Skip to contentSkip to conversation

serial: pl011: safeguard against impossible baudrates

PATCH New Linus Walleij 3 participants 3 messages Sep 20, 2012 – Sep 21, 2012

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/3 serial: pl011: safeguard against impossible baudrates

From: Linus Walleij <[email protected]>

The PL011 generates it's bitrate from the clock to the block, and this in turn will be divided by a minimum of 16 (ARM PL011) or 8 (ST Micro PL011 derivate). Safeguard against illegal rates exceeding that of what the port clock can be divided down to.

Since the clkdiv variable is only ever used for calculating the maximum baud rate, let's skip that variable and add a new max_baud variable instead, then use this to check limits and as parameter for getting the baud rate.

Cc Par-Gunnar Hjalmdahl <[email protected]>
Cc Guillaume Jaunet <[email protected]>
Cc Christophe Arnal <[email protected]>
Cc Matthias Locher <[email protected]>
Cc Rajanikanth H.V <[email protected]>
---
 drivers/tty/serial/amba-pl011.c | 15 +++++++++++----
 1 file changed, 11 insertions(+), 4 deletions(-)
drivers/tty/serial/amba-pl011.c +11 -4
index d626d84..9e16ea6 100644
@@ -1492,18 +1492,25 @@ pl011_set_termios(struct uart_port *port, struct ktermios *termios,
 	struct uart_amba_port *uap = (struct uart_amba_port *)port;
 	unsigned int lcr_h, old_cr;
 	unsigned long flags;
-	unsigned int baud, quot, clkdiv;
+	unsigned int max_baud, baud, quot;
 
 	if (uap->vendor->oversampling)
-		clkdiv = 8;
+		max_baud = port->uartclk / 8;
 	else
-		clkdiv = 16;
+		max_baud = port->uartclk / 16;
+
+	if ((termios->c_ispeed > max_baud) ||
+	    (termios->c_ospeed > max_baud)) {
+		dev_err(port->dev,
+			"requested a baud rate > clock/mindivisor\n");
+		return;
+	}
 
 	/*
 	 * Ask the core to calculate the divisor for us.
 	 */
 	baud = uart_get_baud_rate(port, termios, old, 0,
-				  port->uartclk / clkdiv);
+				  max_baud);
 
 	if (baud > port->uartclk/16)
 		quot = DIV_ROUND_CLOSEST(port->uartclk * 8, baud);
Signature · 1 line
1.7.11.3
#1 lore raw

PATCH 1/3 serial: pl011: safeguard against impossible baudrates

drivers/tty/serial/amba-pl011.c pl011_set_termios(struct uart_port *port, struct ktermios *termios, · line 1507

Quoted 6 lines · Linus Walleij
drivers/tty/serial/amba-pl011.c +6 -0
+	if ((termios->c_ispeed > max_baud) ||
+	    (termios->c_ospeed > max_baud)) {
+		dev_err(port->dev,
+			"requested a baud rate > clock/mindivisor\n");
+		return;
+	}

Why do we need this check? In any case, this is incorrect behaviour just to 'return' from this function without doing anything. You just produce an error message, and userspace believes that it's request has been satisfied.

uart_get_baud_rate() is there precisely to do the right thing for invalid baud rates, which is to fallback to the old termios setting (and update the new termios with that) if the old termios setting satisifies the limits, if not it falls back to something within the limited range.

#2 lore raw

PATCH 1/3 serial: pl011: safeguard against impossible baudrates

Quoted 4 lines · Russell King - ARM Linux

uart_get_baud_rate() is there precisely to do the right thing for invalid baud rates, which is to fallback to the old termios setting (and update the new termios with that) if the old termios setting satisifies the limits, if not it falls back to something within the limited range.

Yeah, hm, passing 4800000 as max rate to this function and requesting 4050000 returns 4000000... (Other high baud rates such as 3250000 or 3000000 works fine) so there is some fishy bug in there we're just duct-taping around, I'll go hunt the real bug instead.

Thanks!