How to identify a failed md array
Hello,
I am wondering how to identify a failed md array.
Lets assume the following array
/dev/md0:
Version : 1.2
Creation Time : Mon May 26 19:10:59 2014
Raid Level : raid1
Array Size : 10176 (9.94 MiB 10.42 MB)
Used Dev Size : 10176 (9.94 MiB 10.42 MB)
Raid Devices : 2
Total Devices : 2
Persistence : Superblock is persistent
Update Time : Mon May 26 19:10:59 2014
State : clean
Active Devices : 2
Working Devices : 2
Failed Devices : 0
Spare Devices : 0
Name : test:0 (local to host test) UUID : cac8fd48:44219a96:5de7e757:4e21a3e2
Events : 17
Number Major Minor RaidDevice State
0 254 0 0 active sync /dev/dm-0
1 254 1 1 active sync /dev/dm-1
with
/sys/block/md0/md/array_state:clean
/sys/block/md0/md/dev-dm-0/state:in_sync
/sys/block/md0/md/dev-dm-1/state:in_sync
and
disk0: 0 20480 linear 7:0 0
disk1: 0 20480 linear 7:1 0
If dm-0 gets changed to "disk0: 0 20480 error" and we read from the array (dd if=/dev/md0 count=1 iflag=direct of=/dev/null) the broken disk gets detected by md:
[84688.483607] md/raid1:md0: dm-0: rescheduling sector 0 [84688.483654] md/raid1:md0: redirecting sector 0 to other mirror: dm-1 [84688.483670] md: super_written gets error=-5, uptodate=0 [84688.483672] md/raid1:md0: Disk failure on dm-0, disabling device. md/raid1:md0: Operation continuing on 1 devices. [84688.483676] md: super_written gets error=-5, uptodate=0 [84688.494174] RAID1 conf printout: [84688.494178] --- wd:1 rd:2 [84688.494181] disk 0, wo:1, o:0, dev:dm-0 [84688.494182] disk 1, wo:0, o:1, dev:dm-1 [84688.494183] RAID1 conf printout: [84688.494184] --- wd:1 rd:2 [84688.494184] disk 1, wo:0, o:1, dev:dm-1
/dev/md0:
Version : 1.2
Creation Time : Mon May 26 19:10:59 2014
Raid Level : raid1
Array Size : 10176 (9.94 MiB 10.42 MB)
Used Dev Size : 10176 (9.94 MiB 10.42 MB)
Raid Devices : 2
Total Devices : 2
Persistence : Superblock is persistent
Update Time : Mon May 26 19:27:41 2014
State : clean, degraded
Active Devices : 1
Working Devices : 1
Failed Devices : 1
Spare Devices : 0
Name : test:0 (local to host test) UUID : cac8fd48:44219a96:5de7e757:4e21a3e2
Events : 20
Number Major Minor RaidDevice State
0 0 0 0 removed
1 254 1 1 active sync /dev/dm-1
0 254 0 - faulty /dev/dm-0
md0 : active raid1 dm-1[1] dm-0[0](F)
10176 blocks super 1.2 [2/1] [_U]
/sys/block/md0/md/array_state:clean /sys/block/md0/md/dev-dm-0/state:faulty,write_error /sys/block/md0/md/dev-dm-1/state:in_sync /sys/block/md0/md/degraded:1
However if I also change dm-1 to "disk1: 0 20480 error" and read again there is no visible state change:
/dev/md0:
Version : 1.2
Creation Time : Mon May 26 19:10:59 2014
Raid Level : raid1
Array Size : 10176 (9.94 MiB 10.42 MB)
Used Dev Size : 10176 (9.94 MiB 10.42 MB)
Raid Devices : 2
Total Devices : 2
Persistence : Superblock is persistent
Update Time : Mon May 26 19:27:41 2014
State : clean, degraded
Active Devices : 1
Working Devices : 1
Failed Devices : 1
Spare Devices : 0
Number Major Minor RaidDevice State
0 0 0 0 removed
1 254 1 1 active sync /dev/dm-1
0 254 0 - faulty /dev/dm-0
md0 : active raid1 dm-1[1] dm-0[0](F)
10176 blocks super 1.2 [2/1] [_U]
/sys/block/md0/md/array_state:clean /sys/block/md0/md/dev-dm-0/state:faulty,write_error /sys/block/md0/md/dev-dm-1/state:in_sync /sys/block/md0/md/degraded:1
On write to the array we get
[85498.660247] md: super_written gets error=-5, uptodate=0 [85498.666464] quiet_error: 268 callbacks suppressed [85498.666470] Buffer I/O error on device md0, logical block 2528 [85498.666476] Buffer I/O error on device md0, logical block 2528 [85498.666486] Buffer I/O error on device md0, logical block 2542 [85498.666490] Buffer I/O error on device md0, logical block 2542 [85498.666496] Buffer I/O error on device md0, logical block 0 [85498.666499] Buffer I/O error on device md0, logical block 0 [85498.666508] Buffer I/O error on device md0, logical block 1 [85498.666512] Buffer I/O error on device md0, logical block 1 [85498.666518] Buffer I/O error on device md0, logical block 2543 [85498.666524] Buffer I/O error on device md0, logical block 2543 [85498.866388] md: super_written gets error=-5, uptodate=0
and the only change is
/sys/block/md0/md/dev-dm-1/state:in_sync,write_error,want_replacement
How can I identify a failed array?array_state reports "clean", the last raid member stays "in_sync" and the value in degraded doesn't equal raid_disks.
Sebastian
Quoted 144 lines · On Mon, 26 May 2014 20:07:11 +0200 Sebastian Herbszt <[email protected]> wrote:
Hello,
I am wondering how to identify a failed md array.
Lets assume the following array
/dev/md0:Version : 1.2Creation Time : Mon May 26 19:10:59 2014
Raid Level : raid1
Array Size : 10176 (9.94 MiB 10.42 MB)
Used Dev Size : 10176 (9.94 MiB 10.42 MB)
Raid Devices : 2
Total Devices : 2
Persistence : Superblock is persistentUpdate Time : Mon May 26 19:10:59 2014
State : clean
Active Devices : 2
Working Devices : 2
Failed Devices : 0
Spare Devices : 0Name : test:0 (local to host test) UUID : cac8fd48:44219a96:5de7e757:4e21a3e2
Events : 17Number Major Minor RaidDevice State
0 254 0 0 active sync/dev/dm-0
1 254 1 1 active sync/dev/dm-1with
/sys/block/md0/md/array_state:clean
/sys/block/md0/md/dev-dm-0/state:in_sync
/sys/block/md0/md/dev-dm-1/state:in_syncand
disk0: 0 20480 linear 7:0 0
disk1: 0 20480 linear 7:1 0If dm-0 gets changed to "disk0: 0 20480 error" and we read from the array (dd if=/dev/md0 count=1 iflag=direct of=/dev/null) the broken disk gets detected by md:
[84688.483607] md/raid1:md0: dm-0: rescheduling sector 0 [84688.483654] md/raid1:md0: redirecting sector 0 to other mirror: dm-1 [84688.483670] md: super_written gets error=-5, uptodate=0 [84688.483672] md/raid1:md0: Disk failure on dm-0, disabling device. md/raid1:md0: Operation continuing on 1 devices. [84688.483676] md: super_written gets error=-5, uptodate=0 [84688.494174] RAID1 conf printout: [84688.494178] --- wd:1 rd:2 [84688.494181] disk 0, wo:1, o:0, dev:dm-0 [84688.494182] disk 1, wo:0, o:1, dev:dm-1 [84688.494183] RAID1 conf printout: [84688.494184] --- wd:1 rd:2 [84688.494184] disk 1, wo:0, o:1, dev:dm-1
/dev/md0:Version : 1.2Creation Time : Mon May 26 19:10:59 2014
Raid Level : raid1
Array Size : 10176 (9.94 MiB 10.42 MB)
Used Dev Size : 10176 (9.94 MiB 10.42 MB)
Raid Devices : 2
Total Devices : 2
Persistence : Superblock is persistentUpdate Time : Mon May 26 19:27:41 2014
State : clean, degraded
Active Devices : 1
Working Devices : 1
Failed Devices : 1
Spare Devices : 0Name : test:0 (local to host test) UUID : cac8fd48:44219a96:5de7e757:4e21a3e2
Events : 20Number Major Minor RaidDevice State
0 0 0 0 removed
1 254 1 1 active sync/dev/dm-10 254 0 - faulty
/dev/dm-0md0 : active raid1 dm-1[1] dm-0[0](F)
10176 blocks super 1.2 [2/1] [_U]/sys/block/md0/md/array_state:clean /sys/block/md0/md/dev-dm-0/state:faulty,write_error /sys/block/md0/md/dev-dm-1/state:in_sync
/sys/block/md0/md/degraded:1However if I also change dm-1 to "disk1: 0 20480 error" and read again there is no visible state change:
/dev/md0:Version : 1.2Creation Time : Mon May 26 19:10:59 2014
Raid Level : raid1
Array Size : 10176 (9.94 MiB 10.42 MB)
Used Dev Size : 10176 (9.94 MiB 10.42 MB)
Raid Devices : 2
Total Devices : 2
Persistence : Superblock is persistentUpdate Time : Mon May 26 19:27:41 2014
State : clean, degraded
Active Devices : 1
Working Devices : 1
Failed Devices : 1
Spare Devices : 0Number Major Minor RaidDevice State
0 0 0 0 removed
1 254 1 1 active sync/dev/dm-10 254 0 - faulty
/dev/dm-0md0 : active raid1 dm-1[1] dm-0[0](F)
10176 blocks super 1.2 [2/1] [_U]/sys/block/md0/md/array_state:clean /sys/block/md0/md/dev-dm-0/state:faulty,write_error /sys/block/md0/md/dev-dm-1/state:in_sync
/sys/block/md0/md/degraded:1On write to the array we get
[85498.660247] md: super_written gets error=-5, uptodate=0 [85498.666464] quiet_error: 268 callbacks suppressed [85498.666470] Buffer I/O error on device md0, logical block 2528 [85498.666476] Buffer I/O error on device md0, logical block 2528 [85498.666486] Buffer I/O error on device md0, logical block 2542 [85498.666490] Buffer I/O error on device md0, logical block 2542 [85498.666496] Buffer I/O error on device md0, logical block 0 [85498.666499] Buffer I/O error on device md0, logical block 0 [85498.666508] Buffer I/O error on device md0, logical block 1 [85498.666512] Buffer I/O error on device md0, logical block 1 [85498.666518] Buffer I/O error on device md0, logical block 2543 [85498.666524] Buffer I/O error on device md0, logical block 2543 [85498.866388] md: super_written gets error=-5, uptodate=0
Quoted 7 lines
and the only change is
/sys/block/md0/md/dev-dm-1/state:in_sync,write_error,want_replacement
How can I identify a failed array?
array_statereports "clean", the last raid member stays "in_sync" and the value in degraded doesn't equalraid_disks.
You know the array is "failed" when you get an IO error.
When a RAID1 array gets down to just one drive remaining, it starts acting like it is just one drive.
How do you tell if is single plain ordinary drive is failed? You get an IO error. ditto with RAID1.
NeilBrown
Quoted 3 lines · NeilBrown
On Mon, 26 May 2014 20:07:11 +0200 Sebastian Herbszt <[email protected]> wrote:
[snip]
Quoted 4 lines
Quoted 3 lines
How can I identify a failed array?
array_statereports "clean", the last raid member stays "in_sync" and the value in degraded doesn't equalraid_disks.
Quoted 9 lines
You know the array is "failed" when you get an IO error.
When a RAID1 array gets down to just one drive remaining, it starts acting like it is just one drive.
How do you tell if is single plain ordinary drive is failed? You get an IO error. ditto with RAID1.NeilBrown
Since md knows the current state I hoped it would provide the required information for an application to distinguish between degraded and failed arrays. Any reason this is not the case?
This would allow mdadm to not only report "DegradedArray" but also "FailedArray". Currently it does not generate any event when the last drive fails.
Sebastian
Quoted 21 lines · On Sun, 1 Jun 2014 19:23:39 +0200 Sebastian Herbszt <[email protected]> wrote:
Quoted 3 lines · NeilBrown
On Mon, 26 May 2014 20:07:11 +0200 Sebastian Herbszt <[email protected]> wrote:
[snip]
Quoted 4 lines
Quoted 3 lines
How can I identify a failed array?
array_statereports "clean", the last raid member stays "in_sync" and the value in degraded doesn't equalraid_disks.Quoted 9 lines
You know the array is "failed" when you get an IO error.
When a RAID1 array gets down to just one drive remaining, it starts acting like it is just one drive.
How do you tell if is single plain ordinary drive is failed? You get an IO error. ditto with RAID1.NeilBrown
Quoted 7 lines
Since md knows the current state I hoped it would provide the required information for an application to distinguish between degraded and failed arrays. Any reason this is not the case?
This would allow mdadm to not only report "DegradedArray" but also "FailedArray". Currently it does not generate any event when the last drive fails.
But md *doesn't* know the current state.
There is no state for "this device has failed".
There is only 'an IO request has failed' or 'this device has been removed'.
'an IO request has failed' does not necessarily mean that the device has failed - sometimes that is a very important difference.
NeilBrown