AM33xx's PWM Time Base Clock Enable signals
Hi Paul, Tony,
how do you guys want to handle PWM's Time Base clocks which are enabled via control module ?
They're controlled via offset 0x664 (pwmss_ctrl). Page 793 of AM33xx's TRM has more information:
"
Table 9-42. pwmss_ctrl Register Field Descriptions
Bit Field Type Reset Description
31-3 Reserved R 0h
2 pwmss2_tbclken R/W 0h Timebase clock enable for PWMSS2
1 pwmss1_tbclken R/W 0h Timebase clock enable for PWMSS1
0 pwmss0_tbclken R/W 0h Timebase clock enable for PWMSS0
"
We don't have clock nodes for those, but they're needed to have functioning pwm drivers.
cheers
Signature · 1 line
balbi
+Avinash
Quoted 8 lines · Felipe
Hi Paul, Tony,
how do you guys want to handle PWM's Time Base clocks which are enabled via control module ?
They're controlled via offset
0x664(pwmss_ctrl). Page 793 of AM33xx's TRM has more information:
Avinash has already posted the patch for this https://lkml.org/lkml/2013/2/12/43
Regards,
Vaibhav
Hi,
Quoted 5 lines · Vaibhav
+Avinash
Quoted 2 lines · Felipe
Hi Paul, Tony,
Quoted 8 lines
Quoted 6 lines
how do you guys want to handle PWM's Time Base clocks which are enabled via control module ?
They're controlled via offset
0x664(pwmss_ctrl). Page 793 of AM33xx's TRM has more information:Avinash has already posted the patch for this https://lkml.org/lkml/2013/2/12/43
thanks ;-)
Signature · 1 line
balbi