PATCH 4/5 pwmconfig: Properly deal with multiple fan control

When a given PWM output controls more than one fan, fanactive_min is no longer a space-separated list of numbers, it will also include items of the form "A+B". The tests in the rest of the code do not expect that and choke with errors like:

/usr/sbin/pwmconfig: line 926: [: 538+799: integer expression expected /usr/sbin/pwmconfig: line 952: [: 538+799: integer expression expected

As the only thing we really care about is whether any fan stops completely when PWM is 0, we can simply record the minimum of the lowest speed of all affected fans.

---
 prog/pwm/pwmconfig |   13 +++++++++++--
 1 file changed, 11 insertions(+), 2 deletions(-)
prog/pwm/pwmconfig +11 -2
@@ -444,6 +444,7 @@ do
 
 	let pwmactivecount=0
 	let count=1
+	S_MIN 	for j in $GOODFAN
 	do
 		OS=`echo $SPEEDS | cut -d' ' -f$count`
@@ -462,7 +463,6 @@ do
 				let pwmactivecount=1
 				pwmactive="$i ${pwmactive}"
 				fanactive="$j ${fanactive}"
-				fanactive_min="$S ${fanactive_min}"
 
 				# Give all correlated fans time to return to full speed
 				sleep $DELAY
@@ -473,8 +473,14 @@ do
 				fi
 			else
 				fanactive="$j+${fanactive}"
-				fanactive_min="$S+${fanactive_min}"
 			fi
+
+			# Keep track of the slowest fan controlled by one PWM
+			if [ -z "$S_MIN" ] || [ $S -lt $S_MIN ]
+			then
+				S_MIN=$S
+			fi
+
 			S=`cat $j`
 			if [ $S -lt $threshold ]
 			then
@@ -507,8 +513,11 @@ do
 		if [ "$X" = "y" -o "$X" = "Y" ]
 		then
 			pwmactive="$i ${pwmactive}"
+			fanactive_min="0 $fanactive_min"
 		fi
 		echo
+	else
+		fanactive_min="$S_MIN $fanactive_min"
 	fi
 done
 