
}
pool default {
id -1 # do not change unnecessarily
# weight 2.000
alg straw
hash 0 # rjenkins1
item rack-1 weight 2.000
}# rules
rule data {
ruleset 0
type replicated
min_size 1
max_size 10
step take default
step choose firstn 0 type osd
step emit
}rule metadata {
ruleset 1
type replicated
min_size 1
max_size 10
step take default
step choose firstn 0 type osd
step emit
}
rule rbd {
ruleset 2
type replicated
min_size 1
max_size 10
step take default
step choose firstn 0 type osd
step emit
}
Jimmy
Signature · 4 lines
Jimmy Tang Trinity Centre for High Performance Computing, Lloyd Building, Trinity College Dublin, Dublin 2, Ireland. http://www.tchpc.tcd.ie/
Quoted 23 lines · Jimmy Tang
Hi All,
I've been playing around with 0.51 of ceph on two test machines in work, I was experimenting with adjusting the crushmap to change from replicating across osd's to replicating across hosts. When I change the rule for my data pool from type osd to type host, compile up the crushmap and then a "ceph osd setcrushmap -i crush.new" it crashes my monitor if I have one running, if I have two, then one of them crashes and the process just hangs and leaves my test filesystem in an unclean state.
I changed the rule data {} to this
rule data {
ruleset 0
type replicated
min_size1
max_size10
step take default
step choose firstn 0 type host
step emit
}
Quoted 3 lines
Are there any constraints for changing the rules on where things get replicated? i.e. to go from osd to host to rack with the data and metadata?
You always need to end up with "devices" (the OSDs, generally) and then emit those from your CRUSH rule. You can do so hierarchically:
rule data {
ruleset 0
type replicated
min_size 1
max_size 10
step take default
step choose firstn 0 type host
step choose firstn 1 osd
step emit
}
In this case, (with n being your replication count) this rule chooses n hosts, and then chooses 1 OSD from each chosen host.
You can also use "chooseleaf", which is a bit more robust in the presence of failed OSDs:
rule data {
ruleset 0
type replicated
min_size 1
max_size 10
step take default
step chooseleaf firstn 0 type host
step emit
}
This rule will choose n hosts and an OSD from each chosen host, and if it fails on any host then it will restart with a different host (the previous rule would stick with the chosen hosts and so it can't handle if eg an entire host's OSDs are down).
-Greg
Hi Greg
Quoted 15 lines · Gregory Farnum
You always need to end up with "devices" (the OSDs, generally) and then emit those from your CRUSH rule. You can do so hierarchically:
rule data {
ruleset 0
type replicated
min_size1
max_size10
step take default
step choose firstn 0 type host
step choose firstn 1 osd
step emit
}
In this case, (with n being your replication count) this rule chooses n hosts, and then chooses 1 OSD from each chosen host.
Quoted 17 lines
You can also use "chooseleaf", which is a bit more robust in the presence of failed OSDs:
rule data {
ruleset 0
type replicated
min_size1
max_size10
step take default
step chooseleaf firstn 0 type host
step emit
}
This rule will choose n hosts and an OSD from each chosen host, and if it fails on any host then it will restart with a different host (the previous rule would stick with the chosen hosts and so it can't handle if eg an entire host's OSDs are down).
-Greg
That explaination certainly has cleared things up for me, I had not realised that I needed to end with a "device" at the end of a rule based on the documentation that I could find on the website and the old ceph wiki.
Also, the "ceph osd setcrushmap..." command doesn't up when a ceph --help is run in the 0.51 release, however it is documented on the wiki as far as I recall. It'd be real nice if the applications emitted all the available commands, it would make experimenting much nicer and fun.
Thanks,
Jimmy,
Signature · 4 lines
Jimmy Tang Trinity Centre for High Performance Computing, Lloyd Building, Trinity College Dublin, Dublin 2, Ireland. http://www.tchpc.tcd.ie/
Quoted 5 lines · Jimmy Tang
Also, the "ceph osd setcrushmap..." command doesn't up when a ceph --help is run in the 0.51 release, however it is documented on the wiki as far as I recall. It'd be real nice if the applications emitted all the available commands, it would make experimenting much nicer and fun.
"ceph" is just a client app that sends (most of) the commands to ceph-mon for execution; it's --help is problematic to keep up to date.. We're trying to do better. Patches appreciated, see ticket at the end..
Background:
http://www.spinics.net/lists/ceph-devel/msg08471.html
http://www.spinics.net/lists/ceph-devel/msg08472.html
http://www.tracker.newdream.net/issues/2894
Quoted 12 lines · Tommi Virtanen
Quoted 5 lines · Jimmy Tang
Also, the "ceph osd setcrushmap..." command doesn't up when a ceph --help is run in the 0.51 release, however it is documented on the wiki as far as I recall. It'd be real nice if the applications emitted all the available commands, it would make experimenting much nicer and fun.
"ceph" is just a client app that sends (most of) the commands to ceph-mon for execution; it's --help is problematic to keep up to date.. We're trying to do better. Patches appreciated, see ticket at the end..
Quoted 5 lines
Background:
http://www.spinics.net/lists/ceph-devel/msg08471.html
http://www.spinics.net/lists/ceph-devel/msg08472.html
http://www.tracker.newdream.net/issues/2894
I was just looking at that, there's a few places where I have noticed to have in-accurate "help" messages. I will go over my notes and see if I can provide a few patches.
Jimmy
Signature · 4 lines
Jimmy Tang Trinity Centre for High Performance Computing, Lloyd Building, Trinity College Dublin, Dublin 2, Ireland. http://www.tchpc.tcd.ie/
Hi Tommi.
Quoted 11 lines · Tommi Virtanen
Quoted 5 lines · Jimmy Tang
Also, the "ceph osd setcrushmap..." command doesn't up when a ceph --help is run in the 0.51 release, however it is documented on the wiki as far as I recall. It'd be real nice if the applications emitted all the available commands, it would make experimenting much nicer and fun.
"ceph" is just a client app that sends (most of) the commands to ceph-mon for execution; it's --help is problematic to keep up to date.. We're trying to do better. Patches appreciated, see ticket at the end..
Just to scratch an itch, here's some documentation additions from testing locally,
[jtang@x00 ceph (master)]$ git diff
doc/cluster-ops/control.rst +4 -0
@@ -293,6 +293,10 @@ Enables debug messages. :: Displays the status of all metadata servers. +Make a pool usable by the fs with:: + + ceph mds add_data_pool {pool-name} + .. todo:: ``ceph mds`` subcommands missing docs: set_max_mds, dump, getmap, stop, setmap
src/tools/ceph.cc +2 -0
@@ -62,6 +62,7 @@ static void usage() cout << "\n"; cout << "METADATA SERVER (MDS) COMMANDS\n"; cout << " ceph mds stat\n"; + cout << " ceph mds add_data_pool <pool>\n"; cout << " ceph mds tell <mds-id or *> injectargs '--<switch> <value> [--<switch> <value>...]'\n"; cout << "\n"; cout << "MONITOR (MON) COMMANDS\n";
@@ -82,6 +83,7 @@ static void usage() cout << " ceph osd unpause\n"; cout << " ceph osd tell <osd-id or *> injectargs '--<switch> <value> [--<switch> <value>...]'\n"; cout << " ceph osd getcrushmap -o <file>\n"; + cout << " ceph osd setcrushmap -i <file>\n"; cout << " ceph osd getmap -o <file>\n"; cout << " ceph osd crush set <osd-id> <weight> <loc1> [<loc2> ...]\n"; cout << " ceph osd crush move <bucketname> <loc1> [<loc2> ...]\n";
Regards,
Jimmy Tang
--
Senior Software Engineer, Digital Repository of Ireland (DRI) Trinity Centre for High Performance Computing, Lloyd Building, Trinity College Dublin, Dublin 2, Ireland.