carl9170: monitor mode hangs due to channel changes
Hello,
I'm seeing a problem with the carl driver. If I change channels repeatedly on the 2.4ghz band, monitoring (e.g. tcpdump) will eventually halt. I've seen this on various versions of the carl driver/firmware (both from 1.9.4 to 1.9.7)
After monitoring has hung, changing to a 5ghz channel, causes monitoring to resume. Bouncing the interface (ip link set mon0 down/up) also fixes it.
Here are some steps to reproduce:
# setup interface
iw wlan0 interface add mon0 type monitor
ip link set mon0 up # start channging channels
while true ; do for i in 1 6 11 ; do iw mon0 set channel $i ; \
sleep .250 ; done ; doneIn a second terminal:
tcpdump -i mon0
Wait until tcpdump stops printing. I've seen the failure rate vary greatly, sometime minutes, sometime hours, but usually less then an hour.
Regards,
Marco Fonseca
Christian Lamparter
maintainerHello,
Quoted 4 lines · Marco Fonseca
I'm seeing a problem with the carl driver. If I change channels repeatedly on the 2.4ghz band, monitoring (e.g. tcpdump) will eventually halt. I've seen this on various versions of the carl driver/firmware (both from 1.9.4 to 1.9.7)
thanks for reporting this. You could try either of the attached patch and test if it alleviate the issue. If the patches do help then the problem is caused by rf/phy (code) [which is a problem since the rf/phy parts are taken from the vendor driver as we have no docs or specs for it].
Regards,
Chr
--
Patch 1: just reinitialize AGC_CONTROL
(can also be moved behind CMD_FREQ_START)
---
drivers/net/wireless/ath/carl9170/phy.c +7 -0
@@ -1638,6 +1638,13 @@ int carl9170_set_channel(struct ar9170 *ar, struct ieee80211_channel *channel, cmd =CARL9170_CMD_FREQUENCY ; } + err =carl9170_write_reg (ar,AR9170_PHY_REG_AGC_CONTROL , +carl9170_def_val (AR9170_PHY_REG_AGC_CONTROL , + channel->band ==IEEE80211_BAND_2GHZ , +conf_is_ht40 (&ar->hw->conf))); +if (err) +return err; + err =carl9170_exec_cmd (ar,CARL9170_CMD_FREQ_START ,0 ,NULL ,0 ,NULL );if (err)return err;
---
Patch 2: always do warm reset when changing channels
---
drivers/net/wireless/ath/carl9170/phy.c +1 -8
@@ -1578,7 +1578,7 @@ int carl9170_set_channel(struct ar9170 *ar, struct ieee80211_channel *channel,u32 cmd, tmp, offs =0 , new_ht =0 ;int err;enum carl9170_bw bw; -bool warm_reset; +bool warm_reset = true;struct ieee80211_channel *old_channel =NULL ; bw =nl80211_to_carl (_bw);
@@ -1592,14 +1592,7 @@ int carl9170_set_channel(struct ar9170 *ar, struct ieee80211_channel *channel,/* may be NULL at first setup */ if (ar->channel) { old_channel = ar->channel; - warm_reset = (old_channel->band != channel->band) || - (old_channel->center_freq == - channel->center_freq) || - (ar->ht_settings != new_ht); - ar->channel =NULL ; - }else { - warm_reset = true; }/* HW workaround */
---
As far as I can tell those patches fixed it. I wasn't paying attention and applied both patches though. My environment is a little different today and I will test some more on Monday.
If you think it would help, I can test the patches individually.
Thanks!
Marco
Quoted 15 lines · Christian Lamparter
Hello,
Quoted 4 lines · Marco Fonseca
I'm seeing a problem with the carl driver. If I change channels repeatedly on the 2.4ghz band, monitoring (e.g. tcpdump) will eventually halt. I've seen this on various versions of the carl driver/firmware (both from 1.9.4 to 1.9.7)
thanks for reporting this. You could try either of the attached patch and test if it alleviate the issue. If the patches do help then the problem is caused by rf/phy (code) [which is a problem since the rf/phy parts are taken from the vendor driver as we have no docs or specs for it].
Regards,
Chr
Christian Lamparter
maintainerQuoted 3 lines · On Saturday 23 March 2013 21:00:38 you wrote:
As far as I can tell those patches fixed it. I wasn't paying attention and applied both patches though. My environment is a little different today and I will test some more on Monday.
No worries. I can wait for the test results on Monday.
Quoted 1 line
If you think it would help, I can test the patches individually.
Yes. The second patch disables the "fast channel change" feature. And this should be avoided, unless of course it is absolutely necessary.
Regards,
Chr