Hi Paul, Tony,

how do you guys want to handle PWM's Time Base clocks which are enabled via control module ?

They're controlled via offset 0x664 (pwmss_ctrl). Page 793 of AM33xx's TRM has more information:

"
Table 9-42. pwmss_ctrl Register Field Descriptions

Bit Field Type Reset Description
31-3 Reserved R 0h
2 pwmss2_tbclken R/W 0h Timebase clock enable for PWMSS2
1 pwmss1_tbclken R/W 0h Timebase clock enable for PWMSS1
0 pwmss0_tbclken R/W 0h Timebase clock enable for PWMSS0
"

We don't have clock nodes for those, but they're needed to have functioning pwm drivers.

cheers

Signature · 1 line
balbi
#1 lore raw

+Avinash

Quoted 8 lines · Felipe

Hi Paul, Tony,

how do you guys want to handle PWM's Time Base clocks which are enabled via control module ?

They're controlled via offset 0x664 (pwmss_ctrl). Page 793 of AM33xx's TRM has more information:

Avinash has already posted the patch for this https://lkml.org/lkml/2013/2/12/43

Regards,
Vaibhav